文献速递骨肌MR

前瞻性人工智能图像质量增强的定量多对比5分钟膝关节MRI诊断准确性

Diagnostic Accuracy of Quantitative Multicontrast 5-Minute Knee MRI Using Prospective Artificial Intelligence Image Quality Enhancement.
PubMed 文献 · AJR Am J Roentgenol · 2020-08-05

51例膝痛患者行常规膝关节MRI及附加的5分钟3D定量双回波稳态(qDESS)序列,qDESS经前瞻性深度学习超分辨率将层分辨率提高一倍并自动生成T2图。常规MRI与qDESS评估所有组织的一致率为92%,κ=0.79(95%CI 0.76-0.81)。在43例接受关节镜的患者中,两者对软骨、半月板、韧带和滑膜的敏感度与特异度无显著差异(p=.23至>.99)。

要点

  • 常规MRI与5分钟qDESS评估所有组织的一致率为92%,κ=0.79(95%CI 0.76-0.81)。
  • 在43例关节镜患者中,常规MRI与qDESS对软骨、半月板、韧带和滑膜的诊断性能无显著差异。
  • qDESS自动生成的T2图可提高软骨异常的敏感度。

核心结论

  • 经前瞻性深度学习增强的qDESS与常规膝关节MRI读者间一致性强,对关节镜所见诊断性能接近等效。
  • qDESS能自动生成T2图,提高对软骨异常的敏感度。

研究设计与样本

  • 研究纳入51例膝关节疼痛患者,行膝关节MRI包括附加的3D qDESS序列并自动生成T2图。
  • qDESS经傅里叶插值后行前瞻性深度学习超分辨率,将层分辨率提高一倍。
  • 一名肌肉骨骼放射科医师和一名放射科住院医师独立回顾性评估常规MRI上的关节软骨、半月板、韧带、骨、伸膝装置和滑膜;经2个月洗脱期后,读者单独评估qDESS图像,随后评估qDESS加自动T2图。
  • 以关节镜手术所见为参考标准,比较常规MRI、单独qDESS和qDESS加T2图的敏感度与特异度,采用精确McNemar检验。

关键影像表现/征象

  • 常规MRI与qDESS评估所有组织的一致率为92%,所有影像表现的κ=0.79(95%CI 0.76-0.81)。

诊断标准与关键数值

  • 在43例接受关节镜的患者中,常规MRI(敏感度58-93%、特异度27-87%)与单独qDESS(敏感度54-90%、特异度23-91%)对软骨、半月板、韧带和滑膜的敏感度与特异度无显著差异(p=.23至>.99)。
  • 1级软骨病变:常规MRI敏感度33%、特异度56%;单独qDESS敏感度23%、特异度53%(p=.81);qDESS加T2图敏感度46%、特异度39%(p=.80)。
  • 2A级软骨病变:常规MRI敏感度27%、特异度53%;单独qDESS敏感度26%、特异度52%(p=.02);qDESS加T2图敏感度58%、特异度40%(p<.001)。

临床应用与阅片要点

  • 使用前瞻性人工智能增强qDESS图像质量可能有助于实现简略膝关节MRI方案,同时生成定量T2图。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Potential approaches for abbreviated knee MRI, including prospective acceleration with deep learning, have achieved limited clinical implementation. OBJECTIVE. The objective of this study was to evaluate the interreader agreement between conventional knee MRI and a 5-minute 3D quantitative double-echo steady-state (qDESS) sequence with automatic T2 mapping and deep learning super-resolutionaugmentation and to compare the diagnostic performance of the two methods regarding findings from arthroscopic surgery. METHODS. Fifty-one patients with knee pain underwent knee MRI that included an additional 3D qDESS sequence with automatic T2 mapping. Fourier interpolation was followed by prospective deep learning super resolution to enhance qDESS slice resolution twofold. A musculoskeletal radiologist and a radiology resident performed independent retrospective evaluations of articular cartilage, menisci, ligaments, bones, extensor mechanism, and synovium using conventional MRI. Following a 2-month washout period, readers reviewed qDESS images alone followed by qDESS with the automatic T2 maps. Interreader agreement between conventional MRI and qDESS was computed using percentage agreement and Cohen kappa. The sensitivity and specificity of conventional MRI, qDESS alone, and qDESS plus T2 mapping were compared with arthroscopic findings using exact McNemar tests. RESULTS. Conventional MRI and qDESS showed 92% agreement in evaluating all tissues. Kappa was 0.79 (95% CI, 0.76-0.81) across all imaging findings. In 43 patients who underwent arthroscopy, sensitivity and specificity were not significantly different (p = .23 to > .99) between conventional MRI (sensitivity, 58-93%; specificity, 27-87%) and qDESS alone (sensitivity, 54-90%; specificity, 23-91%) for cartilage, menisci, ligaments, and synovium. For grade 1 cartilage lesions, sensitivity and specificity were 33% and 56%, respectively, for conventional MRI; 23% and 53% for qDESS (p = .81); and 46% and 39% for qDESS with T2 mapping (p = .80). For grade 2A lesions, values were 27% and 53% for conventional MRI, 26% and 52% for qDESS (p = .02), and 58% and 40% for qDESS with T2 mapping (p < .001). CONCLUSION. The qDESS method prospectively augmented with deep learning showed strong interreader agreement with conventional knee MRI and near-equivalent diagnostic performance regarding arthroscopy. The ability of qDESS to automatically generate T2 maps increases sensitivity for cartilage abnormalities. CLINICAL IMPACT. Using prospective artificial intelligence to enhance qDESS image quality may facilitate an abbreviated knee MRI protocol while generating quantitative T2 maps.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Chaudhari AS, Grissom MJ, Fang Z, et al. Diagnostic Accuracy of Quantitative Multicontrast 5-Minute Knee MRI Using Prospective Artificial Intelligence Image Quality Enhancement. AJR Am J Roentgenol. 2020. PMID: 32755384. doi:10.2214/AJR.20.24172

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。