使用深度学习在3 T下加速膝关节MRI:可互换性研究结果
研究优化基于变分网络的深度学习重建模型,对108例患者数据回顾性欠采样至净3.49倍加速(较标准2倍并行采集加速1.88倍),由6名读者比较临床图像与DL加速图像对膝关节内部紊乱的检出能力;结果显示两者可互换性高,任何评估特征出现不一致临床意见的比例不超过4%,且6名读者均认为加速序列质量优于临床序列。
要点
- DL加速膝关节MRI与标准图像在检出膝关节内部紊乱方面可互换,任何特征的不一致意见不超过4%。
- 6名读者均判定DL加速序列图像质量优于标准临床序列。
- 加速对应净3.49倍全采样数据采集加速,较标准2倍并行采集加速1.88倍。
核心结论
- 优化的DL模型可加速膝关节图像采集,在检出膝关节内部紊乱方面与标准图像表现可互换,且读者更偏好加速图像的质量。
研究设计与样本
- 可互换性研究,对108例患者数据回顾性欠采样,训练采用多序列专用训练策略的单重建模型,比较6名读者对临床图像与DL加速图像检出膝关节内部紊乱的能力。
- DL模型为使用变分网络的图像重建模型,训练数据来自不同对比和方向的多序列。
- 欠采样方式对应净3.49倍全采样数据采集加速,较标准2倍加速并行采集加速1.88倍。
诊断标准与关键数值
- 标准图像与DL加速图像之间可互换性高,任何评估特征互换序列产生不一致临床意见的比例不超过4%。
- 6名读者均判定加速序列图像质量优于临床序列。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. Deep learning (DL) image reconstruction has the potential to disrupt the current state of MRI by significantly decreasing the time required for MRI examinations. Our goal was to use DL to accelerate MRI to allow a 5-minute comprehensive examination of the knee without compromising image quality or diagnostic accuracy. MATERIALS AND METHODS. A DL model for image reconstruction using a variational network was optimized. The model was trained using dedicated multisequence training, in which a single reconstruction model was trained with data from multiple sequences with different contrast and orientations. After training, data from 108 patients were retrospectively undersampled in a manner that would correspond with a net 3.49-fold acceleration of fully sampled data acquisition and a 1.88-fold acceleration compared with our standard twofold accelerated parallel acquisition. An interchangeability study was performed, in which the ability of six readers to detect internal derangement of the knee was compared for clinical and DL-accelerated images. RESULTS. We found a high degree of interchangeability between standard and DL-accelerated images. In particular, results showed that interchanging the sequences would produce discordant clinical opinions no more than 4% of the time for any feature evaluated. Moreover, the accelerated sequence was judged by all six readers to have better quality than the clinical sequence. CONCLUSION. An optimized DL model allowed acceleration of knee images that performed interchangeably with standard images for detection of internal derangement of the knee. Importantly, readers preferred the quality of accelerated images to that of standard clinical images.
引用
- Recht MP, Zbontar J, Sodickson DK, et al. Using Deep Learning to Accelerate Knee MRI at 3 T: Results of an Interchangeability Study. AJR Am J Roentgenol. 2020. PMID: 32755163. doi:10.2214/AJR.20.23313
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。