批阅与间断判读数字筛查乳腺X线摄影(含与不含断层合成)的比较
回顾性比较2015年1月至2017年6月间批阅与间断判读的数字筛查乳腺X线摄影(含与不含断层合成)的表现指标。不含断层合成者批阅9832例、间断判读49496例,含断层合成者批阅7075例、间断判读24380例;两种模式下批阅的召回率均低于间断判读(P < .001),其余指标无显著差异。
要点
- 批阅较间断判读降低召回率:不含断层合成9.98% vs 11.3%,含断层合成6.98% vs 8.30%(均P < .001)。
- 两种模式下批阅与间断判读的癌检出率和阳性预测值无显著差异。
- 批阅可在维持癌检出率与阳性预测值的同时改善召回率。
核心结论
- 批阅数字筛查乳腺X线摄影(含与不含断层合成)较间断判读改善召回率,同时维持癌检出率和阳性预测值。
研究设计与样本
- 回顾性研究,回顾2015年1月至2017年6月间原始判读为批阅或间断判读的数字乳腺X线摄影(含与不含断层合成)。
- 不含断层合成:批阅9832例,间断判读49496例;含断层合成:批阅7075例,间断判读24380例。
- 比较指标包括召回率(每100例检查)、癌检出率(每1000例检查)、召回阳性预测值和活检阳性预测值。
诊断标准与关键数值
- 不含断层合成:批阅召回率9.98%、癌检出率4.27、召回阳性预测值4.40%、活检阳性预测值35.5%;间断判读分别为11.3%、4.44、3.92%、30.1%。
- 含断层合成:批阅召回率6.98%、癌检出率5.37、召回阳性预测值7.69%、活检阳性预测值38.0%;间断判读分别为8.30%、5.41、6.52%、33.3%。
- 含与不含断层合成,批阅较间断判读召回率改善(P < .001),其余指标无显著差异。
临床应用与阅片要点
- 原文结论提示批阅数字筛查乳腺X线摄影(含与不含断层合成)可在维持癌检出率和阳性预测值的同时改善召回率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare batch reading and interrupted interpretation for modern screening mammography.
METHODS: We retrospectively reviewed digital mammograms without and with tomosynthesis that were originally interpreted with batch reading or interrupted interpretation between January 2015 and June 2017. The following performance metrics were compared: recall rate (per 100 examinations), cancer detection rate (per 1,000 examinations), and positive predictive values for recall and biopsy.
RESULTS: In all, 9,832 digital mammograms were batch read, yielding a recall rate of 9.98%, cancer detection rate of 4.27, and positive predictive values for recall and biopsy of 4.40% and 35.5%, respectively. There were 49,496 digital mammograms that were read with interrupted interpretation, yielding a recall rate of 11.3%, cancer detection rate of 4.44, and positive predictive values for recall and biopsy of 3.92% and 30.1%, respectively. Of the digital mammograms with tomosynthesis, 7,075 were batch read, yielding a recall rate of 6.98%, cancer detection rate of 5.37, and positive predictive values for recall and biopsy of 7.69% and 38.0%, respectively. Of the digital mammograms with tomosynthesis, 24,380 were read with interrupted interpretation, yielding a recall rate of 8.30%, cancer detection rate of 5.41, and positive predictive values for recall and biopsy of 6.52% and 33.3%, respectively. For both digital mammograms without and with tomosynthesis, recall rates improved with batch reading compared with interrupted interpretation (P < .001), but no significant differences were seen for other metrics.
DISCUSSION: Batch reading digital mammograms without and with tomosynthesis improves recall rates while maintaining cancer detection rates and positive predictive values compared with interrupted interpretation.
引用
- Cohen EO, Lesslie M, Weaver O, et al. Batch Reading and Interrupted Interpretation of Digital Screening Mammograms Without and With Tomosynthesis. J Am Coll Radiol. 2020. PMID: 32861601. doi:10.1016/j.jacr.2020.07.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。