TI-RADS分类系统与二代基因测序在不确定甲状腺结节中的诊断价值
回顾性分析2017年1月至2018年8月因甲状腺结节行超声并随后细针穿刺±手术切除的121例患者136个结节,以细胞学和二代基因测序作为恶性风险参考标准,评估ACR TI-RADS的诊断准确性及阅片者间和阅片者内可靠性。结果显示阅片者间可靠性为边缘(κ=0.293),阅片者内可靠性从边缘到良好(κ=0.337至0.560),ROC曲线下面积为0.509,不存在识别高风险结节的最佳TI-RADS级别。结论认为ACR TI-RADS在评估细胞学不确定结节的遗传风险时,阅片者间和阅片者内可靠性低。
要点
- ACR TI-RADS在评估细胞学不确定结节的遗传风险时,阅片者间可靠性为边缘(κ=0.293)。
- 阅片者内可靠性范围为边缘到良好(κ=0.337至0.560)。
- ROC曲线下面积为0.509,不存在识别高风险结节的最佳TI-RADS级别。
核心结论
- ACR TI-RADS分类系统在评估细胞学不确定结节的遗传风险时,表现出低的阅片者间和阅片者内可靠性。
研究设计与样本
- 回顾性病历审查,纳入2017年1月至2018年8月因甲状腺结节行超声并随后细针穿刺±手术切除的患者,共121例患者136个结节;由四位擅长甲状腺超声的放射科医生间隔至少1个月两次评估图像;以细胞学和二代基因测序结果作为恶性高风险与低风险的参考标准;采用单变量分析、kappa统计和受试者工作特征曲线。
诊断标准与关键数值
- 135个结节中118个(87%)为不确定细胞学(Bethesda III或IV);23种高风险突变中检出1种,见于30.1%(42个)结节;52例手术患者中24例(47.1%)经手术病理证实为恶性;阅片者间可靠性κ=0.293;阅片者内可靠性κ=0.337至κ=0.560;ROC曲线下面积0.509;未找到识别高风险结节的最佳TI-RADS级别。
临床应用与阅片要点
- 原文结论认为ACR TI-RADS在评估细胞学不确定结节的遗传风险时阅片者间和阅片者内可靠性低,未据此给出临床推荐。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aims to evaluate the diagnostic accuracy, inter-reader, and intra-reader variability of the ACR Thyroid Imaging Reporting and Data System (TI-RADS) for risk-stratification of indeterminate thyroid nodules using next generation genetic sequencing and tissue histology as a reference standard.
MATERIALS AND METHODS: Retrospective chart review was performed on all patients who underwent thyroid ultrasound for a nodule with subsequent fine-needle aspiration ± surgical resection from January 2017 to August 2018. Four radiologists with expertise in thyroid ultrasound assessed imaging twice, ≥1 month apart. Results of cytology and next generation genetic sequencing were used as a reference standard for high versus low risk of malignancy in each nodule. Inter-reader reliability between readers and intra-reader reliability between replicate self-reads for TI-RADS categorization were assessed. Univariate analysis, kappa statistics, and receiver operating characteristic curve were calculated.
RESULTS: One hundred and thirty six nodules across 121 patients met inclusion criteria. 84.6% of patients were female and average age was 55.8 ± 14.1 years. One hundred and eighteen of 135 nodules (87%) had indeterminate cytology (Bethesda III or IV). One of 23 high-risk mutations was identified in 30.1% (42) of the nodules. Of the 52 patients who had surgery, 24 (47.1%) had confirmed malignant disease on surgical pathology. Inter-reader reliability between the four radiologists was marginal, κ = 0.293. Intra-reader reliability ranged from marginal to good, κ = 0.337 to κ = 0.560, respectively. The area under the receiver operating characteristic curve was 0.509, and no optimal TI-RADS Level for identifying high-risk nodules existed.
CONCLUSION: The ACR TI-RADS classification system performs with low inter-reader and intra-reader reliability when assessing the genetic risk of nodules with indeterminate cytology.
引用
- Daniels KE, Xu J, Liu JB, et al. Diagnostic Value of TI-RADS Classification System and Next Generation Genetic Sequencing in Indeterminate Thyroid Nodules. Acad Radiol. 2020. PMID: 32839097. doi:10.1016/j.acra.2020.07.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。