光谱光子计数X线摄影鉴别关节病相关晶体:一项概念验证研究
该概念验证研究在体外用光谱光子计数X线摄影(SPCR)扫描焦磷酸钙、羟基磷灰石(HA)和单钠尿酸盐(MSU)校准棒,并与临床双能CT(DECT)验证对比,发现不同浓度和不同材料的衰减与有效原子序数(Zeff)差异均有统计学意义(P<0.001),SPCR与DECT的Zeff定量测量无显著差异(P=0.054-0.412);在一例慢性痛风患者离体第三趾中,SPCR光谱分解可显示MSU沉积的性质与范围,并依据Zeff将其与骨HA区分。作者结论为SPCR有望以与DECT相当的诊断准确度识别和鉴别关节病相关晶体,但尚需进一步研究评估体内诊断准确度和临床可用性。
要点
- SPCR可在体外依据Zeff区分焦磷酸钙、羟基磷灰石和单钠尿酸盐,不同材料间差异P<0.001。
- SPCR与DECT的Zeff定量测量无显著差异(P=0.054-0.412),提示两者诊断准确度可能相当。
- 在离体痛风趾中,常规灰度X线可见痛风性骨侵蚀,SPCR光谱分解可显示MSU沉积性质与范围并与骨HA区分。
核心结论
- SPCR可在体外识别和区分关节病相关不同晶体,其诊断准确度与DECT相当。
- 在离体痛风人第三趾中,SPCR光谱分解可揭示MSU沉积的性质和范围,并依据Zeff将其与骨HA分离。
- 作者指出尚需进一步研究评估体内诊断准确度和临床可用性。
研究设计与样本
- 概念验证研究,体外使用焦磷酸钙、羟基磷灰石(HA)和单钠尿酸盐(MSU)的工业标准校准棒,每种材料3种不同浓度。
- 采用专用光子计数探测器行SPCR扫描,并在临床双能CT(DECT)扫描仪上获取验证扫描。
- 在SPCR图像及连续DECT图像上放置感兴趣区,测量包括有效原子序数(Zeff)在内的X线衰减特征。
- 对一例慢性痛风性关节炎患者的离体第三趾行SPCR和DECT扫描,以区分MSU与HA。
关键影像表现/征象
- 在离体痛风趾的常规灰度X线图像上可见痛风性骨侵蚀。
- SPCR光谱图像分解可显示MSU沉积的性质和范围,并依据Zeff将其与骨HA分离。
诊断标准与关键数值
- SPCR和DECT中,不同浓度间及不同材料间的衰减和Zeff值差异均有统计学意义(P<0.001)。
- SPCR与DECT来源的Zeff定量测量总体无显著差异(P=0.054-0.412)。
临床应用与阅片要点
- 在离体痛风趾中,常规灰度X线仅显示骨侵蚀,SPCR光谱分解可进一步显示MSU沉积的性质和范围。
- SPCR可依据Zeff将MSU与骨HA区分,与DECT的Zeff定量测量无显著差异。
- 作者指出尚需进一步研究评估SPCR的体内诊断准确度和临床可用性。
局限性
- 原文结论指出尚需进一步研究评估体内诊断准确度和临床可用性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aims of this study were to test whether spectral photon-counting radiography (SPCR) is able to identify and distinguish different crystals associated with arthropathies in vitro and to validate findings in a gouty human third toe ex vivo.
MATERIALS AND METHODS: Industry-standard calibration rods of calcium pyrophosphate, calcium hydroxyapatite (HA), and monosodium urate (MSU) were scanned with SPCR in an experimental setup. Each material was available at 3 different concentrations, and a dedicated photon-counting detector was used for SPCR, whereas validation scans were obtained on a clinical dual-energy computed tomography (DECT) scanner. Regions of interest were placed on SPCR images and consecutive DECT images to measure x-ray attenuation characteristics, including effective atomic numbers (Zeff). Statistical tests were performed for differentiation of Zeff between concentrations, materials, and imaging modalities. In addition, a third toe from a patient with chronic gouty arthritis was scanned with SPCR and DECT for differentiation of MSU from HA.
RESULTS: In both SPCR and DECT, significant differences in attenuation and Zeff values were found for different concentrations among (P < 0.001) and between different materials (P < 0.001). Overall, quantitative measurements of Zeff did not differ significantly between SPCR- and DECT-derived measurements (P = 0.054-0.412). In the human cadaver toe, gouty bone erosions were visible on standard grayscale radiographic images; however, spectral image decomposition revealed the nature and extent of MSU deposits and was able to separate it from bone HA by Zeff.
CONCLUSIONS: Identification and differentiation of different crystals related to arthropathies are possible with SPCR at comparable diagnostic accuracy to DECT. Further research is needed to assess diagnostic accuracy and clinical usability in vivo.
引用
- Huber FA, Becce F, Gkoumas S, et al. Differentiation of Crystals Associated With Arthropathies by Spectral Photon-Counting Radiography: A Proof-of-Concept Study. Invest Radiol. 2021. PMID: 32852444. doi:10.1097/RLI.0000000000000717
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。