文献速递泌尿生殖腹部MR

VI-RADS:多机构多阅片者诊断准确性与观察者间一致性研究

VI-RADS: Multiinstitutional Multireader Diagnostic Accuracy and Interobserver Agreement Study.
PubMed 文献 · AJR Am J Roentgenol · 2020-07-29

多机构回顾性研究纳入91例膀胱癌患者,7名不同经验放射科医师按VI-RADS评分。经验丰富者间一致性中等至高度(κ=0.60-0.80),所有读者汇总AUC为0.87;以VI-RADS≥4为肌层浸润性膀胱癌阈值,经验丰富者汇总敏感度74.1%、特异度94.1%。

要点

  • VI-RADS评分在不同经验水平放射科医师间一致性中等至高度,汇总AUC为0.87。
  • 以VI-RADS≥4为肌层浸润性膀胱癌阈值,经验丰富者汇总敏感度74.1%、特异度94.1%。
  • VI-RADS可能有助于确定经尿道膀胱肿瘤电切术的切除深度和范围。

诊断标准与关键数值

  • 以VI-RADS评分≥4为肌层浸润性膀胱癌阈值,经验丰富读者汇总敏感度74.1%(范围66.0-80.9%)、特异度94.1%(范围88.6-97.7%)。
  • 以VI-RADS评分≥4为肌层浸润性膀胱癌阈值,无经验读者汇总敏感度63.9%(范围59.6-68.1%)、特异度86.4%(范围84.1-88.6%)。
  • 以VI-RADS评分≥3为阈值,经验丰富读者汇总敏感度83.4%(范围80.9-85.1%)、特异度77.3%(范围61.4-88.6%)。
  • 以VI-RADS评分≥3为阈值,无经验读者汇总敏感度82.0%(范围80.9-83.0%)、特异度73.9%(范围72.7-75.0%)。

临床应用与阅片要点

  • 经验丰富读者间一致性中等至高度(κ=0.60-0.80),两名无经验读者间一致性高度(κ=0.67),经验丰富与无经验读者间一致性中等至高度(κ=0.55-0.75)。
  • 经验丰富读者汇总AUC为0.88(范围0.82-0.91),无经验读者汇总AUC为0.84(范围0.83-0.85),所有读者汇总AUC为0.87。
  • 作者指出VI-RADS可能有助于确定经尿道膀胱肿瘤电切术的切除深度和范围,降低并发症风险并提高病理诊断准确性。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. The Vesical Imaging Reporting and Data System (VI-RADS), based on multiparametric MRI (mpMRI), was developed to provide accurate information for the diagnosis of muscle-invasive bladder cancer (MIBC). OBJECTIVE. The purpose of our study was to evaluate the interobserver agreement and diagnostic performance of VI-RADS among readers with different levels of experience. METHODS. This retrospective study included 91 consecutive patients who underwent mpMRI before transurethral resection of bladder tumor (TURBT) from July 2010 through August 2018. After attending a training session, seven radiologists (five radiologists experienced in bladder MRI and two inexperienced radiologists) reviewed and scored all MRI examinations according to VI-RADS. The interobserver agreement was assessed by kappa statistics. ROC analysis was used to evaluate the diagnostic performance for MIBC. AUCs were estimated. RESULTS. Among 91 patients (72 men and 19 women; mean age ± SD, 73.2 ± 10.2 years), 48 (52.7%) had MIBC and 43 (47.3%) had non-muscle-invasive bladder cancer. Sixty-eight patients were treated with TURBT, and 23 were treated with radical cystectomy. Interobserver agreement was moderate to substantial (κ = 0.60-0.80) among the experienced readers, substantial (κ = 0.67) between the two inexperienced readers, and moderate to substantial (κ = 0.55-0.75) between the experienced and inexperienced readers. The pooled AUC was 0.88 (range, 0.82-0.91) for experienced readers and 0.84 (range, 0.83-0.85) for inexperienced readers, and 0.87 for all readers. Using a VI-RADS score of 4 or greater as the cutoff value for MIBC, the pooled sensitivity and specificity were 74.1% (range, 66.0-80.9%) and 94.1% (range, 88.6-97.7%) for experienced readers and 63.9% (range, 59.6-68.1%) and 86.4% (range, 84.1-88.6%) for inexperienced readers. Using a VI-RADS score of 3 or greater as the cutoff value, the pooled sensitivity and specificity were 83.4% (range, 80.9-85.1%) and 77.3% (range, 61.4-88.6%) for experienced readers and 82.0% (range, 80.9-83.0%) and 73.9% (range, 72.7-75.0%) for inexperienced readers. CONCLUSION. We observed moderate to substantial interobserver agreement and a pooled AUC of 0.87 among radiologists of different levels of expertise using VI-RADS. CLINICAL IMPACT. VI-RADS could help determine the depth and range of excision in TURBT, decreasing the risk of complications and enhancing the accuracy of pathologic diagnosis.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Ueno Y, Tamada T, Takeuchi M, et al. VI-RADS: Multiinstitutional Multireader Diagnostic Accuracy and Interobserver Agreement Study. AJR Am J Roentgenol. 2020. PMID: 32755215. doi:10.2214/AJR.20.23604

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。