第五版BI-RADS超声词典在乳腺4类病变中的应用:中国前瞻性多中心研究
该研究前瞻性纳入32家三级医院的2049例BI-RADS 4类乳腺肿块女性患者,按第五版BI-RADS超声词典描述并分类,以病理为参考标准计算4a-4c的阳性预测值。结果示4a、4b、4c恶性率分别为7.4%、61.4%、93.0%,4b的PPV高于BI-RADS规定范围,4a和4c在可接受范围内。
要点
- 4a、4b、4c恶性率分别为7.4%(72/975)、61.4%(283/461)、93.0%(570/613)。
- 毛刺边缘PPV 83.7%、结构扭曲PPV 89.3%、皮肤改变PPV 76.2%,为高预测价值征象。
- 4b的PPV高于BI-RADS规定范围,4a和4c在可接受范围内。
关键影像表现/征象
- 肿块形状、方向、边缘、后方特征、钙化、结构扭曲、水肿、皮肤改变、血流和弹性评估在良恶性肿块间差异有统计学意义(p<0.05)。
- 恶性典型征象包括不规则形状(PPV 57.2%)、毛刺边缘(PPV 83.7%)、非平行方向(PPV 63.9%)和后方特征组合模式(PPV 60.6%)。
- 导管内钙化PPV 80%、内部血流PPV 56.4%、弹性成像硬模式PPV 80%。
- 伴随特征中结构扭曲PPV 89.3%、水肿PPV 69.2%、皮肤改变PPV 76.2%,对恶性显示高预测价值。
诊断标准与关键数值
- 4a类恶性率7.4%(72/975),4b类61.4%(283/461),4c类93.0%(570/613)。
- 4b的PPV高于BI-RADS规定范围,4a和4c的PPV在第五版BI-RADS可接受性能范围内。
临床应用与阅片要点
- 阅片时应同时描述肿块特征和伴随特征(结构扭曲、水肿、皮肤改变),并纳入血流和弹性评估。
- 毛刺边缘、结构扭曲、皮肤改变等高PPV征象对恶性提示价值较高。
- 4b类实际恶性率高于BI-RADS规定范围,报告分类时需结合本研究数据理解其风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The objective of this study was to evaluate the utility of the fifth edition of the Breast Imaging-Reporting and Data System (BI-RADS) in clinical breast radiology by using prospective multicenter real-time analyses of ultrasound (US) images.
MATERIALS AND METHODS: We prospectively studied 2049 female patients (age range, 19-86 years; mean age 46.88 years) with BI-RADS category 4 breast masses in 32 tertiary hospitals. All the patients underwent B-mode, color Doppler US, and US elastography examination. US features of the mass and associated features were described and categorized according to the fifth edition of the BI-RADS US lexicon. The pathological results were used as the reference standard. The positive predictive values (PPVs) of subcategories 4a-4c were calculated.
RESULTS: A total of 2094 masses were obtained, including 1124 benign masses (54.9%) and 925 malignant masses (45.1%). For BI-RADS US features of mass shape, orientation, margin, posterior features, calcifications, architectural distortion, edema, skin changes, vascularity, and elasticity assessment were significantly different for benign and malignant masses (p< 0.05). Typical signs of malignancy were irregular shape (PPV, 57.2%), spiculated margin (PPV, 83.7%), nonparallel orientation (PPV, 63.9%), and combined pattern of posterior features (PPV, 60.6%). For the changed or newly added US features, the PPVs for intraductal calcifications were 80%, 56.4% for internal vascularity, and 80% for a hard pattern on elastography. The associated features such as architectural distortion (PPV, 89.3%), edema (PPV, 69.2%), and skin changes (PPV, 76.2%) displayed high predictive value for malignancy. The rate of malignant was 7.4% (72/975) in category 4a, 61.4% (283/461) in category 4b, and 93.0% (570/613) in category 4c. The PPV for category 4b was higher than the likelihood ranges specified in BI-RADS and the PPVs for categories 4a and 4c were within the acceptable performance ranges specified in the fifth edition of BI-RADS in our study.
CONCLUSION: Not only the US features of the breast mass, but also associated features, including vascularity and elasticity assessment, have become an indispensable part of the fifth edition of BI-RADS US lexicon to distinguish benign and malignant breast lesions. The subdivision of category 4 lesions into categories 4a, 4b, and 4c for US findings is helpful for further assessment of the likelihood of malignancy of breast lesions.
引用
- Gu Y, Tian JW, Ran HT, et al. The Utility of the Fifth Edition of the BI-RADS Ultrasound Lexicon in Category 4 Breast Lesions: A Prospective Multicenter Study in China. Acad Radiol. 2020. PMID: 32768352. doi:10.1016/j.acra.2020.06.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。