文献速递头颈CT

估算4D-CT上甲状旁腺重量、预测病理重量并诊断原发性甲状旁腺功能亢进症患者甲状旁腺腺瘤的简单公式

A Simple Formula to Estimate Parathyroid Weight on 4D-CT, Predict Pathologic Weight, and Diagnose Parathyroid Adenoma in Patients with Primary Hyperparathyroidism.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-08-13

单机构回顾性研究纳入116例原发性甲状旁腺功能亢进症患者,在术前4D-CT上用公式weight4D-CT=1 mg/mm3×长×宽×高×π/6估算甲状旁腺重量,并与病理标本重量相关性良好(Spearman ρ=0.73),诊断甲状旁腺腺瘤的AUC为0.955,最佳阈值>50 mg时敏感度96.7%、特异度95.7%。

要点

  • 4D-CT上按公式估算的甲状旁腺重量与病理重量强相关(ρ=0.73)。
  • 估算重量>50 mg鉴别腺瘤与正常腺体的敏感度96.7%、特异度95.7%。
  • 估算重量诊断甲状旁腺腺瘤的AUC为0.955(95%CI 0.925-0.985)。

核心结论

  • 放射科医生可在4D-CT上准确估算甲状旁腺腺瘤重量,该指标与病理重量高度相关,>50 mg阈值可用于区分甲状旁腺腺瘤与正常腺体。

研究设计与样本

  • 单机构回顾性研究,纳入2013年1月至2014年12月间接受4D-CT并随后行甲状旁腺切除术且手术治愈的原发性甲状旁腺功能亢进症患者116例(女85例、男31例),所有患者均正确定位单个甲状旁腺腺瘤。
  • 在CT上测量所有识别出的甲状旁腺的最长3个维度,用公式weight4D-CT(mg)=1 mg/mm3×长(mm)×宽(mm)×高(mm)×π/6估算重量,并与病理标本重量(weightpathology)做相关分析。
  • 采用受试者工作特征曲线分析评估weight4D-CT区分甲状旁腺腺瘤与正常腺体的效能,并基于约登指数确定最佳阈值。

诊断标准与关键数值

  • weight4D-CT与weightpathology强相关:Spearman ρ=0.73(P<.01)、一致性相关系数=0.92(95%CI 0.89-0.94)、Cronbach α=0.96。
  • weight4D-CT诊断甲状旁腺腺瘤的AUC为0.955(95%CI 0.925-0.985;P<.001)。
  • 基于约登指数的最佳阈值为>50 mg,敏感度96.7%、特异度95.7%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Parathyroid gland weight is a clinically relevant parameter used to diagnose parathyroid adenomas intraoperatively. We evaluated the accuracy of a formula to estimate parathyroid weight on preoperative 4D-CT.

MATERIALS AND METHODS: A single-institution retrospective study was performed in patients with primary hyperparathyroidism who underwent 4D-CT between January 2013 and December 2014 with subsequent parathyroidectomy and surgical cure. All patients had correct localization of a solitary parathyroid adenoma. The longest 3 dimensions of all identified parathyroid glands were measured on CT, and weight was estimated using the formula: weight4D-CT (mg) = 1 mg/mm3 × Length (mm) × Width (mm) × Height (mm) × π/6. We correlated weight4D-CT with pathology specimen weight (weightpathology). Using receiver operating characteristic analysis, we estimated the performance of weight4D-CT to discriminate a parathyroid adenoma from normal glands on 4D-CT and determined the optimal threshold based on the Youden index.

RESULTS: One hundred sixteen patients (85 women, 31 men) were evaluated. Weight4D-CT was shown to be strongly correlated with weightpathology as demonstrated by Spearman ρ = 0.73 (P < .01), concordance correlation coefficient = 0.92 (95% CI, 0.89-0.94), and Cronbach α = 0.96. The performance of weight4D-CT for the diagnosis of parathyroid adenoma was excellent, with an area under the curve of 0.955 (95% CI, 0.925-0.985; P < .001). Based on the Youden index, the optimal threshold was >50 mg, with a sensitivity of 96.7% and a specificity of 95.7%.

CONCLUSIONS: Radiologists can accurately estimate parathyroid adenoma weight on 4D-CT. This metric is highly correlated with pathologic weight, and a threshold cutoff of >50 mg can be used to distinguish parathyroid adenoma from normal glands.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Yeh R, Tay YD, Dercle L, et al. A Simple Formula to Estimate Parathyroid Weight on 4D-CT, Predict Pathologic Weight, and Diagnose Parathyroid Adenoma in Patients with Primary Hyperparathyroidism. AJNR Am J Neuroradiol. 2020. PMID: 32816774. doi:10.3174/ajnr.A6687

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。