健康受试者运动期间心血管四维流MRI的可行性
这项前瞻性研究在11名健康年轻成人中,于静息和踏车运动时进行心脏四维流MRI,测量升主动脉和主肺动脉血流及左右心室动能。9人完成静息与运动成像;运动时升主动脉和主肺动脉血流较静息增加且重复性高,但动能重复性差,需进一步改进分割方法。
要点
- 四维流MRI可在剧烈运动时定量升主动脉和主肺动脉血流,且重复性高。
- 运动时升主动脉和主肺动脉血流较静息增加。
- 动能测量重复性差,主要因分割方法不理想,尚需改进。
关键影像表现/征象
- 体循环和肺循环内部血流一致性分析显示,静息时平均相对差异为10%,运动时为16%。
- 升主动脉和主肺动脉血流测量的观察者间相对差异在任何血管均未超过6%,即使在运动时也显示极好相关性。
- 动能测量的相对差异增大,典型约为30%,观察者间相关性差。
诊断标准与关键数值
- 升主动脉和主肺动脉血流测量的观察者间相对差异在任何血管均未超过6%,即使在运动时也显示极好相关性。
- 体循环和肺循环内部血流一致性分析显示,静息时平均相对差异为10%,运动时为16%。
- 动能测量的相对差异增大,典型约为30%,观察者间相关性差。
临床应用与阅片要点
- 四维流MRI可用于在剧烈运动时定量升主动脉和主肺动脉血流,且重复性高。
- 动能测量因分割方法不理想而重复性降低,需进一步开发后方可用于临床。
局限性
- 动能因分割方法不理想而重复性降低,需进一步开发后方可用于临床。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the feasibility of using four-dimensional (4D) flow MRI to quantify blood flow and kinetic energy (KE) in the heart during strenuous exercise.
MATERIALS AND METHODS: For this prospective study, cardiac 4D flow MRI was performed in 11 healthy young adult participants (eight men, three women; mean age, 26 years ± 1 [standard deviation]) at rest and during exercise with an MRI-compatible exercise stepper between March 2016 and July 2017. Flow was measured in the ascending aorta (AAo) and main pulmonary artery (MPA). KE was quantified in the left and right ventricle. Significant changes in flow and KE during exercise were identified by using t tests. Repeatability was assessed with inter- and intraobserver comparisons and an analysis of internal flow consistency.
RESULTS: Nine participants successfully completed both rest and exercise imaging. Internal flow consistency analysis in systemic and pulmonary circulation showed average relative differences of 10% at rest and 16% during exercise. For flow measurements in the AAo and MPA, relative differences between observers never exceeded 6% in any vessel and showed excellent correlation, even during exercise. Relative differences were increased for KE, typically on the order of 30%, with poor interobserver correlation between measurements.
CONCLUSION: Four-dimensional flow MRI can quantify increases in flow in the AAo and MPA during strenuous exercise and is highly repeatable. KE had reduced repeatability because of suboptimal segmentation methods and requires further development before clinical implementation. Supplemental material is available for this article. © RSNA, 2020See also the commentary by Markl and Lee in this issue.
引用
- Macdonald JA, Beshish AG, Corrado PA, et al. Feasibility of Cardiovascular Four-dimensional Flow MRI during Exercise in Healthy Participants. Radiol Cardiothorac Imaging. 2020. PMID: 32734274. doi:10.1148/ryct.2020190033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。