文献速递心血管CT

动态CT心肌灌注成像定量、半定量与视觉分析的诊断效能:以有创血流储备分数为参考的验证研究

Diagnostic performance of quantitative, semi-quantitative, and visual analysis of dynamic CT myocardial perfusion imaging: a validation study with invasive fractional flow reserve.
PubMed 文献 · Eur Radiol · 2020-08-14

前瞻性纳入62例胸痛、中度至高度梗阻性冠心病验前概率患者,均在4周内行动态CT心肌灌注成像和有创血流储备分数(FFR)测量,比较绝对心肌血流量(MBF)、MBF比值及视觉分析的诊断效能。以FFR为参考,MBF与MBF比值的AUC相似(0.942对0.956,p=0.413),均高于视觉分析(AUC=0.802,均p<0.01);血管水平MBF的敏感度、特异度和诊断准确率分别为84.3%、97.7%和90.5%,MBF比值分别为96.1%、93.2%和94.7%。

要点

  • 以FFR为参考,绝对MBF与MBF比值诊断血流动力学显著狭窄的AUC分别为0.942和0.956,两者相似(p=0.413)。
  • MBF与MBF比值的AUC均高于视觉分析(AUC=0.802,均p<0.01)。
  • 血管水平MBF比值敏感度96.1%、特异度93.2%、准确率94.7%,MBF分别为84.3%、97.7%、90.5%。

核心结论

  • 以FFR为参考,绝对MBF与MBF比值具有相似且优秀的诊断效能,且两者均优于视觉分析对心肌缺血的检测。

研究设计与样本

  • 前瞻性连续纳入胸痛且梗阻性冠心病验前概率中度至高度的患者,最终分析62例患者共95支目标血管。
  • 所有患者在4周内接受动态CT心肌灌注成像和有创FFR测量,以FFR为参考标准。
  • 动态CT心肌灌注成像的平均辐射剂量为3.0(2.2-4.0)mSv。

关键影像表现/征象

  • 病变水平缺血节段的平均绝对MBF显著低于非缺血节段,为78.0(65.0-86.0)mL/min/100 mL对133.0(117.5-163.8)mL/min/100 mL(p<0.001)。
  • FFR阳性区域的病变水平MBF比值显著低于FFR阴性区域,为0.52(0.44-0.64)对0.93(0.91-0.97)(p<0.001)。

诊断标准与关键数值

  • 基于病变的ROC曲线分析显示,MBF与MBF比值检测血流动力学显著病变的AUC分别为0.942和0.956(p=0.413),均大于视觉分析的AUC=0.802(均p<0.01)。
  • 血管水平以FFR为参考,绝对MBF的敏感度84.3%、特异度97.7%、诊断准确率90.5%;MBF比值的敏感度96.1%、特异度93.2%、诊断准确率94.7%。

临床应用与阅片要点

  • 绝对MBF与MBF比值均可用于动态CT心肌灌注成像定量评估心肌缺血,两者诊断效能相似。
  • 定量参数MBF和MBF比值对血流动力学显著狭窄的检测效能优于视觉分析。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the diagnostic performance of absolute myocardial blood flow (MBF), MBFratio, and visual analysis of dynamic CT myocardial perfusion imaging (CT-MPI) for the detection of hemodynamically significant coronary stenosis.

METHODS: Consecutive patients with chest pain and intermediate-to-high pre-test probability of obstructive coronary artery disease were prospectively enrolled. All patients were referred for dynamic CT-MPI and fractional flow reserve (FFR) measurements within 4 weeks. Absolute MBF, MBFratio (mean MBF of stenosis-subtended territories versus that of reference territories), and visually identified perfusion defect were tested for the diagnostic performance with reference to FFR.

RESULTS: Sixty-two patients with 95 target vessels were included for final analysis. The mean radiation dose for dynamic CT-MPI was 3.0 (2.2-4.0) mSv. The mean lesion-based absolute MBF value was significantly lower in ischemic segments than that in non-ischemic segments (78.0 (65.0-86.0) mL/min/100 mL vs. 133.0 (117.5-163.8) mL/min/100 mL, p < 0.001). Similarly, the lesion-based MBFratio was also markedly lower in territories with positive FFR results (0.52 (0.44-0.64) vs. 0.93 (0.91-0.97), p < 0.001). According to per-lesion ROC curve analysis, MBF and MBFratio had a similar area under the curve (AUC) for detecting hemodynamically significant lesions (AUC = 0.942 vs. 0.956, p = 0.413), which were larger than that of visual analysis (AUC = 0.802, both p < 0.01). The vessel-based sensitivity, specificity, and diagnostic accuracy were 84.3%, 97.7%, and 90.5% for MBF and 96.1%, 93.2%, and 94.7% for MBFratio.

CONCLUSIONS: Absolute MBF and MBFratio had similarly excellent diagnostic performance with reference to FFR. In addition, these two parameters outperformed visual analysis for the detection of myocardial ischemia.

KEY POINTS: • The mean MBF and MBFratio were significantly lower in ischemic segments than those in non-ischemic segments. • Absolute MBF and MBFratio had similar AUCs for the detection of hemodynamically significant lesions (AUC = 0.942 vs. 0.956, p = 0.413), which were larger than that of visual analysis (AUC = 0.802, both p < 0.01). • The vessel-based sensitivity, specificity, and diagnostic accuracy were 84.3%, 97.7%, and 90.5% for absolute MBF and 96.1%, 93.2%, and 94.7% for MBFratio.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Li Y, Dai X, Lu Z, et al. Diagnostic performance of quantitative, semi-quantitative, and visual analysis of dynamic CT myocardial perfusion imaging: a validation study with invasive fractional flow reserve. Eur Radiol. 2020. PMID: 32794126. doi:10.1007/s00330-020-07145-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。