文献速递甲状腺与浅表头颈US

甲状腺超声自动化结构化报告:对报告错误与效率的影响

Automated Structured Reporting for Thyroid Ultrasound: Effect on Reporting Errors and Efficiency.
PubMed 文献 · J Am Coll Radiol · 2020-08-18

这项回顾性研究由4名放射科医生使用ACR TI-RADS对甲状腺超声进行报告,比较自由文本、最低结构化、完全结构化及完全结构化并自动化四种模板,每种模板80份报告。自动化模板报告错误率为0%,低于其他模板,报告时间中位数180秒,医生主观上更偏好自动化模板。

要点

  • 自动化结构化模板报告错误率为0%,自由文本模板为27.5%。
  • 自动化模板中位报告时间为180秒,较简单模板的210至240秒无统计学显著差异(P = .41)。
  • 放射科医生主观上更偏好使用自动化模板。

诊断标准与关键数值

  • 错误定义为ACR TI-RADS相关的分值赋值、分值相加、风险等级判定和推荐意见错误。
  • 自由文本模板错误率为27.5%(80份中22份),最低结构化模板为28.8%(80份中23份),完全结构化模板为18.8%(80份中15份),完全结构化并自动化模板为0%(80份中0份),P < .0001。
  • 各类型错误(分值赋值、相加、TR分类、推荐意见)的频率在四种模板间递减,P < .0005至P < .005。
  • 较简单模板的中位报告时间为210至240秒,自动化模板的中位报告时间为180秒,P = .41。

临床应用与阅片要点

  • 作者结论认为,自动执行ACR TI-RADS步骤的结构化报告模板可使放射科医生的报告错误减少。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the effectiveness of different reporting templates using the ACR Thyroid Imaging Reporting and Data System (TI-RADS) for thyroid ultrasound.

METHODS: In this retrospective study, four radiologists implemented ACR TI-RADS while dictating 20 thyroid ultrasounds for each of four different templates: free text, minimally structured, fully structured, fully structured and automated (embedded software automatically sums TI-RADS points, correlates with nodule size, and inserts appropriate recommendation into report impression). In total, 80 reports were constructed per template type. Frequencies of different errors related to ACR TI-RADS were recorded: errors in point assignment, point addition, risk-level assignment, and recommendation. Reporting times were recorded, and a survey about using the template was administered. Differences in error rates were compared using χ2 and Fisher's exact tests, and differences in reporting times were compared using Kruskal-Wallis tests.

RESULTS: Across all readers, errors were identified in 27.5% of reports (22 of 80) for the free text template, 28.8% (23 of 80) for the minimally structured template, 18.8% (15 of 80) for the fully structured template, and 0% (0 of 80) for the fully structured and automated template (P < .0001). Frequency of each error type (number assignment, addition, TR categorization, recommendation) decreased across the four templates (P < .0005 to P < .005). Median reporting times for the less complex templates were 210 to 240 seconds, whereas the median automated template reporting time was 180 seconds (P = .41). Radiologists subjectively preferred using the automated template.

CONCLUSION: A structured reporting template for thyroid ultrasound that automatically executed steps of ACR TI-RADS resulted in fewer reporting errors for radiologists.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Wildman-Tobriner B, Ngo L, Jaffe TA, et al. Automated Structured Reporting for Thyroid Ultrasound: Effect on Reporting Errors and Efficiency. J Am Coll Radiol. 2020. PMID: 32818484. doi:10.1016/j.jacr.2020.07.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。