文献速递妇产影像US

不同生长标准对大于胎龄儿新生儿的预测

Prediction of Large-for-Gestational-Age Neonates by Different Growth Standards.
PubMed 文献 · J Ultrasound Med · 2020-08-29

本研究为前瞻性研究的二次分析,纳入1054例单胎无畸形妊娠,于26-36周行生长超声,比较Hadlock、NICHD和FMF三种生长标准预测大于胎龄儿(LGA)及不良新生儿结局的准确性。NICHD和FMF标准的AUC均高于Hadlock,敏感度更高但特异度较低;三种标准对不良新生儿结局的预测均不佳。

要点

  • NICHD和FMF标准预测LGA的AUC分别为0.79和0.81,均高于Hadlock的0.64。
  • FMF和NICHD标准敏感度更高(77.2%和72.4% vs Hadlock 30.1%),但Hadlock特异度更高(97.5% vs 88.5%和85.4%)。
  • 三种标准对不良新生儿结局的预测均不佳。

核心结论

  • NICHD和FMF标准可能较Hadlock图表提高LGA的检出率,但可能增加产科干预。

研究设计与样本

  • 前瞻性研究的二次分析,纳入1054例单胎无畸形妊娠,于26-36周行生长超声。
  • 以出生体重>90百分位诊断为LGA,比较Hadlock、NICHD和FMF三种标准预测LGA及不良新生儿结局的效能。

诊断标准与关键数值

  • 估计胎儿体重>90百分位分别按NICHD、FMF和Hadlock图表疑诊LGA。
  • NICHD标准预测LGA的AUC为0.79(95%CI 0.75-0.83),FMF为0.81(95%CI 0.77-0.85),Hadlock为0.64(95%CI 0.6-0.68),NICHD和FMF均优于Hadlock(P<.001)。
  • FMF、NICHD和Hadlock预测LGA的敏感度分别为77.2%、72.4%和30.1%,特异度分别为85.4%、88.5%和97.5%。
  • 三种标准对不良新生儿结局(NICU入住、Ph<7.1、5分钟Apgar<7、惊厥和新生儿死亡)的预测均不佳。

临床应用与阅片要点

  • 采用NICHD或FMF标准可能提高LGA检出率,但需注意可能增加产科干预。
  • Hadlock标准特异度高但敏感度低,可能漏诊较多LGA。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Compare the accuracy of the Hadlock, the NICHD, and the Fetal Medicine Foundation (FMF) charts to detect large-for-gestational-age (LGA) and adverse neonatal outcomes (as a secondary outcome).

METHODS: This is a secondary analysis from a prospective study that included singleton non-anomalous gestations with growth ultrasound at 26-36 weeks. LGA was suspected with estimated fetal weight > 90th percentile by the NICHD, FMF, and Hadlock charts. LGA was diagnosed with birth weight > 90th percentile. We tested the performance of these charts to detect LGA and adverse neonatal outcomes (neonatal intensive care unit admission, Ph < 7.1, Apgar <7 at 5 minutes, seizures, and neonatal death) by calculating the area under the curve, sensitivity, specificity, positive predictive value, and negative predictive value.

RESULTS: Of 1054 pregnancies, 123 neonates (12%) developed LGA. LGA was suspected in 58 (5.5%) by Hadlock, 229 (21.7%) by NICHD standard, and 231 (22%) by FMF chart. The NICHD standard (AUC: .79; 95% CI: .75-.83 vs. AUC .64; 95%CI: .6-.68; p = < .001) and FMF chart (AUC: .81 95% CI: .77-.85 vs. AUC .64; 95%CI: .6-.68; p = < .001) were more accurate than Hadlock. The FMF and NICHD had higher sensitivity (77.2 vs. 72.4 vs. 30.1%) but Hadlock had higher specificity for LGA (97.5 vs. 88.5 vs. 85.4%). All standards were poor predictors for adverse neonatal outcomes.

CONCLUSIONS: The NICHD and the FMF standards may increase the detection rate of LGA in comparison to the Hadlock chart. However, this may increase obstetrical interventions.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Duncan JR, Odibo L, Hoover EA, et al. Prediction of Large-for-Gestational-Age Neonates by Different Growth Standards. J Ultrasound Med. 2020. PMID: 32860453. doi:10.1002/jum.15470

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。