文献速递腹部技术与安全US

应用声辐射力脉冲剪切波弹性成像测量脾硬度预测脾肿大病因

Spleen stiffness measurement by shear wave elastography using acoustic radiation force impulse in predicting the etiology of splenomegaly.
PubMed 文献 · Abdom Radiol (NY) · 2020-08-08

研究纳入61例初治脾肿大患者和20例健康对照,用声辐射力脉冲剪切波弹性成像测量脾硬度(剪切波速度)。肝门静脉性组中位剪切波速度3.85 m/s、骨髓增殖性组3.42 m/s,均高于感染性组2.66 m/s和对照组2.22 m/s;剪切波速度似乎有助于预测脾肿大病因。

要点

  • 脾肿大患者脾剪切波速度高于健康对照,肝门静脉性和骨髓增殖性病因者又高于感染性病因者。
  • 鉴别肝门静脉性与感染性病因的剪切波速度阈值为3.02,敏感度100%、特异度100%。
  • 鉴别骨髓增殖性与感染性病因的阈值为2.84,敏感度91.3%、特异度88.2%。

核心结论

  • 脾肿大患者弹性成像所测脾硬度高于健康受试者;剪切波速度似乎有助于预测脾肿大病因。

研究设计与样本

  • 研究纳入61例初治脾肿大患者,对照组为20例无糖尿病、高血压、饮酒史及肝肾疾病生化或超声证据的健康受试者。
  • 由对受试者设盲的放射科医师完成B模式超声和弹性成像检查,用声辐射力脉冲剪切波弹性成像测量脾硬度,剪切波速度以m/s表示。
  • 脾肿大患者按病因分为肝门静脉性组(n=21)、骨髓增殖性组(n=23)和感染性组(n=17)。

关键影像表现/征象

  • 脾肿大各组与对照组年龄、性别可比;脾肿大各组脾脏大小高于对照组。
  • 中位剪切波速度:肝门静脉性组3.85 m/s、骨髓增殖性组3.42 m/s,高于感染性组2.66 m/s和对照组2.22 m/s。
  • 各组的剪切波速度与脾脏大小之间相关性均无统计学显著意义。

诊断标准与关键数值

  • 鉴别肝门静脉性与骨髓增殖性病因的阈值为3.42,敏感度80.9%、特异度56.5%。
  • 鉴别肝门静脉性与感染性病因的阈值为3.02,敏感度100%、特异度100%。
  • 鉴别骨髓增殖性与感染性病因的阈值为2.84,敏感度91.3%、特异度88.2%。

临床应用与阅片要点

  • 剪切波速度似乎有助于预测脾肿大病因,可结合病因分组解读脾硬度测值。
  • 鉴别肝门静脉性与骨髓增殖性病因时阈值3.42的特异度仅56.5%,需结合临床判断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To measure spleen stiffness by shear wave elastography (SWE) using acoustic radiation force impulse (ARFI) in patients with splenomegaly and to evaluate utility of elastography technique in identifying etiology of splenomegaly.

METHODS: Sixty-one treatment-naïve patients with splenomegaly were enrolled. The control group consisted of 20 healthy subjects without history of any disease including diabetes and hypertension, alcohol consumption, or biochemical or ultrasonographic findings indicating hepatic and renal diseases. B-mode ultrasonography and elastographic examinations were performed by a radiologist blinded to the participants. Spleen stiffness was measured by SWE using ARFI. Shear wave velocity (SWV) values were given in m/s.

RESULTS: Splenomegaly patients were assigned into three groups according to their etiologies as hepatoportal (n = 21), myeloproliferative (n = 23), and infectious (n = 17). Splenomegaly groups and control group were comparable regarding age and sex. Spleen size was higher in the splenomegaly groups than in the controls. Median SWV was significantly higher in the hepatoportal (3.85 m/s) and myeloproliferative (3.42 m/s) groups than in the infectious (2.66 m/s) and control (2.22 m/s) groups. The correlation between SWV and spleen size was not significant in any of the groups. The cut-off value was 3.42 (sensitivity 80.9%, specificity 56.5%) in distinguishing hepatoportal from myeloproliferative etiology; 3.02 (sensitivity 100%, specificity 100%) in distinguishing hepatoportal from infectious etiology; and 2.84 (sensitivity 91.3%, specificity 88.2%) in distinguishing myeloproliferative from infectious etiology.

CONCLUSION: Spleen stiffness measured by elastographic techniques in splenomegaly patients was higher than that in healthy subjects. SWV appeared to be beneficial in predicting the etiology of splenomegaly.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Yalçın K, Demir BÇ. Spleen stiffness measurement by shear wave elastography using acoustic radiation force impulse in predicting the etiology of splenomegaly. Abdom Radiol (NY). 2020. PMID: 32770399. doi:10.1007/s00261-020-02649-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。