肝纤维化与炎症的磁共振成像分析:大量灰色地带限制临床应用
该综述总结常规非增强多b值扩散加权成像、可变翻转角T1弛豫图和STIR图像等MR成像参数对肝纤维化和炎症的诊断效能,指出虽然部分参数与组织学评分显著相关,但效应量小且各级别间重叠广泛,精度和可重复性低限制其临床价值;MR弹性成像仍是检测进展期纤维化唯一高诊断准确度的影像方法,炎症领域仍无法替代活检。
要点
- MR弹性成像仍是检测进展期纤维化唯一高诊断准确度的影像方法。
- 常规MR成像参数与组织学评分虽显著相关,但效应量小且严重程度分级间重叠广泛。
- MR成像对排除进展期纤维化无适用性,对确认进展期纤维化准确度低。
关键影像表现/征象
- 部分MR成像衍生参数与组织学评分显示显著相关,但效应量小且严重程度分级间重叠广泛是普遍规律。
- 与脂肪和铁定量相反,MR成像指标精度和可重复性低,限制其在纤维化和炎症评估中的临床相关性。
临床应用与阅片要点
- 在序贯临床方法中联合不同方法时,MR成像对排除进展期纤维化无适用性,对确认进展期纤维化准确度低。
- MR弹性成像仍是检测进展期纤维化唯一高诊断准确度的影像方法。
- 炎症评估仍处于灰色地带,活检无法被替代,需进一步研究。
局限性
- 部分MR成像衍生参数虽与组织学评分显著相关,但效应量小且严重程度分级间重叠广泛。
- MR成像指标精度和可重复性低。
- 炎症领域仍需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Magnetic resonance (MR) identification and grading of subjects with liver fibrosis and inflammation represents a clinical challenge. MR elastography plays a well-defined role in fibrosis estimation, but its use is not widely available in clinical settings. Given that liver MR is becoming the reference standard for fat and iron quantitation, there is a need to clarify whether there is any role for MR imaging in the concomitant evaluation of fibrosis and inflammation in this setting. This review summarizes the diagnostic estimations of different MR imaging parameters obtained from conventional non-contrast-enhanced multiple b values diffusion-weighted acquisitions, variable flip angles T1 relaxation maps and STIR images. Although some derived parameters have shown a significant correlation to histological scores, a small magnitude of effect with wide overlap across severity grades is the rule. Contrary to fat and iron quantification, the low precision and reproducibility of MR imaging metrics limits its clinical relevance in fibrosis and inflammation assessment. In a sequential clinical approach combining different methodologies, MR imaging has no applicability for ruling-out and low accuracy for ruling-in advanced fibrosis. Thereby, MR elastography remains as the only image method with high diagnostic accuracy for the detection of advanced fibrosis. Until date, inflammation remains in a gray zone where biopsy cannot be replaced, and further investigations are needed. The present review offers an in-depth discuss of the MR imaging diagnostic performance for the evaluation of liver fibrosis and inflammation, highlighting the need for scientific improvements.
引用
- Marti-Aguado D, Rodríguez-Ortega A, Alberich-Bayarri A, et al. Magnetic Resonance imaging analysis of liver fibrosis and inflammation: overwhelming gray zones restrict clinical use. Abdom Radiol (NY). 2020. PMID: 32857259. doi:10.1007/s00261-020-02713-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。