双参数MRI纹理分析用于评估前列腺癌患者的侵袭性
本研究纳入116例经根治性前列腺切除术或活检证实为前列腺腺癌的患者,分为训练集(65例)和验证集(51例),所有患者术前行3T-MRI,在轴位T2WI和ADC图上进行全肿瘤体积纹理分析。训练集中ADC图GLCM熵是GS的唯一显著指标(R²=0.4227,P=0.0034),其鉴别CSC(GS≥7)的AUC为0.825,最大准确率82%、敏感度86%、特异度71%;以2.92为截断值在验证集上准确率92%、敏感度98%、特异度70%。
要点
- ADC图GLCM熵与前列腺癌Gleason评分相关,训练集R²=0.4227,P=0.0034。
- ADC图GLCM熵鉴别临床显著癌(GS≥7)的AUC为0.825(95%CI 0.711-0.907)。
- 截断值2.92在验证集鉴别CSC的准确率92%、敏感度98%、特异度70%。
关键影像表现/征象
- 纹理分析在轴位T2WI和ADC图上进行,覆盖全肿瘤体积。
- 训练集中ADC图GLCM熵是GS的唯一显著指标,决定系数R²为0.4227,P=0.0034。
诊断标准与关键数值
- ADC图GLCM熵鉴别临床显著癌(GS≥7)与非临床显著癌的AUC为0.825(95%CI 0.711-0.907),最大准确率82%、敏感度86%、特异度71%。
- 以2.92为截断值应用于验证集,鉴别CSC的准确率92%、敏感度98%、特异度70%。
临床应用与阅片要点
- ADC图GLCM熵可作为评估前列腺癌Gleason评分及鉴别临床显著癌的纹理参数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the association between texture parameters based on bi-parametric MRI and Gleason score (GS) in patients with prostate cancer (PCa) and to evaluate diagnostic performance of any significant parameter for discriminating clinically significant cancer (CSC, GS ≥ 7) from non-CSC.
METHODS: A total of 116 patients who had been confirmed as prostate adenocarcinoma by radical prostatectomy or biopsy were divided into a training (n = 65) and a validation dataset (n = 51). All of the patients underwent preoperative 3T-MRI. Texture analysis was performed on axial T2WI and ADC maps (generated from b values, 0 and 1000 s/mm2) using dedicated software to cover the whole tumor volume. The correlation coefficient was calculated to evaluate the association between texture parameters and GS, and subsequent multiple regression analyses were applied for the significant parameters. To extract an optimal cut-off value for prediction of CSC, ROC curve analysis was performed.
RESULTS: In the training dataset, gray-level co-occurrence matrix (GLCM) entropy on ADC map was the only significant indicator for GS (coefficient of determination R2, 0.4227, P = 0.0034). The AUC of GLCM entropy on ADC map was 0.825 (95% CI 0.711-0.907) with a maximum accuracy of 82%, a sensitivity of 86%, a specificity of 71%. When a cut-off value of 2.92 was applied to the validation dataset, it showed an accuracy of 92%, a sensitivity of 98%, and a specificity of 70%.
CONCLUSION: GLCM entropy on ADC map was associated with GS in patients with PCa and its estimated accuracy for discriminating CSC from non-CSC was 82%.
引用
- Baek TW, Kim SH, Park SJ, et al. Texture analysis on bi-parametric MRI for evaluation of aggressiveness in patients with prostate cancer. Abdom Radiol (NY). 2020. PMID: 32740864. doi:10.1007/s00261-020-02683-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。