俯卧位与立位数字断层合成引导活检的比较
本回顾性研究比较了俯卧位与立位数字乳腺断层合成(DBT)引导活检的性能,纳入2018年5月1日至2019年7月31日连续282例患者(俯卧位215例,立位67例)。所有活检技术成功,立位活检的平均曝光次数显著低于俯卧位(p < 0.001),其余指标(取样数、操作时间、钙化去除百分比、活检并发症)两组间无显著差异。
要点
- 立位DBT引导活检的平均曝光次数显著低于俯卧位(p < 0.001)。
- 两组在平均取样数、操作时间、钙化去除百分比及活检并发症上无显著差异。
- 选择俯卧位或立位DBT引导活检时,还应考虑房间利用率和患者舒适度等因素。
核心结论
- 除平均曝光次数外,俯卧位与立位DBT引导活检的临床性能相似。
- 选择俯卧位或立位DBT引导活检时,应考虑房间利用率和患者舒适度等其他因素。
研究设计与样本
- 回顾性研究,纳入2018年5月1日至2019年7月31日在本机构连续进行的全部DBT引导乳腺活检。
- 共282例患者:俯卧位DBT引导活检215例(76.2%),立位DBT引导活检67例(23.8%)。
- 记录患者年龄、乳腺密度、活检指征和技术、取样数、曝光次数、操作时间、钙化去除百分比、活检并发症、组织病理学诊断及影像-病理一致性。
- 采用卡方检验或Wilcoxon秩和检验比较两种活检方法。
诊断标准与关键数值
- 所有患者(100%)活检技术成功。
- 立位活检的平均曝光次数显著低于俯卧位(p < 0.001)。
- 平均取样数(p = 0.26)、平均操作时间(p = 0.67)、钙化去除百分比(p = 0.31)及活检并发症(p = 0.56)两组间无显著差异。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The objective of our study was to compare the performance of digital breast tomosynthesis (DBT)-guided prone and upright breast biopsies. MATERIALS AND METHODS. In this retrospective study, we reviewed all consecutive DBT-guided breast biopsies performed at our institution from May 1, 2018, to July 31, 2019. We recorded patient age, breast density, biopsy indications and technique, number of samples obtained, number of exposures performed, procedure times, percentage of calcifications removed, biopsy complications, histopathologic diagnosis, and radiology-pathology concordance. These characteristics were then compared between biopsy methods using the chi-square test or Wilcoxon rank sum test. RESULTS. There were 282 patients in our study: 215 patients (76.2%) underwent prone DBT-guided biopsy, and 67 (23.8%) underwent upright DBT-guided biopsy. All patients (100%) had technically successfully biopsies. The mean number of exposures for upright biopsies was significantly lower than the mean number of exposures for prone biopsies (p < 0.001). Otherwise, there was no significant difference between the two biopsy methods in the mean number of samples acquired (p = 0.26), mean procedure time (p = 0.67), percentage of calcifications removed (p = 0.31), or biopsy complications (p = 0.56). CONCLUSION. Besides the mean number of exposures acquired, prone and upright DBT-guided biopsies have similar clinical performance. Other factors, such as room utilization and patient comfort, should be considered when deciding between prone and upright DBT-guided biopsies.
引用
- Choudhery S, Johnson M, Fazzio RT, et al. Prone Versus Upright Digital Tomosynthesis-Guided Biopsy. AJR Am J Roentgenol. 2020. PMID: 32755154. doi:10.2214/AJR.19.22735
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。