颈动脉超声检测与鉴别横窦/乙状窦及海绵窦硬脑膜动静脉瘘:枕动脉评估的重要性
回顾性纳入2014至2018年本院26例横窦/乙状窦或海绵窦硬脑膜动静脉瘘患者,比较颈动脉超声血流参数。横窦/乙状窦组颈外动脉舒张末期流速显著高于海绵窦组(P=.004),枕动脉舒张末期流速亦显著升高(P<.001);枕动脉舒张末期流速升高可预测横窦/乙状窦硬脑膜动静脉瘘。
要点
- 横窦/乙状窦硬脑膜动静脉瘘的供血以枕动脉为主,海绵窦瘘供血来自颈内动脉及脑膜中动脉硬膜支。
- 横窦/乙状窦瘘组颈外动脉舒张末期流速显著高于海绵窦瘘组(P=.004)。
- 横窦/乙状窦瘘组枕动脉舒张末期流速显著高于海绵窦瘘组(P<.001),可预测横窦/乙状窦瘘。
关键影像表现/征象
- 全部26例均评估同侧颈外动脉流速,其中20例评估枕动脉流速。
- 横窦/乙状窦硬脑膜动静脉瘘18例(女11例、男7例;平均年龄±标准差65.3±18.6岁),海绵窦硬脑膜动静脉瘘8例(女7例、男1例;平均年龄70.4±9.3岁)。
- 脑血管造影供血动脉评估显示,海绵窦瘘全部有颈内动脉及脑膜中动脉的硬膜支作为供血动脉。
- 脑血管造影供血动脉评估显示,枕动脉为全部横窦/乙状窦瘘病例的主要供血来源。
诊断标准与关键数值
- 横窦/乙状窦瘘组颈外动脉舒张末期流速显著高于海绵窦瘘组(P=.004)。
- 横窦/乙状窦瘘组枕动脉舒张末期流速显著高于海绵窦瘘组(P<.001),枕动脉舒张末期流速升高可预测横窦/乙状窦硬脑膜动静脉瘘。
临床应用与阅片要点
- 颈动脉超声评估硬脑膜动静脉瘘时,除颈外动脉外应评估枕动脉流速,枕动脉舒张末期流速升高提示横窦/乙状窦硬脑膜动静脉瘘。
- 颈外动脉与枕动脉舒张末期流速在横窦/乙状窦瘘与海绵窦瘘间存在显著差异,可用于两者鉴别。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Dural arteriovenous fistula (DAVFs) in the transverse sinus (TS)/sigmoid sinus (SS) and cavernous sinus (CS) are observed frequently in the clinic. This study aimed to detect DAVFs with ultrasound and compare carotid ultrasound findings between these conditions.
METHODS: We retrospectively reviewed 26 patients with either a TS/SS DAVF or a CS DAVF who were admitted to our hospital for evaluation of DAVFs from 2014 to 2018. The shunt site decision was made by neuroendovascular experts, whereas carotid ultrasound examinations were performed by ultrasound specialists. The flow velocity of the ipsilateral external carotid artery was reviewed in all 26 patients, whereas that of the occipital artery (OA) was examined in 20 patients. Blood flow velocities were compared between the TS/SS DAVF and CS DAVF groups.
RESULTS: The study included 18 patients with a TS/SS DAVF (11 women and 7 men; mean age ± SD, 65.3 ± 18.6 years) and 8 patients with a CS DAVF (7 women and 1 man; mean age, 70.4 ± 9.3 years). Evaluations of feeder arteries on cerebral angiography showed that all patients had dural branches from the internal carotid and middle meningeal arteries as feeders of CS DAVFs, whereas the OA was the major feeder source of all TS/SS DAVF cases. The end-diastolic velocity (EDV) of the external carotid artery was significantly higher in patients with a TS/SS DAVF compared with those with a CS DAVF (P = .004). The EDV of the OA was significantly elevated in TS/SS DAVF cases compared with CS DAVF cases (P < .001).
CONCLUSIONS: Duplex ultrasound parameters are significantly different between patients with TS/SS and CS DAVFs. An increased EDV of the OA can predict the presence of a TS/SS DAVF.
引用
- Hisaeda E, Shimada H, Ogata T, et al. Detection and Differentiation of Dural Arteriovenous Fistulas in the Transverse Sinus/Sigmoid Sinus and Cavernous Sinus Using Carotid Ultrasound: Importance of Evaluation of the Occipital Artery. J Ultrasound Med. 2020. PMID: 32833229. doi:10.1002/jum.15438
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。