文献速递乳腺US

超微血管成像血管指数在乳腺肿块评估中的附加价值:与灰阶超声的比较

Added Value of the Vascular Index on Superb Microvascular Imaging for the Evaluation of Breast Masses: Comparison With Grayscale Ultrasound.
PubMed 文献 · J Ultrasound Med · 2020-08-20

本研究对70例连续患者的70个乳腺肿块(36个恶性、34个良性)行灰阶超声与超微血管成像(SMI)检查,由2名乳腺影像医师分别分析单纯灰阶超声及灰阶超声联合SMI,并基于SMI测量血管指数(VI);恶性肿块VI显著高于良性(P<.001),鉴别良恶性的最佳阈值为2.95,敏感度86.1%、特异度91.2%,作者认为灰阶超声联合SMI及VI可能改善乳腺肿块的定性。

要点

  • 恶性乳腺肿块VI显著高于良性(P<.001),最佳阈值2.95时敏感度86.1%、特异度91.2%。
  • 灰阶超声联合SMI的AUC:医师1为0.912 vs 单纯灰阶0.824(P=.028),医师2为0.853 vs 0.795(P=.101)。
  • 影像分析与VI的观察者间一致性几乎完美。

核心结论

  • 恶性乳腺肿块的SMI血管指数显著高于良性病变,观察者间一致性高。
  • 作者认为灰阶超声联合SMI及VI可能改善乳腺肿块的定性。

研究设计与样本

  • 单中心前瞻性设计未在原文说明;本文为诊断准确性研究,纳入70例连续患者的70个乳腺肿块(36个恶性、34个良性)。
  • 采用灰阶超声与SMI(Canon Medical Systems Corporation,东京,日本)检查,由2名乳腺影像医师分析单纯灰阶超声及灰阶超声联合SMI,并基于SMI测量VI;以病理为参考标准。

关键影像表现/征象

  • 原文未描述具体灰阶超声征象或SMI血流形态学表现。

诊断标准与关键数值

  • VI鉴别恶性与良性乳腺肿块的最佳阈值为2.95,敏感度86.1%、特异度91.2%。
  • 单纯灰阶超声与灰阶超声联合SMI的诊断性能值:医师1为0.824 vs 0.912(P=.028);医师2为0.795 vs 0.853(P=.101)。
  • 恶性肿块VI显著高于良性(P<.001);影像分析及VI的观察者间一致性几乎完美。

临床应用与阅片要点

  • 作者认为灰阶超声联合SMI测量VI可能改善乳腺肿块定性,阅片时可结合VI阈值2.95辅助判断良恶性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the value of the vascular index (VI) on Superb Microvascular Imaging (SMI; Canon Medical Systems Corporation, Tokyo, Japan) in comparison with grayscale ultrasound (US) alone for assessing breast masses.

METHODS: We evaluated a total of 70 breast masses (36 malignant and 34 benign lesions) in 70 consecutive patients using grayscale US and SMI. Two breast radiologists analyzed grayscale US alone and the combination of grayscale US and SMI. They also measured the VI based on SMI. The diagnostic performance of grayscale US alone and the combination of grayscale US and SMI was compared. The VI was compared between benign and malignant masses, and the optimal cutoff value was determined. In addition, the interobserver agreement in imaging analyses and the VI was assessed.

RESULTS: The interobserver agreements in imaging analyses and the VI were almost perfect. The VI of malignant breast masses was significantly higher than that of benign lesions (P < .001). The optimal cutoff value of the VI for differentiating between malignant and benign breast masses was 2.95, with sensitivity of 86.1% and specificity of 91.2%. The diagnostic performance values of grayscale US alone and the combination of grayscale US and SMI were 0.824 and 0.912, respectively, for reader 1 (P = .028) and 0.795 and 0.853 for reader 2 (P = .101).

CONCLUSIONS: The VI on SMI was significantly higher for malignant breast masses than for benign lesions, with high interobserver agreement. Our study suggests that the combination of grayscale US and SMI with the VI could improve the characterization of breast masses.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Chae EY, Yoon GY, Cha JH, et al. Added Value of the Vascular Index on Superb Microvascular Imaging for the Evaluation of Breast Masses: Comparison With Grayscale Ultrasound. J Ultrasound Med. 2020. PMID: 32815564. doi:10.1002/jum.15441

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。