开放式胎儿显微神经外科修复开放性脊柱裂过程中脐动脉、大脑中动脉、脑胎盘比率及静脉导管的超声多普勒变化
前瞻性研究纳入44例接受微型子宫切开术(直径15 mm)开放式胎儿显微神经外科修复开放性脊柱裂的胎儿,术中多普勒可全部成功获取。与术前相比,术中大脑中动脉搏动指数低于第5百分位、脑胎盘比率低于第5百分位及静脉导管搏动指数高于第95百分位的胎儿比例显著升高,脐动脉搏动指数高于第95百分位的比例无显著升高,所有异常多普勒参数术后均恢复正常。
要点
- 术中可出现大脑中动脉搏动指数低于第5百分位、脑胎盘比率低于第5百分位及静脉导管搏动指数高于第95百分位的比例升高。
- 脐动脉搏动指数高于第95百分位的比例术中较术前无显著升高。
- 术中未见脐动脉舒张末期血流缺失或反向,也未见静脉导管a波缺失或反向。
关键影像表现/征象
- 术中所有时间点均成功获得多普勒记录。
- 术中未见脐动脉舒张末期血流缺失或反向。
- 术中未见静脉导管a波缺失或反向。
- 所有异常多普勒参数在术后均恢复正常。
诊断标准与关键数值
- 脐动脉搏动指数高于第95百分位视为异常。
- 静脉导管搏动指数高于第95百分位视为异常。
- 大脑中动脉搏动指数低于第5百分位视为异常。
- 脑胎盘比率低于第5百分位视为异常。
- 术中大脑中动脉搏动指数低于第5百分位的胎儿比例63.6% vs 术前13.6%(P < 0.001)。
临床应用与阅片要点
- 开放式胎儿脊柱裂修复术中可连续行脐动脉、大脑中动脉及静脉导管多普勒监测。
- 术中大脑中动脉搏动指数低于第5百分位、脑胎盘比率低于第5百分位及静脉导管搏动指数高于第95百分位的比例较术前升高。
- 术中脐动脉搏动指数高于第95百分位的比例较术前无显著升高(P = 0.12)。
- 作者认为术中轻度多普勒变化可能是胎儿对手术应激的适应表现。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To describe changes in fetal Doppler parameters during a novel technique for open fetal microneurosurgery for open spina bifida (OSB) repair.
METHODS: This was a prospective study of 44 fetuses undergoing open fetal surgery for OSB repair using a novel microneurosurgery approach that is characterized by a mini-hysterotomy (diameter of 15 mm), minimal fetal manipulation and maintenance of a constant normal amniotic fluid volume throughout the procedure. Doppler velocimetry of the umbilical artery (UA), fetal middle cerebral artery (MCA) and ductus venosus (DV) was performed before the start of surgery and at prespecified timepoints during fetal surgery. UA pulsatility index (PI) > 95th percentile, DV-PI > 95th percentile, MCA-PI < 5th percentile and cerebroplacental ratio (CPR) < 5th percentile were considered abnormal.
RESULTS: Median gestational age at fetal surgery was 25.2 weeks (range, 22.9-27.9 weeks). Doppler recordings were successfully obtained in all cases during all timepoints throughout the surgery. As compared with Doppler values before surgery, there was a significant increase in the proportion of fetuses with MCA-PI < 5th percentile (63.6% vs 13.6%; P < 0.001), CPR < 5th percentile (65.9% vs 15.9%; P < 0.001) and DV-PI > 95th percentile (22.7% vs 0%; P = 0.01) and a non-significant increase in the proportion of fetuses with UA-PI > 95th percentile (11.4% vs 0%; P = 0.12) during fetal surgery. None of the fetuses showed absent or reversed end-diastolic velocity in the UA or absent or reversed DV a-wave at any stage during OSB repair. All abnormal Doppler parameters returned to normal after surgery.
CONCLUSIONS: During open fetal surgery for OSB repair, a small hysterotomy, reduced fetal manipulation and maintenance of a normal amniotic fluid volume seem to prevent severe fetal Doppler abnormalities. The mild Doppler changes observed during fetal surgery could be a manifestation of fetal adaptation to the stress of fetal surgery. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Cruz-Martínez R, Gámez-Varela A, Cruz-Lemini M, et al. Doppler changes in umbilical artery, middle cerebral artery, cerebroplacental ratio and ductus venosus during open fetal microneurosurgery for intrauterine open spina bifida repair. Ultrasound Obstet Gynecol. 2021. PMID: 32798234. doi:10.1002/uog.22177
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。