基于体素内不相干运动模型扩散加权成像对胎盘植入的功能性诊断
本研究纳入25例胎盘植入孕妇与24例正常胎盘孕妇,行3-T磁共振IVIM-DWI检查并计算灌注分数f、伪扩散系数D*及扩散系数D。胎盘植入组整体ROI及植入区ROI的f与D*均显著高于对照,f与D*的ROC曲线下面积分别为0.93与0.79,提示IVIM可定量评估胎盘植入的灌注增高并可能用于预测胎盘植入。
要点
- 胎盘植入整体ROI的f为(45.0±7.63)%、D*为(11.64±2.15)mm2/s,高于正常胎盘的(31.85±5.96)%、(9.04±3.13)mm2/s。
- 植入区ROI的f为54.8%、D*为14.03 mm2/s,高于非植入区ROI的37.4%、11.4 mm2/s。
- f与D*的ROC曲线下面积分别为0.93与0.79,D值在胎盘植入与正常胎盘间无显著差异。
诊断标准与关键数值
- 胎盘植入整体ROI的f为(45.0±7.63)%、D*为(11.64±2.15)mm2/s,正常胎盘整体ROI的f为(31.85±5.96)%、D*为(9.04±3.13)mm2/s,两组f与D*差异均p<0.05。
- 胎盘植入植入区ROI的f为54.8%、D*为14.03 mm2/s,非植入区ROI的f为37.4%、D*为11.4 mm2/s,两组f与D*差异均p<0.05。
- 胎盘植入整体ROI与正常胎盘整体ROI的D值差异无统计学意义(p>0.05),植入区ROI与非植入区ROI的D值差异亦无统计学意义(p>0.05)。
- f与D*的ROC曲线下面积分别为0.93与0.79。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the diagnostic value of intravoxel incoherent motion (IVIM) DWI for placenta accreta by comparing diffusion and perfusion characteristics of placentas with accreta lesions (APs) with those of normal placentas (NPs).
METHODS: Twenty-five pregnant women with AP and 24 with NP underwent 3-T magnetic resonance examinations with IVIM-DWI. The perfusion percentage (f), pseudo-diffusion coefficient (D*), and diffusion coefficient (D) values were calculated from different ROIs: the entire-plane of the AP (AP-ROI) and NP (NP-ROI) and the implanted (IR-ROI) and non-implanted region (NIR-ROI) of the AP. The AP-ROIs and NP-ROIs were compared using covariance analysis; the IR-ROIs and NIR-ROIs were compared using the Wilcoxon signed-rank test. ROC curves were produced to evaluate the parameters for predicting placenta accreta.
RESULTS: The f and D* values for the AP-ROIs ([45.0 ± 7.63]%, [11.64 ± 2.15]mm2/s) were significantly higher than those for the NP-ROIs ([31.85 ± 5.96]%, [9.04 ± 3.13]mm2/s) (both p < 0.05); the IR-ROIs (54.8%, 14.03 mm2/s) were also significantly higher than the NIR-ROIs (37.4%, 11.4 mm2/s) (both p < 0.05). No significant differences were found between the D values of the AP-ROIs and NP-ROIs (p > 0.05) or of the IR-ROIs and NIR-ROIs (p > 0.05). The areas under the curve for f and D* of the ROC curves were 0.93 and 0.79, respectively.
CONCLUSIONS: These results suggest that the IVIM parameters f and D* can be used to quantitatively evaluate the higher perfusion of AP when compared with NP. Furthermore, IVIM may be a useful functional diagnostic technique to predict placenta accreta.
KEY POINTS: • Intravoxel incoherent motion (IVIM) may be a useful diagnostic technique to quantitatively estimate the perfusion of the placenta. • The perfusion percentage (f) and pseudo-diffusion coefficient (D*) values differed significantly between placentas with accreta lesions and normal placentas. • ROC curves showed that perfusion percentage (f) and pseudo-diffusion coefficient (D*) values could accurately predict placenta accreta.
引用
- Bao Y, Pang Y, Sun Z, et al. Functional diagnosis of placenta accreta by intravoxel incoherent motion model diffusion-weighted imaging. Eur Radiol. 2020. PMID: 32862290. doi:10.1007/s00330-020-07200-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。