文献速递乳腺US乳腺X线

自动乳腺超声与手持超声及乳腺X线摄影在有症状门诊女性中的诊断效能:中国多中心横断面研究

The diagnostic performance of automated versus handheld breast ultrasound and mammography in symptomatic outpatient women: a multicenter, cross-sectional study in China.
PubMed 文献 · Eur Radiol · 2020-08-27

该多中心横断面研究于2016年2月至2017年3月在中国五家三级医院纳入1922名30-69岁有症状女性,比较自动乳腺超声(ABUS)、手持超声(HHUS)和乳腺X线摄影(MG)的诊断效能。全人群ABUS与HHUS敏感度分别为92.8%和96.3%,特异度分别为93.0%和89.6%;B组中ABUS较MG敏感度更高(93.5% vs 87.9%,p=0.02),特异度相当(93.0% vs 91.6%,p=0.14)。结论认为ABUS在乳腺癌诊断中较MG敏感度更高、特异度相似,与HHUS效能相当,适合作为乳腺癌诊断的检查方式。

要点

  • 全人群ABUS特异度93.0%高于HHUS的89.6%(p<0.01),但敏感度92.8%低于HHUS的96.3%(p=0.01)。
  • 40-69岁组ABUS敏感度93.5%高于MG的87.9%(p=0.02),特异度93.0%与MG的91.6%相当(p=0.14)。
  • ABUS与HHUS在30-69岁女性中诊断效能相当,ABUS或HHUS均适合乳腺癌诊断。

核心结论

  • ABUS较乳腺X线摄影提高了敏感度且特异度相似;ABUS与HHUS在30-69岁女性中效能相当;ABUS或HHUS是适合乳腺癌诊断的检查方式。

研究设计与样本

  • 多中心横断面研究,2016年2月至2017年3月在中国五家三级医院纳入1922名30-69岁有症状门诊女性;30-39岁组(A组)行ABUS和HHUS,40-69岁组(B组)加行MG;采用BI-RADS分类判读,所有BI-RADS 4和5类病例经病理证实。

诊断标准与关键数值

  • 全人群ABUS敏感度92.8%(375/404)、特异度93.0%(1411/1518);HHUS敏感度96.3%(389/404)、特异度89.6%(1360/1518)。B组ABUS敏感度93.5%(300/321)、特异度93.0%(859/924);HHUS敏感度96.6%(310/321)、特异度89.9%(831/924);MG敏感度87.9%(282/321)、特异度91.6%(846/924)。

临床应用与阅片要点

  • ABUS或HHUS可作为有症状女性乳腺癌诊断的适宜检查方式,ABUS可能具有用于乳腺癌早期检测的潜在适应症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to evaluate the diagnostic performance of automated breast ultrasound (ABUS) for breast cancer by comparing it to handheld ultrasound (HHUS) and mammography (MG).

METHODS: A multicenter cross-sectional study was conducted between February 2016 and March 2017 in five tertiary hospitals in China, and 1922 women aged 30-69 years old were recruited. Women aged 30-39 years (group A) underwent ABUS and HHUS, and women aged 40-69 (group B) underwent additional MG. Images were interpreted using the Breast Imaging Reporting and Data System (BI-RADS). All BI-RADS 4 and 5 cases were confirmed pathologically. Sensitivities and specificities of all modalities were compared.

RESULTS: There were 83 cancers in 677 women in group A and 321 cancers in 1245 women in group B. In the whole study population, the sensitivities of ABUS and HHUS were 92.8% (375/404) and 96.3% (389/404), and the specificities were 93.0% (1411/1518) and 89.6% (1360/1518), respectively. ABUS had a significantly higher specificity to HHUS (p < 0.01), while HHUS had higher sensitivity (p = 0.01). In group B, the sensitivities of ABUS, HHUS, and MG were 93.5% (300/321), 96.6% (310/321), and 87.9% (282/321). The specificities were 93.0% (859/924), 89.9% (831/924), and 91.6% (846/924). ABUS had significantly higher sensitivity (p = 0.02) and comparable specificity compared with MG (p = 0.14).

CONCLUSION: ABUS increased sensitivity and had similar specificity compared with mammography in the diagnosis of breast cancer. Additionally, ABUS has comparable performance to HHUS in women aged 30-69 years old. ABUS or HHUS is a suitable modality for breast cancer diagnosis.

KEY POINTS: • In breast cancer diagnosis settings, automated breast ultrasound has a higher cancer detection rate, sensitivity, and specificity than mammography, especially in women with dense breasts. • Compared with handheld ultrasound, automated breast ultrasound has higher specificity, lower sensitivity, and comparable diagnostic performance. • Automated breast ultrasound is a suitable modality for breast cancer diagnosis, and may have a potential indication for its further use in the breast cancer early detection.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lin X, Jia M, Zhou X, et al. The diagnostic performance of automated versus handheld breast ultrasound and mammography in symptomatic outpatient women: a multicenter, cross-sectional study in China. Eur Radiol. 2020. PMID: 32852589. doi:10.1007/s00330-020-07197-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。