文献速递甲状腺与浅表US

剪切波弹性成像自由感兴趣区技术评估Graves病甲状腺实质硬度

Evaluation of the Stiffness of Thyroid Parenchyma With Shear Wave Elastography Using a Free-Region of Interest Technique in Graves Disease.
PubMed 文献 · J Ultrasound Med · 2020-08-07

前瞻性研究纳入50例Graves病患者与54名无症状志愿者,采用剪切波弹性成像自由感兴趣区技术测量甲状腺实质硬度。Graves病组弹性值显著高于对照组(17.34 kPa vs 12.05 kPa,P<.001),以14.5 kPa或2.115 m/s为 cutoff 值可高敏感度、高特异度诊断Graves病。

要点

  • Graves病甲状腺实质剪切波弹性值中位数17.34 kPa,显著高于对照组12.05 kPa(P<.001)。
  • 以14.5 kPa或2.115 m/s为 cutoff 值诊断Graves病具有高敏感度和高特异度。
  • Graves病组弹性值与实质回声强度呈弱负相关。

核心结论

  • 剪切波弹性成像可作为诊断Graves病的有效影像方法,具有高敏感度和高特异度。

研究设计与样本

  • 前瞻性研究,纳入50例临床和实验室检查提示Graves病的患者及54名实验室指标正常的无症状志愿者,采用剪切波弹性成像自由感兴趣区技术测量甲状腺实质硬度,并与灰阶超声及实验室参数进行相关性分析。

关键影像表现/征象

  • Graves病组甲状腺实质剪切波弹性值中位数(范围)为17.34(12.58-56.15)kPa,对照组为12.05(7.72-23.67)kPa,两组比较P<.001。
  • Graves病组剪切波速度中位数(范围)为2.28(1.83-4.12)m/s,对照组为1.92(1.55-2.61)m/s,两组比较P<.001。
  • Graves病组剪切波弹性值与甲状腺实质回声强度呈弱负相关。

诊断标准与关键数值

  • 以14.5 kPa为 cutoff 值时,剪切波弹性成像诊断Graves病具有高敏感度和高特异度。
  • 以2.115 m/s为 cutoff 值时,剪切波弹性成像诊断Graves病具有高敏感度和高特异度。

临床应用与阅片要点

  • 采用自由感兴趣区技术测量甲状腺实质剪切波弹性值,可作为Graves病诊断的辅助影像方法。
  • Graves病组弹性值与实质回声强度呈弱负相关,阅片时可结合灰阶超声表现综合判断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The first aim was to evaluate the stiffness of thyroid parenchyma with shear wave elastography (SWE) in patients with Graves disease (GD) and compare the elastographic values with those of asymptomatic volunteers. The second aim was to evaluate whether there was a correlation between SWE values and grayscale ultrasound (US) and laboratory parameters.

METHODS: In this prospective study, the thyroid gland parenchyma of 50 patients whose clinical and laboratory findings were indicative for GD and 54 asymptomatic participants with normal laboratory values was examined by SWE. Grayscale US images of the thyroid and submandibular gland were recorded. The volume of the thyroid gland was measured. Elastographic measurements were performed with a free region of interest. The quantitative SWE values (meters per second and kilopascals) of the patient and control groups were compared. A correlation analysis between the SWE values and grayscale US and laboratory parameters was performed.

RESULTS: The median (range) SWE values of the thyroid gland in patients with GD were significantly higher than those of the control group [17.34 (12.58-56.15) versus 12.05 (7.72-23.67) kPa and 2.28 (1.83-4.12) versus 1.92 (1.55-2.61) m/s; P < .001 for both comparisons]. When 14.5 kPa or 2.115 m/s was designated as the cutoff value, GD could be diagnosed with a high sensitivity and specificity. We showed a negative weak correlation between the SWE values and parenchymal echogenicity in the GD group.

CONCLUSIONS: Shear wave elastography can be used as an effective imaging method with high sensitivity and specificity rates in the diagnosis of GD.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Kılınçer A, Durmaz MS, Baldane S, et al. Evaluation of the Stiffness of Thyroid Parenchyma With Shear Wave Elastography Using a Free-Region of Interest Technique in Graves Disease. J Ultrasound Med. 2020. PMID: 32767605. doi:10.1002/jum.15422

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。