基于压缩感知的梯度回波灌注序列SPARSE与常规梯度回波序列在评估心肌缺血中的可比性
研究纳入23例因负荷灌注心脏磁共振异常而转诊冠状动脉造影的患者,在6周内分别用常规TurboFLASH和原型SPARSE序列行腺苷负荷灌注心脏磁共振,并以冠状动脉造影(FFR<0.75或目测狭窄>90%)为金标准。SPARSE序列信噪比和对比噪声比高于TurboFLASH,暗环伪影更少(9% vs 23%),视觉评估假阳性灌注缺损更少(1个 vs 3个),定量灌注分析检测灌注缺损的能力两者相当(差异均未达统计学显著)。结论认为SPARSE序列可可靠检测心肌缺血。
要点
- SPARSE序列对比噪声比52.1±27.4高于TurboFLASH的40.5±17.6(p<0.01),信噪比15.6±6.2高于13.2±4.2(p<0.01)。
- 暗环伪影SPARSE占9%的节段,少于TurboFLASH的23%。
- 视觉评估SPARSE检出假阳性灌注缺损1个,少于TurboFLASH的3个。
核心结论
- 基于压缩感知的SPARSE序列可可靠检测心肌缺血。
研究设计与样本
- 研究纳入23例因负荷灌注心脏磁共振异常而转诊冠状动脉造影的患者,平均年龄69.6±8.9岁,46%为女性。
- 所有患者在6周内接受两次腺苷负荷心脏磁共振,分别使用常规TurboFLASH序列和原型SPARSE序列,并接受定量冠状动脉造影及血流储备分数(FFR)检查。
- 以冠状动脉造影为金标准,FFR<0.75或目测狭窄>90%定义为心肌缺血。
- 灌注成像诊断性能在基底段、中间段和心尖段切片上评估,采用信号上升斜率法和基于费米函数模型的反卷积技术定量心肌灌注储备(MPR)。
关键影像表现/征象
- 常规TurboFLASH序列与SPARSE序列的图像质量相似(2.9±0.5 vs 3.1±0.7,p=0.06)。
- SPARSE序列对比噪声比高于TurboFLASH序列(52.1±27.4 vs 40.5±17.6,p<0.01)。
- SPARSE序列信噪比高于TurboFLASH序列(15.6±6.2 vs 13.2±4.2,p<0.01)。
- 暗环伪影在SPARSE序列中占9%的节段,少于TurboFLASH序列的23%。
- 视觉评估中,SPARSE序列检出假阳性灌注缺损1个,少于TurboFLASH序列的3个。
诊断标准与关键数值
- 以冠状动脉造影为金标准,FFR<0.75或目测狭窄>90%定义为心肌缺血。
- 基于节段的定量灌注分析显示,TurboFLASH与SPARSE对灌注缺损的检测能力相当:上升斜率法MPR为TurboFLASH 0.88±0.18 vs SPARSE 0.77±0.26(p=0.06);费米函数模型为TurboFLASH 0.85±0.24 vs SPARSE 0.76±0.30(p=0.13)。
临床应用与阅片要点
- SPARSE序列图像质量与常规TurboFLASH相似,且对比噪声比和信噪比更高、暗环伪影更少,可用于负荷灌注心脏磁共振评估心肌缺血。
- 视觉评估时SPARSE序列假阳性灌注缺损少于TurboFLASH序列。
- 定量MPR分析中,两种序列检测灌注缺损的能力相当(差异均未达统计学显著)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Stress perfusion imaging plays a major role in non-invasive detection of coronary artery disease. We compared a compressed sensing-based and a conventional gradient echo perfusion sequence with regard to image quality and diagnostic performance.
METHOD: Patients sent for coronary angiography due to pathologic stress perfusion CMR were recruited. All patients underwent two adenosine stress CMR using conventional TurboFLASH and prototype SPARSE sequence as well as quantitative coronary angiography with fractional flow reserve (FFR) within 6 weeks. Coronary angiography was considered gold standard with FFR < 0.75 or visual stenosis >90 % for identification of myocardial ischemia. Diagnostic performance of perfusion imaging was assessed in basal, mid-ventricular and apical slices by quantification of myocardial perfusion reserve (MPR) analysis utilizing the signal upslope method and a deconvolution technique using the fermi function model.
RESULTS: 23 patients with mean age of 69.6 ± 8.9 years were enrolled. 46 % were female. Image quality was similar in conventional TurboFLASH sequence and SPARSE sequence (2.9 ± 0.5 vs 3.1 ± 0.7, p = 0,06). SPARSE sequence showed higher contrast-to-noise ratio (52.1 ± 27.4 vs 40.5 ± 17.6, p < 0.01) and signal-to-noise ratio (15.6 ± 6.2 vs 13.2 ± 4.2, p < 0.01) than TurboFLASH sequence. Dark-rim artifacts occurred less often with SPARSE (9 % of segments) than with TurboFLASH (23 %). In visual assessment of perfusion defects, SPARSE sequence detected less false-positive perfusion defects (n = 1) than TurboFLASH sequence (n = 3). Quantitative perfusion analysis on segment basis showed equal detection of perfusion defects for TurboFLASH and SPARSE with both upslope MPR analysis (TurboFLASH 0.88 ± 0.18; SPARSE 0.77 ± 0.26; p = 0.06) and fermi function model (TurboFLASH 0.85 ± 0.24; SPARSE 0.76 ± 0.30; p = 0.13).
CONCLUSIONS: Compressed sensing perfusion imaging using SPARSE sequence allows reliable detection of myocardial ischemia.
引用
- Muehlberg F, Stoetzner A, Forman C, et al. Comparability of compressed sensing-based gradient echo perfusion sequence SPARSE and conventional gradient echo sequence in assessment of myocardial ischemia. Eur J Radiol. 2020. PMID: 32846332. doi:10.1016/j.ejrad.2020.109213
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。