文献速递技术与安全US

探究亚微米相变液滴在肿瘤内的蓄积

Investigating the Accumulation of Submicron Phase-Change Droplets in Tumors.
PubMed 文献 · Ultrasound Med Biol · 2020-07-27

本研究开发了一种在诊断安全限内使用的超声成像脉冲序列,通过成像-汽化-成像及脉冲减影方法,选择性检测荷瘤小鼠肿瘤内亚微米全氟丁烷液滴的外渗。肿瘤内液滴外渗信号中位数相对于总信号为37±5%,肾脏为-2±8%(p < 0.001),为挥发性相变液滴作为下一代超声诊疗剂提供了进展。

要点

  • 亚微米相变液滴可被动外渗并蓄积于实体瘤,汽化后作为血管外特异性超声对比剂。
  • 成像-汽化-成像脉冲序列结合脉冲减影可在诊断安全限内选择性检测肿瘤内液滴外渗。
  • 荷瘤小鼠肿瘤内液滴外渗信号中位数相对于总信号为37±5%,肾脏为-2±8%(p < 0.001)。

核心结论

  • 在诊断安全限内开发的超声成像脉冲序列可选择性检测肿瘤内亚微米全氟丁烷液滴的外渗信号。

研究设计与样本

  • 荷瘤小鼠经注射亚微米全氟丁烷液滴后,采用成像-汽化-成像序列进行超声 interrogation,并以脉冲减影方法估计液滴外渗信号。

关键影像表现/征象

  • 脉冲减影方法估计的肿瘤内液滴外渗信号中位数相对于总信号为37±5%,肾脏为-2±8%(p < 0.001)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Submicron phase-change droplets are an emerging class of ultrasound contrast agent. Compared with microbubbles, their relatively small size and increased stability offer the potential to passively extravasate and accumulate in solid tumors through the enhanced permeability and retention effect. Under exposure to sufficiently powerful ultrasound, these droplets can convert into in situ gas microbubbles and thus be used as an extravascular-specific contrast agent. However, in vivo imaging methods to detect extravasated droplets have yet to be established. Here, we develop an ultrasound imaging pulse sequence within diagnostic safety limits to selectively detect droplet extravasation in tumors. Tumor-bearing mice were injected with submicron perfluorobutane droplets and interrogated with our imaging-vaporization-imaging sequence. By use of a pulse subtraction method, median droplet extravasation signal relative to the total signal within the tumor was estimated to be Etumor=37±5% compared with the kidney Ekidney=-2±8% (p < 0.001). This work contributes toward the advancement of volatile phase-shift droplets as a next-generation ultrasound agent for imaging and therapy.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Helfield BL, Yoo K, Liu J, et al. Investigating the Accumulation of Submicron Phase-Change Droplets in Tumors. Ultrasound Med Biol. 2020. PMID: 32732167. doi:10.1016/j.ultrasmedbio.2020.06.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。