文献速递心血管CT

收缩期高螺距冠状动脉CT血管成像用于评估心脏移植受者的冠状动脉

Systolic High-Pitch Coronary CT Angiography for Evaluation of the Coronary Arteries in Heart Transplant Recipients.
PubMed 文献 · AJR Am J Roentgenol · 2020-08-12

本研究评估了22例原位心脏移植受者采用第三代双源CT高螺距模式行收缩期单心跳冠状动脉CT血管成像的可行性、图像质量和辐射剂量。322个冠状动脉节段中97.5%达到诊断质量,观察者间一致性很好,高螺距模式与回顾性心电门控图像质量无显著差异,但辐射剂量显著降低(中位剂量长度乘积31.6 vs 736.5 mGy×cm,p<0.001)。

要点

  • 收缩期30% R-R间期触发的高螺距CCTA在心脏移植受者中97.5%的冠状动脉节段达到诊断质量。
  • 图像质量与回顾性心电门控无显著差异,但辐射剂量显著更低(31.6 vs 736.5 mGy×cm)。
  • 观察者间一致性很好(每患者κ=0.82,每血管κ=0.83,每节段κ=0.89)。

核心结论

  • 在心脏移植受者中,于收缩期行单心跳高螺距CCTA可获得诊断质量的冠状动脉图像,且辐射剂量很低。

研究设计与样本

  • 研究纳入22例连续的原位心脏移植受者(16男6女,中位年龄66.5岁,中位心率91次/分),采用第三代双源CT高螺距模式行CCTA以排除冠状动脉移植物血管病,数据采集触发于R-R间期30%处;由两名独立观察者盲法按4分法评估图像质量(4分优秀,1分不可评估,2-4分表示诊断质量),并与既往回顾性心电门控检查对比(如有),用kappa统计评估观察者间一致性。

关键影像表现/征象

  • 共评估322个冠状动脉节段,97.5%的节段达到诊断图像质量。
  • 每患者中位图像质量评分为4.0(3.0-4.0),针对整个冠状动脉树。
  • 高螺距与回顾性心电门控CCTA的图像质量评分无显著差异。

诊断标准与关键数值

  • 图像质量采用4分法评估:4分优秀,1分不可评估,2-4分表示诊断质量。
  • 观察者间一致性:每患者κ=0.82,每血管κ=0.83,每节段κ=0.89。
  • 高螺距模式中位剂量长度乘积31.6 mGy×cm(四分位距23.1-38.8)vs 回顾性心电门控736.5 mGy×cm(四分位距655.5-845.7),p<0.001。

临床应用与阅片要点

  • 在心脏移植受者中采用收缩期30% R-R间期触发的高螺距单心跳CCTA,可获得诊断质量的冠状动脉图像并显著降低辐射剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to evaluate the feasibility, image quality, and radiation dose of high-pitch coronary CT angiography (CCTA) in orthotopic heart transplant (OHT) recipients. SUBJECTS AND METHODS. Twenty-two consecutive OHT recipients (16 men, six women; median age, 66.5 years [interquartile range, 51.3-70.3 years]; median heart rate, 91 beats/min [interquartile range, 79.3-97.3 beats/min]) underwent CCTA with a third-generation dual-source CT scanner in high-pitch mode to rule out coronary allograft vasculopathy. Data acquisition was triggered at 30% of the R-R interval. Two independent observers blindly assessed image quality on a per-segment, per-vessel, and per-patient basis using a 4-point scale (4, excellent; 1, not evaluative). Scores 2-4 indicated diagnostic quality. Studies were compared with previously performed retrospective ECG-gated examinations, when available. Interobserver agreement on the image quality was assessed with kappa statistics. Radiation dose was recorded. RESULTS. A total of 322 coronary segments were evaluated. Diagnostic image quality was observed in 97.5% of the segments. Interobserver agreement for image quality assessment was very good on a per-patient (κ = 0.82), per-vessel (κ = 0.83), and per-segment basis (κ = 0.89). The median per-patient image quality score was 4.0 (3.0-4.0) for the entire coronary tree. A comparison of image quality scores between high-pitch and retrospective ECG-gated CCTA examinations showed no significant differences, but the estimated mean radiation dose was significantly lower for the high-pitch mode (median dose-length product, 31.6 mGy × cm [interquartile range, 23.1-38.8 mGy × cm] vs 736.5 mGy × cm [interquartile range, 655.5-845.7 mGy × cm], p < 0.001). CONCLUSION. Performing single-heartbeat high-pitch CCTA during the systolic phase of the cardiac cycle in OHT recipients results in diagnostic image quality in coronary angiograms at very low radiation dose.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Bastarrika G, Calvo M, Ezponda A, et al. Systolic High-Pitch Coronary CT Angiography for Evaluation of the Coronary Arteries in Heart Transplant Recipients. AJR Am J Roentgenol. 2020. PMID: 32783558. doi:10.2214/AJR.19.22639

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。