冠状动脉CT血管造影评估支架:碘帕醇-370与碘佛醇-320低渗碘对比剂的比较
这项前瞻性双盲非劣效随机试验将65例低危稳定型心绞痛支架随访患者分入碘帕醇-370组(33例)或碘佛醇-320组(32例),行冠状动脉CTA评估支架管腔图像质量。两组支架管腔图像质量无显著差异(Likert评分4.48±0.75 vs 4.54±0.65,p=0.5),但碘佛醇-320组在自体冠状动脉节段(包括远端节段)的管腔平均衰减值较低。支架图像质量主要受支架直径、心率变异和管腔衰减增加率影响。
要点
- 碘帕醇-370与碘佛醇-320在支架管腔图像质量上无显著差异(Likert评分4.48±0.75 vs 4.54±0.65,p=0.5)。
- 碘佛醇-320组在自体冠状动脉节段(含远端节段)的管腔平均衰减值显著低于碘帕醇-370组。
- 支架图像质量与支架直径、心率变异及管腔衰减增加率相关。
关键影像表现/征象
- 支架管腔图像质量采用5分Likert量表评估,碘帕醇-370组为4.48±0.75,碘佛醇-320组为4.54±0.65,两组无显著差异(p=0.5)。
- 管腔衰减增加率在碘帕醇-370组为0.39±0.42 HU,碘佛醇-320组为0.48±0.44 HU,两组相似(p=0.08)。
- 自体冠状动脉节段(支架前、支架后、远端节段及冠状动脉斑块)管腔平均衰减值存在显著差异,碘佛醇-320组数值较低,包括远端节段对比剂平均衰减值。
诊断标准与关键数值
- 支架管腔图像质量采用5分Likert量表分级。
- 管腔衰减增加率按所有支架计算。
临床应用与阅片要点
- 冠状动脉CTA可实现支架的充分可视化。
- 支架图像质量受支架直径、心率变异和管腔衰减增加率影响。
- 更高浓度对比剂可能提供更好的整体可视化,尤其是冠状动脉远端节段。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Qualitative and quantitative image analysis between Iopamidol-370 and Ioversol-320 in stents´ evaluation by coronary computed tomography angiography (CTA).
METHODS: Sixty-five patients with low-risk stable angina undergoing stent follow-up with coronary CTA were assigned to Iopamidol I-370 (n = 33) or Ioversol I-320 (n = 32) in this prospective, double-blind, non-inferiority, randomized trial. Stent lumen image quality was graded by 5-point Likert Scale. Lumen mean attenuation was measured at native coronary segments: pre-stent, post-stent, distal segments and at coronary plaques. Lumen attenuation increase (LAI) ratio was calculated for all stents. Heart rate (HR) variation, premature heart beats (PHB), heat sensation (HS), blooming and beam hardening were also assessed.
RESULTS: Image quality was similar between groups, with no significant difference (Likert score 4.48 ± 0.75 vs 4.54 ± 0.65, p = 0.5). There were similarities in LAI ratio between I-370 and I-320 (0.39 ± 0.42 vs 0.48 ± 0.44 HU, p = 0.08). Regarding lumen mean attenuation at native coronary segments, a significant difference was observed, with I-320 presenting lower values, including contrast mean attenuation in distal segments. After statistical multivariate analysis, three variables correlated with stent image quality: 1) stent diameter, 2) HR variation and 3) stent lumen LAI ratio.
CONCLUSIONS: There was no significant difference between Iopamidol-370 mgI ml-1 and Ioversol-320 mgI ml-1 contrasts regarding overall stent lumen image quality, which was mainly influenced by stent diameter, HR and LAI ratio.Advances in knowledge:Coronary CTA allows adequate stents' visualization and image quality is influenced by stent diameter, HR variation and LAI ratio.Stents' image quality showed no difference between different concentration contrasts (I-370 vs. I-320); however, higher concentration contrasts may provide an improved overall visualization, especially regarding coronary distal segments.