文献速递乳腺MR

浸润性乳腺癌动态增强MRI强化动力学异质性及其对远处转移的提示意义

Heterogeneity of enhancement kinetics in dynamic contrast-enhanced MRI and implication of distant metastasis in invasive breast cancer.
PubMed 文献 · Clin Radiol · 2020-08-25

本研究对128例浸润性乳腺癌患者行基于像素的动态增强MRI时间-信号强度曲线(TIC)分析,计算各肿瘤中持续型、平台型、廓清型及无强化型TIC的百分比。持续型TIC百分比>22.5%和无强化型TIC百分比>2.5%与远处转移相关;联合TIC模式、肿瘤大小和腋窝淋巴结状态的多变量模型在留一交叉验证中AUC为0.87,敏感度0.70、特异度0.87。作者认为基于像素的TIC分析有助于预测浸润性乳腺癌的远处转移。

要点

  • 持续型TIC百分比>22.5%和无强化型TIC百分比>2.5%与浸润性乳腺癌远处转移相关。
  • TIC模式联合肿瘤大小和腋窝淋巴结状态的多变量模型在留一交叉验证中AUC为0.87。
  • 基于像素的TIC分析可半自动分类瘤内不同强化模式并计算各模式百分比。

核心结论

  • 浸润性乳腺癌瘤内强化动力学异质性越高(持续型和无强化型TIC百分比较大)越可能发生远处转移。
  • 基于像素的TIC分析对预测浸润性乳腺癌远处转移有实用价值。
  • TIC模式联合肿瘤大小和腋窝淋巴结状态可提高预测效能。

研究设计与样本

  • 研究纳入128例浸润性乳腺癌患者,采用基于像素的动态增强MRI分析瘤内时间-信号强度曲线(TIC)模式。
  • 该MRI技术可半自动分类持续型、平台型、廓清型和无强化型TIC像素,并计算各模式在肿瘤中的百分比。
  • 比较远处转移组与非远处转移组之间TIC模式百分比的差异,并用Kaplan-Meier生存分析估计无远处转移生存。
  • 多变量模型采用留一交叉验证(LOOCV)评价预测效能。

关键影像表现/征象

  • 持续型TIC百分比较大与浸润性乳腺癌远处转移相关,其界值为22.5%。
  • 无强化型TIC百分比较大与浸润性乳腺癌远处转移相关,其界值为2.5%。
  • Kaplan-Meier分析显示这些预测因素在无远处转移生存上差异有统计学意义。

诊断标准与关键数值

  • 持续型TIC百分比界值为22.5%,用于区分远处转移与非远处转移。
  • 无强化型TIC百分比界值为2.5%,用于区分远处转移与非远处转移。
  • 联合TIC模式、肿瘤大小和腋窝淋巴结状态的多变量模型在留一交叉验证中AUC为0.87,敏感度0.70,特异度0.87。

临床应用与阅片要点

  • 阅片时可对浸润性乳腺癌行基于像素的TIC分析,量化持续型和无强化型TIC百分比以评估瘤内强化异质性。
  • 持续型TIC百分比>22.5%或无强化型TIC百分比>2.5%时提示远处转移风险较高。
  • 可将TIC模式分析与肿瘤大小、腋窝淋巴结状态联合用于远处转移风险预测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the heterogeneity of enhancement kinetics for breast tumour in order to demonstrate the predictive power of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) features for distant metastasis (DM) in invasive breast cancer.

MATERIALS AND METHODS: Time-signal intensity curve (TIC) patterns from 128 patients with invasive breast cancer were analysed by a pixel-based DCE-MRI analysis. This MRI technique enabled pixels with varying TIC patterns (persistent, plateau, washout and non-enhancement) to be categorised semi-automatically and the percentage of different TIC patterns in each breast tumour to be calculated. The percentage of TIC patterns was compared between the DM and non-DM groups. DM-free survival was estimated using Kaplan-Meier survival analysis.

RESULTS: This study demonstrated a larger percentage of persistent TIC and non-enhancement TIC was associated with DM in invasive breast cancer. The cut-off values of persistent TIC and non-enhancement TIC were 22.5% and 2.5%. Combining TIC patterns and traditional predictors (tumour size and axillary lymph node status) can improve the prediction efficiency. The multivariable model yielded an area under the receiver operating characteristic curve (AUC) of 0.87 with 0.70 sensitivity and 0.87 specificity in leave-one-out cross-validation (LOOCV). These predictors showed significant differences in DM-free survival by Kaplan-Meier analysis.

CONCLUSION: This study shows that breast tumours with higher heterogeneity are more likely to metastasise, and pixel-based TIC analysis has utility in predicting distant metastasis of invasive breast cancer.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Zhao R, Ma WJ, Tang J, et al. Heterogeneity of enhancement kinetics in dynamic contrast-enhanced MRI and implication of distant metastasis in invasive breast cancer. Clin Radiol. 2020. PMID: 32859381. doi:10.1016/j.crad.2020.07.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。