对比增强视频透视与平扫动态MRI在腭咽功能障碍术后未成年患者中的比较
这项IRB批准的前瞻性研究纳入21例腭咽功能障碍术后儿童和青少年,对比平扫3-T动态MRI与对比增强视频透视在评估软腭与咽后壁间隙大小及图像质量方面的表现。两种方法在识别持续或复发性腭咽闭合不全方面效果相当,间隙测量差异无统计学意义(MRI 4.1±1.5 mm vs 视频透视 3.9±1.6 mm,p=0.5),但MRI主观整体图像质量评分低于视频透视(p<0.001)。作者认为动态MRI可作为一种无辐射的替代选择。
要点
- 平扫3-T动态MRI与对比增强视频透视识别腭咽闭合不全术后持续或复发病例的能力相当。
- MRI测量软腭-咽后壁间隙为4.1±1.5 mm,视频透视为3.9±1.6 mm,差异无统计学意义(p=0.5)。
- MRI主观整体图像质量评分低于视频透视(p<0.001),但磁化率伪影未限制解剖测量。
核心结论
- 动态MRI与视频透视在评估腭咽功能障碍术后持续或复发性腭帆闭合不全方面同样可靠。
- 平扫3-T动态MRI与对比增强视频透视在识别发音时腭咽闭合不全患者方面同样有用。
- MRI可作为一种无辐射的替代选择用于年轻患者。
研究设计与样本
- IRB批准的前瞻性研究,纳入21例腭咽功能障碍术后儿童和青少年,均接受平扫3-T MRI和对比增强视频透视检查。
- MRI方案包括发音时横断面和矢状面重聚焦梯度回波序列,TE 1.97 ms、TR 3.95 ms、翻转角8°、矩阵128×128、层厚5 mm。
- 采用径向k空间采样和滑动窗重建,图像采集速率达28帧/秒;视频透视同样在横断面和矢状面进行,帧率30帧/秒。
- 由两名经验丰富的放射科医生评估发音时腭咽门闭合情况。
关键影像表现/征象
- 11例(52.4%)患者显示完全闭合,10例(47.6%)患者发音时显示术后间隙。
- 视频透视与MRI对持续或复发性腭咽功能障碍的识别结果一致。
- MRI主观整体图像质量评分低于视频透视(p<0.001),两名评估者间一致性几乎完美(κ=0.90)。
- 磁化率伪影的存在未限制解剖测量。
诊断标准与关键数值
- 以发音时腭咽门闭合情况为评估对象,视频透视与MRI均识别出持续或复发性腭咽功能障碍病例。
- 软腭-咽后壁距离:视频透视3.9±1.6 mm vs MRI 4.1±1.5 mm,差异无统计学意义(p=0.5)。
临床应用与阅片要点
- 动态MRI可用于评估腭咽功能障碍术后儿童和青少年发音时腭咽闭合情况,识别持续或复发性闭合不全。
- MRI主观图像质量低于视频透视,阅片时应考虑这一差异。
- 磁化率伪影虽存在但未影响解剖测量,测量软腭-咽后壁距离时无需因伪影而放弃。
- 作者认为MRI可为年轻患者提供无辐射的替代选择。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare dynamic magnetic resonance imaging (MRI) with videofluoroscopy (VFS) regarding image quality and assessment of gap size between soft palate (SP) and posterior pharyngeal wall (PPW) in children and adolescents following surgical correction of velopharyngeal dysfunction (VPD).
METHODS: Twenty-one patients undergoing unenhanced 3-T MRI and contrast-enhanced VFS were included in this IRB-approved prospective study. The MRI scan protocol comprised refocused gradient-echo sequences in transverse and sagittal planes during speech, with TE 1.97 ms, TR 3.95 ms, flip angle 8°, matrix size 128 × 128, and 5-mm slice thickness. Radial k-space sampling and sliding window reconstruction were used to achieve an image acquisition rate of 28 frames per second (fps). VFS with 30 fps was similarly performed in both planes. Closure of the velopharyngeal port during phonation was evaluated by two experienced radiologists.
RESULTS: Eleven (52.4%) patients displayed a complete closure, whereas ten (47.6%) patients showed a post-operative gap during speech. VFS and MRI equally identified the cases with persistent or recurrent VPD. Differences in SP-PPW distance between VFS (3.9 ± 1.6 mm) and MRI (4.1 ± 1.5 mm) were not statistically significant (p = 0.5). The subjective overall image quality of MRI was rated inferior (p < 0.001) compared with VFS, with almost perfect inter-rater agreement (κ = 0.90). The presence of susceptibility artifacts did not limit anatomical measurements.
CONCLUSION: Dynamic MRI is equally reliable as VFS to assess persistent or recurrent inadequate velum closure in patients following surgical treatment of VPD.
KEY POINTS: • Unenhanced 3-T dynamic MRI and contrast-enhanced videofluoroscopy are equally useful for the identification of patients with incomplete velopharyngeal closure during speech. • MRI using refocused gradient-echo acquisition with radial k-space sampling and sliding window reconstruction generates diagnostic images with 28 frames per second. • MRI can offer a radiation-free alternative to currently established videofluoroscopy for young patients.
引用
- Arendt CT, Eichler K, Mack MG, et al. Comparison of contrast-enhanced videofluoroscopy to unenhanced dynamic MRI in minor patients following surgical correction of velopharyngeal dysfunction. Eur Radiol. 2020. PMID: 32740819. doi:10.1007/s00330-020-07098-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。