文献速递腹部US

点剪切波与二维剪切波弹性成像对慢性丙型肝炎患者肝纤维化无创评估的诊断性能比较:以瞬时弹性成像为参考

Comparative Study Between the Diagnostic Performance of Point and 2-D Shear-Wave Elastography for the Non-invasive Assessment of Liver Fibrosis in Patients With Chronic Hepatitis C Using Transient Elastography as Reference.
PubMed 文献 · Ultrasound Med Biol · 2020-08-14

本研究以瞬时弹性成像(TE)为参考,比较弹性成像点定量(ElastPQ)与GE二维剪切波弹性成像(2-D-SWE.GE)在慢性HCV感染患者中无创评估肝纤维化的诊断性能。三种方法可行性率无显著差异(p=0.507),两种弹性成像所测肝硬度值良好相关(r=0.78),ElastPQ所测平均肝硬度值显著高于2-D-SWE.GE(12.1±7.3 kPa vs. 10.4±4.0 kPa,p<0.0001);2-D-SWE.GE与ElastPQ在F≥2、F≥3、F=4纤维化分期的诊断性能上无显著差异(p分别为0.89、0.76、0.86)。

要点

  • ElastPQ所测肝硬度值显著高于2-D-SWE.GE(12.1±7.3 kPa vs. 10.4±4.0 kPa,p<0.0001),报告时需注明所用技术。
  • 两种剪切波弹性成像在F≥2、F≥3、F=4纤维化分期的诊断性能无显著差异(p分别为0.89、0.76、0.86)。
  • TE、ElastPQ与2-D-SWE.GE的可行性率无显著差异(p=0.507),两种剪切波方法肝硬度值良好相关(r=0.78)。

诊断标准与关键数值

  • 以TE为参考,2-D-SWE.GE与ElastPQ在F≥2纤维化分期的诊断性能无显著差异(p=0.89)。
  • 以TE为参考,2-D-SWE.GE与ElastPQ在F≥3纤维化分期的诊断性能无显著差异(p=0.76)。
  • 以TE为参考,2-D-SWE.GE与ElastPQ在F=4纤维化分期的诊断性能无显著差异(p=0.86)。
  • ElastPQ所测平均肝硬度值为12.1±7.3 kPa,2-D-SWE.GE为10.4±4.0 kPa,ElastPQ显著高于2-D-SWE.GE(p<0.0001)。
  • 两种弹性成像所测肝硬度值良好相关(r=0.78)。

临床应用与阅片要点

  • 报告肝硬度值时需注明所用剪切波弹性成像技术(ElastPQ或2-D-SWE.GE),因两者测值存在显著差异。
  • TE、ElastPQ与2-D-SWE.GE的可行性率无显著差异(p=0.507),提示三种方法均可用于肝硬度评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The study compared the diagnostic performance of two shear-wave elastography techniques, elastography point quantification (ElastPQ) and 2-D shear-wave elastography by General Electric (2-D-SWE.GE), for the non-invasive assessment of liver fibrosis in a cohort of patients with chronic hepatitis C virus (HCV) infection, using transient elastography (TE) as the reference method. There was no significant difference between the feasibility rates of TE, ElastPQ and 2-D-SWE.GE (p = 0.507). A good correlation was found between the liver stiffness (LS) values obtained using the two elastographic methods (r = 0.78). The mean LS values obtained using the ElastPQ technique were significantly higher than those obtained using 2-D-SWE.GE (12.1 ± 7.3 kPa vs. 10.4 ± 4.0 kPa, p < 0.0001). Pairwise comparisons of receiver operator characteristics curves between 2-D-SWE.GE and ElastPQ have shown that there are no significant differences in their performance for staging F ≥ 2 fibrosis (p = 0.89), F ≥ 3 fibrosis (p = 0.76) and F = 4 fibrosis (p = 0.86) in patients with chronic HCV infection.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Bâldea V, Sporea I, Lupușoru R, et al. Comparative Study Between the Diagnostic Performance of Point and 2-D Shear-Wave Elastography for the Non-invasive Assessment of Liver Fibrosis in Patients With Chronic Hepatitis C Using Transient Elastography as Reference. Ultrasound Med Biol. 2020. PMID: 32807571. doi:10.1016/j.ultrasmedbio.2020.07.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。