肝移植术后评估:与1年移植物衰竭相关的影像学参数
回顾性分析202例成人肝移植术后3个月内CT,记录肝灌注缺损、实质均匀性及肝血管直径与衰减值,41例(20.3%)1年内移植物衰竭;肝灌注缺损和门静脉直径偏小独立预测1年移植物衰竭。
要点
- 肝移植术后3个月内CT出现肝灌注缺损者1年移植物衰竭风险增高(HR 5.43)。
- 右门静脉直径<11.5 mm、左门静脉直径<10.0 mm与移植物预后不良相关。
- 肝灌注缺损和门静脉直径偏小可独立预测1年移植物衰竭。
关键影像表现/征象
- 肝灌注缺损(LPD)在移植物衰竭组为18/25(67%),无衰竭组为15/98(15%),p<0.001。
- 肝实质低衰减在移植物衰竭组为20/41(48.8%),无衰竭组为17/161(10.6%),p<0.001。
- 右门静脉直径在移植物衰竭组为10.7±2.7 mm,无衰竭组为14.7±2.2 mm,p<0.001。
- 左门静脉直径在移植物衰竭组为9.8±3.0 mm,无衰竭组为12.4±2.2 mm,p<0.001。
诊断标准与关键数值
- 肝灌注缺损预测1年移植物衰竭的HR为5.43,p<0.001。
- 右门静脉直径偏小预测1年移植物衰竭的HR为3.33,p<0.001。
- 左门静脉直径偏小预测1年移植物衰竭的HR为3.13,p<0.05。
- 右门静脉<11.5 mm和左门静脉<10.0 mm与移植物预后不良相关。
- 所有测量观察者间一致性为fair至moderate(0.233~0.597)。
临床应用与阅片要点
- 肝移植术后3个月内CT阅片时应评估肝灌注缺损、肝实质低衰减及门静脉直径。
- 发现肝灌注缺损或门静脉直径偏小时,提示1年移植物衰竭风险增高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To identify post-liver transplant CT findings which predict graft failure within 1 year.
MATERIALS AND METHODS: We evaluated the CT scans of 202 adult liver transplants performed in our institution who underwent CT within 3 months after transplantation. We recorded CT findings of liver perfusion defect (LPD), parenchymal homogeneity, and the diameters and attenuations of the hepatic vessels. Findings were correlated to 1-year graft failure, and interobserver variability was assessed.
RESULTS: Forty-one (20.3%) of the 202 liver grafts failed within 1 year. Graft failure was highly associated with LPD (n = 18/25, or 67%, versus 15/98, or 15%, p < 0.001), parenchymal hypoattenuation (n = 20/41, or 48.8% versus 17/161, or 10.6%, p < 0.001), and smaller diameter of portal veins (right portal vein [RPV], 10.7 ± 2.7 mm versus 14.7 ± 2.2 mm, and left portal vein [LPV], 9.8 ± 3.0 mm versus 12.4 ± 2.2 mm, p < 0.001, respectively). Of these findings, LPD (hazard ratio [HR], 5.43, p < 0.001) and small portal vein diameters (HR, RPV, 3.33, p < 0.001, and LPV, 3.13, p < 0.05) independently predicted graft failure. All the measurements showed fair to moderate interobserver agreement (0.233~0.597).
CONCLUSION: For patients who have CT scan within the first 3 months of liver transplantation, findings of LPD and small portal vein diameters predict 1-year graft failure.
KEY POINTS: •Failed grafts are highly associated with liver perfusion defect, hypoattenuation, and small portal vein. •Right portal vein < 11.5 mm and left portal vein < 10.0 mm were associated with poor graft outcome. •Liver perfusion defect and small portal vein diameter independently predicted graft failure.
引用
- Chang WC, M Yeh B, Chu L, et al. Post-operative assessment in patients after liver transplantation: imaging parameters associated with 1-year graft failure. Eur Radiol. 2020. PMID: 32862291. doi:10.1007/s00330-020-07124-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。