影像组学对乳腺超声放射科医生临床实践的影响:从肿块辨识者到数据整理者
研究连续分析2018年1月至2019年4月因经皮乳腺活检转诊的207个超声肿块,用专用超声软件(AI)以0-100分自动分类并采用组织学为金标准,确定影像组学恶性截断点及±10%边界误差范围定义为不确定肿块。143个良性、64个恶性;最佳分类准确度为阅片者联合AI(0.829)。结论认为AI对乳腺超声肿块分类性能可靠,放射科医生验证对最终BI-RADS评估至关重要,尤其对不确定肿块。
要点
- AI软件以0-100分自动分类乳腺超声肿块,100分为最可疑,组织学为金标准。
- 按约登指数确定恶性截断点并设±10%边界误差,该范围内肿块视为不确定肿块。
- 阅片者联合AI的分类准确度最高(0.829),优于单独AI或单独阅片者。
核心结论
- 人工智能在乳腺超声肿块分类中性能可靠,放射科医生验证对最终BI-RADS评估至关重要,尤其对不确定肿块方能获得最佳分类性能。
研究设计与样本
- 连续分析2018年1月至2019年4月因经皮乳腺活检转诊的207个超声肿块,采用专用超声软件(AI)自动分类并以组织学结果为金标准。
关键影像表现/征象
- AI最常见的不确定良性肿块为纤维腺瘤,其次为叶状肿瘤、脂肪坏死;不确定恶性病变为低级别和高别浸润性导管癌。
诊断标准与关键数值
- AI软件自动将肿块按0-100分分类,100分为最可疑。
- 按约登指数确定影像组学恶性截断点,并设±10%边界误差范围,该范围内肿块视为不确定肿块。
- 约登指数为0.516,不确定肿块范围±10%(0.464-0.567)。
- 207个肿块中143个良性、64个恶性;不确定范围内良性21个(14.58%)、恶性12个(19.05%)。
- 分类准确度最佳为阅片者联合AI(0.829)。
临床应用与阅片要点
- 放射科医生对AI结果的验证是确定最终BI-RADS评估的关键,尤其对不确定肿块。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The study aims to assess the impact of radiomics in the clinical practice of breast ultrasound, to determine which lesions are undetermined by the software, and to discuss the future of the radiologist's role.
METHODS: Consecutive analyses of 207 ultrasound masses from January 2018 to April 2019 referred for percutaneous breast biopsy. Breast masses were classified using dedicated ultrasound software (AI). The AI software automatically classified the masses on a scale of 0-100, where 100 is the most suspicious. We adopt the histology results as the gold standard. The cut-off point of malignancy by radiomics was determined, with ±10 % of margin error according to the Youden's index. We considered these lesions as undetermined masses. The performance of the AI software and the radiologist classification was compared using the area under roc curves (AUROC). We also discuss the impact of radiologist validation of AI results, especially in undetermined lesions.
RESULTS: Of the 207 evaluated masses, 143 were benign, and 64 were malignant. The Youden's index was 0.516, including undetermined masses with a varied range of 10 % (0.464-0.567). Twenty-one (14.58 %) benign and twelve (19.05 %) malignant masses were in this range. The best accuracy performance to classify masses was the combination of the reader and AI (0.829). The most common undetermined masses in AI were fibroadenoma, followed by phyllodes tumor, steatonecrosis as benign. Whereas, low-grade, and high-grade invasive ductal carcinoma represents the malignant lesions.
CONCLUSIONS: Artificial Intelligence has a reliable performance in ultrasound breast masses classification. Radiologist validation is critical to determine the final BI-RADS assessment, especially in undetermined masses to obtain the best classification performance.
引用
- Fleury EFC, Marcomini K. Impact of radiomics on the breast ultrasound radiologist's clinical practice: From lumpologist to data wrangler. Eur J Radiol. 2020. PMID: 32795725. doi:10.1016/j.ejrad.2020.109197
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。