在断层合成筛查中发现非钙化乳腺病灶后检查中成像方法的选择
该回顾性研究比较了诊断性乳腺X线摄影、诊断性乳腺X线摄影联合超声以及单独超声在评估数字乳腺断层合成(DBT)筛查召回的非钙化病灶中的应用。结果显示,肿块更倾向于单独使用超声评估,且更可能为真性病灶;不对称和局灶性不对称更倾向于使用诊断性乳腺X线摄影联合超声或单独诊断性乳腺X线摄影评估;召回病灶类型间恶性与良性活检结果无显著差异。
要点
- DBT筛查召回的肿块更常仅用超声评估,且真性病灶比例高(90%)。
- 结构扭曲在诊断评估中更常被归为BI-RADS 4或5类。
- 召回病灶类型间恶性与良性活检结果无显著差异(p=0.71)。
关键影像表现/征象
- 肿块比其他召回病灶类型更常仅用超声评估(OR=7.63;95%CI [4.17-13.97];p<0.01)。
- 结构扭曲比其他病灶类型在诊断评估中更常被归为BI-RADS 4或5类(OR=7.71;95%CI [2.82-21.04];p<0.01)。
- 肿块为真性病灶的比例为90%(111/124),高于局灶性不对称的40%(23/57)(OR=11.41;95%CI [4.05-32.14];p<0.01)和不对称的24%(16/67)(OR=27.01;95%CI [9.41-77.48];p<0.01)。
诊断标准与关键数值
- 召回的非钙化病灶类型包括结构扭曲、不对称、局灶性不对称和肿块。
- 诊断评估采用BI-RADS分类,结构扭曲更常被归为BI-RADS 4或5类(OR=7.71;95%CI [2.82-21.04];p<0.01)。
- 真性病灶比例:肿块90%(111/124)、局灶性不对称40%(23/57)、不对称24%(16/67)。
- 召回DBT病灶类型间恶性与良性活检结果无显著差异(p=0.71)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this study is to compare the use of diagnostic mammography, diagnostic mammography with ultrasound, and ultrasound alone in the evaluation of recalled non-calcified lesions from screening mammography with digital breast tomosynthesis (DBT).
METHODS: We performed a retrospective review of recalled non-calcified lesions that included architectural distortion, asymmetry, focal asymmetry and mass from screening DBT from January 2014 to December 2016. Electronic health records were reviewed for imaging evaluations, findings and histopathology results.
RESULTS: Of 266 non-calcified lesions in 247 women, masses were significantly more likely to be evaluated with ultrasound alone compared to diagnostic mammography with ultrasound than all other recalled finding types (OR = 7.63; 95 %CI [4.17-13.97]; p < 0.01). Architectural distortions were more likely to be assigned a BI-RADS 4 or 5 on the diagnostic evaluation than all other lesion types (OR = 7.71; 95 %CI [2.82-21.04]; p < 0.01). Masses were more likely to be true lesions (90 %; 111/124) compared to 40 % (23/57) of focal asymmetries (OR = 11.41; 95 %CI [4.05-32.14]; p < 0.01) and 24 % (16/67) of asymmetries (OR = 27.01; 95 %CI [9.41-77.48]; p < 0.01). No significant difference was noted in the malignant versus benign biopsy outcomes among the recalled DBT lesion types (p = 0.71).
CONCLUSION: Recalled masses from screening DBT were more likely to be worked up with ultrasound alone compared to all other non-calcified lesion types and more likely to represent true lesions on diagnostic evaluation. Recalled asymmetries and focal asymmetries were more likely to be worked up with either diagnostic mammography with ultrasound or diagnostic mammography alone.
引用
- Porembka JH, Baydoun S, Mootz AR, et al. Choice of imaging method in the work-up of non-calcified breast lesions identified on tomosynthesis screening. Eur J Radiol. 2020. PMID: 32771916. doi:10.1016/j.ejrad.2020.109203
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。