O-RADS、GI-RADS与IOTA简单规则在附件肿块诊断中的恶性率、有效性和可靠性比较

Comparison of O-RADS, GI-RADS, and IOTA simple rules regarding malignancy rate, validity, and reliability for diagnosis of adnexal masses.
PubMed 文献 · Eur Radiol · 2020-08-18

这项回顾性多中心研究纳入2016年5月至2019年12月间609例女性647个附件肿块,由5名放射科顾问医师独立按O-RADS、GI-RADS和IOTA简单规则分类,以病理和充分随访为参考标准。O-RADS对恶性的敏感度显著高于GI-RADS和IOTA(96.8% vs 92.7%和92.1%),特异度略低但无显著差异,观察者间一致性相似。

要点

  • O-RADS对附件肿块恶性的敏感度显著高于GI-RADS和IOTA简单规则(96.8% vs 92.7%和92.1%)。
  • 三种分类系统特异度略低但无显著差异(92.8% vs 93.6%和93.2%,p>0.05)。
  • O-RADS、GI-RADS和IOTA的观察者间一致性相似(κ=0.77、0.69和0.63),O-RADS有偏高的趋势。

核心结论

  • O-RADS与GI-RADS和IOTA简单规则相比表现良好,O-RADS敏感度更高而特异度和可靠性相对相似。

研究设计与样本

  • 回顾性多中心研究,纳入2016年5月至2019年12月经超声检出附件肿块的连续女性。
  • 共609例女性(平均年龄48±13.7岁,范围18-72岁)的647个附件肿块,其中178个恶性、469个良性。
  • 5名经验丰富的放射科顾问医师独立按O-RADS、GI-RADS和IOTA简单规则对每个附件肿块进行分类。
  • 以病理和充分随访为参考标准计算三种超声分类系统的有效性,采用Kappa统计评估观察者间一致性。

诊断标准与关键数值

  • O-RADS对恶性的敏感度为96.8%,GI-RADS为92.7%,IOTA简单规则为92.1%;O-RADS显著高于GI-RADS(p=0.003)和IOTA(p=0.0007)。
  • O-RADS特异度为92.8%,GI-RADS为93.6%,IOTA为93.2%;O-RADS略低但无显著差异(p>0.05)。
  • O-RADS、GI-RADS和IOTA的总体观察者间一致性κ分别为0.77、0.69和0.63,O-RADS有高于GI-RADS和IOTA的趋势。
  • O-RADS和IOTA的恶性率与既往文献推荐率相当,GI-RADS的恶性率更高。

临床应用与阅片要点

  • O-RADS对附件肿块恶性诊断的敏感度高于GI-RADS和IOTA简单规则,特异度和观察者间一致性与两者相对相似。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The American College of Radiology (ACR) recently published the ovarian-adnexal reporting and data system (O-RADS) to provide guidelines to physicians who interpret ultrasound (US) examinations of adnexal masses (AM). This study aimed to compare the O-RADS with two other well-established US classification systems for diagnosis of AM.

METHODS: This retrospective multicenter study between May 2016 and December 2019 assessed consecutive women with AM detected by the US. Five experienced consultant radiologists independently categorized each AM according to O-RADS, gynecologic imaging reporting and data system (GI-RADS), and international ovarian tumor analysis (IOTA) simple rules. Pathology and adequate follow-up were used as reference standards for calculating the validity of three US classification systems for diagnosis of AM. Kappa statistics were used to assess the inter-reviewer agreement (IRA).

RESULTS: A total of 609 women (mean age, 48 ± 13.7 years; range, 18-72 years) with 647 AM were included. Of the 647 AM, 178 were malignant and 469 were benign. Malignancy rates were comparable to recommended rates by previous literature in O-RADS and IOTA, but higher in GI-RADS. O-RADS had significantly higher sensitivity for malignancy than GI-RAD and IOTA (p = 0.003 and 0.0007, respectively), but non-significant slightly lower specificity (p > 0.05). O-RADS, GI-RADS, and IOTA showed similar overall IRA (κ = 0.77, 0.69, and 0.63, respectively) with a tendency toward higher IRA with O-RADS than with GI-RADS and IOTA.

CONCLUSIONS: O-RADS compares favorably with GI-RADS and IOTA. O-RADS had higher sensitivity than GI-RADS and IOTA simple rules with relatively similar specificity and reliability.

KEY POINTS: • The malignancy rates were comparable to recommended rates by previous literature in O-RADS and IOTA, but higher in GI-RADS. • The O-RADS had significantly higher sensitivity for malignancy than GI-RADS and IOTA (96.8% vs 92.7% and 92.1%; p = 0.003 and 0.0007, respectively), but non-significant slightly lower specificity (92.8% vs 93.6% and 93.2%, respectively; p > 0.05). • The O-RADS, GI-RADS, and IOTA showed similar overall inter-reviewer agreement (IRA) (κ = 0.77, 0.69, and 0.63, respectively), with a tendency toward higher IRA with O-RADS than with GI-RADS and IOTA.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Basha MAA, Metwally MI, Gamil SA, et al. Comparison of O-RADS, GI-RADS, and IOTA simple rules regarding malignancy rate, validity, and reliability for diagnosis of adnexal masses. Eur Radiol. 2020. PMID: 32809166. doi:10.1007/s00330-020-07143-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。