文献速递乳腺US乳腺X线

超声造影在诊断伴钙化的乳腺超声BI-RADS 3和4类病变中的价值

Value of contrast-enhanced ultrasound in the diagnosis of breast US-BI-RADS 3 and 4 lesions with calcifications.
PubMed 文献 · Clin Radiol · 2020-08-16

回顾性分析152例患者168个在乳腺X线和常规超声上均可见钙化、超声分类为US-BI-RADS 3-4类的乳腺病变,基于CEUS五点评分系统构建CEUS-BI-RADS并与组织学对照。CEUS-BI-RADS较常规超声显著提高诊断敏感度(98.2% vs 81.8%,p=0.003)和准确率(92.9% vs 83.9%,p=0.004),AUC为0.963 vs 0.888(p=0.004)。

要点

  • 对伴钙化的US-BI-RADS 3-4类病变,CEUS-BI-RADS的AUC为0.963,高于常规超声的0.888(p=0.004)。
  • CEUS-BI-RADS敏感度98.2%、特异度90.3%、准确率92.9%,常规超声分别为81.8%、85%、83.9%。
  • CEUS五点评分与US-BI-RADS联合形成CEUS-BI-RADS,可提升伴钙化乳腺病变的诊断效能。

诊断标准与关键数值

  • 常规超声诊断敏感度81.8%(95%CI:71.6%,92%)、特异度85%(95%CI:78.4%,91.5%)、准确率83.9%(95%CI:78.4%,89.5%)。
  • CEUS-BI-RADS诊断敏感度98.2%(95%CI:94.7%,100%)、特异度90.3%(95%CI:84.8%,95.7%)、准确率92.9%(95%CI:89%,96.8%)。
  • 常规超声与CEUS-BI-RADS的ROC曲线下面积分别为0.888(95%CI:0.840,0.936)和0.963(95%CI:0.936,0.989)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the diagnostic performance of contrast-enhanced ultrasound (CEUS) for Breast Imaging-Reporting and Data System for Ultrasound (US-BI-RADS) 3 and 4 lesions with calcifications.

MATERIALS AND METHODS: A retrospective study of 168 breast lesions with calcifications detected on both mammography and conventional ultrasonography (US) in 152 patients were categorised as US-BI-RADS 3-4 at US between June 2009 and June 2018. CEUS scores were obtained based on a CEUS five-point scoring system. The combination of US-BI-RADS and CEUS scores created the Rerated BI-RADS (referred to as CEUS-BI-RADS). All results were compared with the histological findings. The diagnostic performances of US and CEUS-BI-RADS were compared.

RESULTS: The diagnostic sensitivity, specificity, and accuracy of US were 81.8% (95% confidence interval [CI]: 71.6%, 92%), 85% (95% CI: 78.4%, 91.5%), and 83.9% (95% CI: 78.4%, 89.5%), respectively, while those for CEUS-BI-RADS were 98.2% (95% CI: 94.7%, 100%), 90.3% (95% CI: 84.8%, 95.7%), and 92.9% (95% CI: 89%, 96.8%), respectively. The diagnostic sensitivity and accuracy values of CEUS-BI-RADS greatly improved compared with those of US (p=0.003 and p=0.004, respectively). The areas under the receiver operating characteristic (ROC) curves for US and CEUS-BI-RADS were 0.888 (95% CI: 0.840, 0.936) and 0.963 (95% CI: 0.936, 0.989), respectively. The diagnostic efficacy of CEUS-BI-RADS was significantly higher than that of US alone (p=0.004).

CONCLUSION: CEUS-BI-RADS significantly improves the diagnostic accuracy for breast US-BI-RADS 3 and 4 lesions with calcifications compared with US.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Cheng M, Tong W, Luo J, et al. Value of contrast-enhanced ultrasound in the diagnosis of breast US-BI-RADS 3 and 4 lesions with calcifications. Clin Radiol. 2020. PMID: 32814625. doi:10.1016/j.crad.2020.07.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。