文献速递腹部MR

通过MRI半自动测量肝表面结节度进行肝纤维化分期

Staging of Liver Fibrosis by Means of Semiautomatic Measurement of Liver Surface Nodularity in MRI.
PubMed 文献 · AJR Am J Roentgenol · 2020-07-01

本回顾性研究纳入132例在组织病理学检查前后6个月内接受钆塞酸二钠增强肝脏MRI的患者,开发半自动软件测量肝表面结节度(LSN)评分,并与Metavir纤维化评分对照。LSN评分与Metavir评分高度相关(ρ=0.713,p<0.001),区分F0-F1与F2-F4、F0-F2与F3-F4、F0-F3与F4的AUC分别为0.93、0.98和0.83。区分F0-F2与F3-F4的最佳截断值为0.850,敏感度100%、特异度85.4%。

要点

  • LSN评分与Metavir纤维化评分高度相关(ρ=0.713,p<0.001)。
  • LSN区分F0-F2与F3-F4的AUC为0.98,最佳截断值0.850,敏感度100%、特异度85.4%。
  • LSN区分F0-F1与F2-F4的AUC为0.93,区分F0-F3与F4的AUC为0.83。

诊断标准与关键数值

  • LSN评分区分Metavir F0-F1与F2-F4的AUC为0.93(95%CI 0.88-0.97,p<0.001)。
  • LSN评分区分Metavir F0-F2与F3-F4的AUC为0.98(95%CI 0.95-1.00,p<0.001),最佳截断值0.850,敏感度100%、特异度85.4%。
  • LSN评分区分Metavir F0-F3与F4的AUC为0.83(95%CI 0.76-0.90,p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purposes of this study were to evaluate the accuracy of a semiautomatic method of measuring liver surface nodularity (LSN) on contrast-enhanced MR images and to compare the LSN score with pathologic fibrosis stage. MATERIALS AND METHODS. This retrospective study included patients who had undergone gadoxetate disodium-enhanced liver MRI 6 months before or after histopathologic investigation including percutaneous parenchymal biopsy and surgical biopsy for staging of chronic liver disease between January 2010 and December 2018. Semiautomated LSN quantification software was developed to measure LSN at MRI. Aspartate aminotransferase to platelet ratio index and fibrosis-4 index were derived from serum laboratory test results. The reference standard for staging of liver fibrosis was Metavir score. The accuracy of LSN score for staging of liver fibrosis was evaluated with AUC, and the optimal cutoff value was calculated by Youden index. Spearman correlation coefficient was used for correlation analysis. RESULTS. The study included 132 patients (93 men, 39 women). LSN score was evaluated without technical failure. There was high correlation between LSN score and Metavir score (Spearman ρ = 0.713, p < 0.001). The AUCs of LSN score for distinguishing Metavir score were 0.93 for F0-F1 versus F2-F4 (95% CI, 0.88-0.97; p < 0.001), 0.98 for F0-F2 vs F3-F4 (95% CI, 0.95-1.00; p < 0.001), and 0.83 for F0-F3 versus F4 (95% CI, 0.76-0.90; p < 0.001). The optimal cutoff value for differentiating F0-F2 from F3-F4 was 0.850 with 100% sensitivity and 85.4% specificity. CONCLUSION. LSN score calculated semiautomatically from MR images of the liver has high accuracy and correlates directly with the pathologic fibrosis stage.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Kim SW, Kim YR, Choi KH, et al. Staging of Liver Fibrosis by Means of Semiautomatic Measurement of Liver Surface Nodularity in MRI. AJR Am J Roentgenol. 2020. PMID: 32755157. doi:10.2214/AJR.19.22041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。