文献速递妇产影像US

超声弹性成像评估宫颈对足月单胎初产妇临近分娩的预测:一项前瞻性队列研究

Sonoelastographic Assessment of the Uterine Cervix in the Prediction of Imminent Delivery in Singleton Nulliparous Women Near Term: A Prospective Cohort Study.
PubMed 文献 · J Ultrasound Med · 2020-08-25

该前瞻性队列纳入398例37周至38周6天的单胎初产妇,经阴道超声弹性成像获取宫颈长度、后宫颈角、硬度比及内外口平均应变,主要结局为7天内分娩。宫颈长度和硬度比是与1周内分娩独立相关的变量,二者联合模型预测7天内分娩的AUC为0.873,优于单独使用宫颈长度或硬度比。

要点

  • 宫颈长度和硬度比是与7天内分娩独立相关的超声指标。
  • 宫颈长度联合硬度比预测7天内分娩的AUC为0.873,优于任一指标单独使用。
  • 7天内分娩者宫颈更短、后宫颈角更窄、硬度比更低、内外口平均应变更高。

诊断标准与关键数值

  • 7天内分娩者宫颈长度19.5 mm vs 未在7天内分娩者27 mm(P = .0001),宫颈长度较短。
  • 7天内分娩者后宫颈角99° vs 未在7天内分娩者102°(P = .02),后宫颈角较窄。
  • 7天内分娩者硬度比35.3 vs 未在7天内分娩者40.7(P = .0001),硬度比较低。
  • 7天内分娩者外口平均应变0.41 vs 未在7天内分娩者0.35(P = .0001),外口平均应变较高。
  • 7天内分娩者内口平均应变0.38 vs 未在7天内分娩者0.33(P = .0001),内口平均应变较高。

临床应用与阅片要点

  • 多因素logistic回归显示宫颈长度(调整OR 1.307)和硬度比(调整OR 1.227)是与1周内分娩独立相关的变量。
  • 宫颈长度联合硬度比模型预测7天内分娩的AUC为0.873,高于单独使用宫颈长度或硬度比(P ≤ .0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To explore the role of newly developed software to assess cervical sonoelastography in predicting the onset of spontaneous delivery in singleton pregnancies at term and to compare its diagnostic performance with that provided by the cervical length (CL) and posterior cervical angle (PCA).

METHODS: This work was a prospective study including nulliparous singleton pregnancies at gestational ages of 37 weeks to 38 weeks 6 days. The CL, PCA, hardness ratio (HR), and mean strain from the internal os and external os were obtained by a transvaginal ultrasound approach using semiautomatic software (E-Cervix; Samsung Medison Co, Ltd, Seoul, Korea). Multivariate logistic regression and area under the curve analyses were used to test the strength of the association and the diagnostic performance of the variables considered in predicting delivery within 7 days.

RESULTS: A total of 398 women were included, and 24.6% delivered within 7 days. The CL was shorter (19.5 versus 2 7 mm; P = .0001), PCA narrower (99° versus 102°; P = .02) HR lower (35.3 versus 40.7; P = .0001), mean strain from the external os higher (0.41 versus 0.35; P = .0001), and mean strain from the internal os higher (0.38 versus 0.33; P = .0001) higher in women who delivered within 7 days from the assessment. At the multivariable logistic regression analysis, the CL (adjusted odds ratio, 1.307) and HR (adjusted odds ratio, 1.227) were the only variables independently associated with delivery within 1 week. A model combining the CL and HR showed an area under the curve of 0.873 in predicting delivery within 7 days, higher than that obtained by using the CL and HR singularly (P ≤ .0001).

CONCLUSIONS: The HR assessed by sonoelastography improves the efficacy of the CL in predicting imminent delivery in nulliparous women close to term.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Rizzo G, Pietrolucci ME, Mappa I, et al. Sonoelastographic Assessment of the Uterine Cervix in the Prediction of Imminent Delivery in Singleton Nulliparous Women Near Term: A Prospective Cohort Study. J Ultrasound Med. 2020. PMID: 32840895. doi:10.1002/jum.15434

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。