磁共振成像影像组学分析可术前预测无功能胰腺神经内分泌肿瘤的G1与G2/3分级
本研究回顾性纳入157例手术切除且病理证实的无功能胰腺神经内分泌肿瘤患者,基于动脉期和门静脉期MRI提取影像组学特征构建rad-score。rad-score由7个特征组成,与肿瘤分级显著相关,每增加1分,G2/3风险增加35%,AUC为0.775,最佳截断值为0.41。作者认为rad-score可能作为无创工具用于无功能胰腺神经内分泌肿瘤的术前分级鉴别。
要点
- MRI影像组学评分(rad-score)由7个特征构成,与无功能胰腺神经内分泌肿瘤分级显著相关。
- rad-score每增加1分,G2/3风险增加35%,AUC为0.775,最佳截断值0.41。
- 阈值概率高于0.3时,rad-score鉴别G1与G2/3的决策曲线获益优于全治或全不治方案。
核心结论
- MRI rad-score与无功能胰腺神经内分泌肿瘤分级显著相关,可能作为术前无创分级鉴别工具。
研究设计与样本
- 回顾性研究,纳入157例手术切除且病理证实的无功能胰腺神经内分泌肿瘤患者,2012年11月至2019年12月行MRI扫描,从动脉期和门静脉期提取影像组学特征,采用LASSO法筛选特征,多变量逻辑回归分析rad-score与分级的关系。
诊断标准与关键数值
- rad-score由7个选定特征组成,每增加1分,G2/3风险增加35%;AUC为0.775;最大敏感度和特异度的最佳截断值为0.41;阈值概率高于0.3时,rad-score决策曲线获益优于全治或全不治方案。
临床应用与阅片要点
- 作者认为MRI rad-score可能作为无创工具用于无功能胰腺神经内分泌肿瘤的术前分级鉴别。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: We aimed to explore the relationship between the magnetic resonance imaging (MRI) radiomic score (rad-score) and the grades of non-functioning pancreatic neuroendocrine tumors (NF-pNETs) and evaluate the potential of the calculated MRI rad-score to differentiate grade 1 from grade 2/3 NF-pNETs.
METHODS: This retrospective study assessed 157 patients with surgically resected, pathologically confirmed NF-pNETs who underwent magnetic resonance scans from November 2012 to December 2019. Radiomic features were extracted from arterial and portal venous MRI. The least absolute shrinkage and selection operator method were used to select the features. Multivariate logistic regression models were used to analyze the association between the MRI rad-score and NF-pNET grades. The MRI rad-score performance was assessed based on its discriminative ability and clinical usefulness.
RESULTS: The MRI rad-score, which consisted of seven selected features, was significantly associated with the NF-pNET grades. Every 1-point increase in the rad-score was associated with a 35% increased risk of grade 2/3 disease. The score also showed high accuracy (area under the curve = 0.775). The best cut-off point for maximal sensitivity and specificity was at 0.41. In the decision curves, when the threshold probability was higher than 0.3, the rad-score used in this study to distinguish grades 1 and 2/3 NF-pNETs offered more benefits than the use of a treat-all-patients or a treat-none scheme.
CONCLUSIONS: The MRI rad-score showed a significant association with the grades of NF-pNETs. Thus, it may be used as a valuable non-invasive tool for differential NF-pNET grading.
引用
- Bian Y, Li J, Cao K, et al. Magnetic resonance imaging radiomic analysis can preoperatively predict G1 and G2/3 grades in patients with NF-pNETs. Abdom Radiol (NY). 2020. PMID: 32808056. doi:10.1007/s00261-020-02706-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。