文献速递泌尿生殖腹部MRPET

多参数前列腺MRI与68Ga-PSMA PET-CT在新诊断前列腺癌淋巴结受累及包膜外侵犯评估中的诊断效能比较

Comparing the Diagnostic Performance of Multiparametric Prostate MRI Versus 68Ga-PSMA PET-CT in the Evaluation Lymph Node Involvement and Extraprostatic Extension.
PubMed 文献 · Acad Radiol · 2020-08-04

本研究纳入39例接受根治性前列腺切除及扩大盆腔淋巴结清扫的新诊断前列腺癌患者,比较mpMRI与68Ga-PSMA PET-CT对包膜外侵犯和淋巴结转移的诊断效能。MRI检测包膜外侵犯敏感度56.2%、特异度82.6%;PET分别为62.5%、60.8%。两者检测转移淋巴结的敏感度均低(MRI 36.3%,PET 18.1%)。

要点

  • mpMRI检测包膜外侵犯敏感度56.2%、特异度82.6%,PET-CT敏感度62.5%、特异度60.8%。
  • MRI检测转移淋巴结敏感度36.3%、特异度99.6%,PET-CT敏感度18.1%、特异度99.4%。
  • 两种方法检测转移淋巴结的敏感度均低,PET-CT在包膜外侵犯评估中敏感度略高但特异度较低。

诊断标准与关键数值

  • MRI检测包膜外侵犯:敏感度56.2%,特异度82.6%,阳性预测值69.2%,阴性预测值73.0%。
  • PET-CT检测包膜外侵犯:敏感度62.5%,特异度60.8%,阳性预测值52.6%,阴性预测值70%。
  • MRI检测转移淋巴结:敏感度36.3%,特异度99.6%,阳性预测值57.1%,阴性预测值99.0%。
  • PET-CT检测转移淋巴结:敏感度18.1%,特异度99.4%,阳性预测值33.3%,阴性预测值98.8%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Our research aims to compare the efficacy of PET and MRI for lymph node metastasis and extraprostatic extension in cases with newly diagnosed prostate cancer undergoing radical prostatectomy with extended pelvic lymph node dissection.

METHODS: Thirty-nine cases who underwent radical prostatectomy with pelvic lymph node dissection between June 2015 and January 2020 were included in the study. Patients with gallium (ga-68 Prostate-specific membrane antigen (PSMA) PET) PSMA PET-CT and multiparametric (mp) prostate MRI performed according to PIRADS v2 criteria in our clinic were included.

RESULTS: The extraprostatic extension was observed in 16 cases. The sensitivity of MR in detecting extracapsular invasion was calculated as 56.2%, specificity 82.6%, positive predictive value (PPV) 69.2%, negative predictive value (NPV) 73.0%. The sensitivity of PET was 62.5%, specificity 60.8%, PPV 52.6%, NPV 70%. Eleven lymph node metastases were observed in nine cases. The sensitivity, specificity, PPV and NPV of metastatic lymph node detection were; 36.3%, 99.6%, 57.1%, 99.0% for MRI and; 18.1%, 99.4%, 33.3%, 98.8% for PET CT, respectively.

CONCLUSION: Mp prostate MRI showed low sensitivity and high specificity compared to PSMA PET CT in extracapsular invasion evaluation. The sensitivity of both modalities in the detection of metastatic lymph nodes was low.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Arslan A, Karaarslan E, Güner AL, et al. Comparing the Diagnostic Performance of Multiparametric Prostate MRI Versus 68Ga-PSMA PET-CT in the Evaluation Lymph Node Involvement and Extraprostatic Extension. Acad Radiol. 2020. PMID: 32768351. doi:10.1016/j.acra.2020.07.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。