无阻塞性冠状动脉疾病患者的动态CT心肌灌注成像:应激后不同心率增量下心肌血流量定量
回顾性纳入204例同时行动态CT心肌灌注成像与冠状动脉CT血管造影、并排除阻塞性冠状动脉疾病等的人群,用混合去卷积与最大斜率模型测量应激时整体心肌血流量。整体心肌血流量中位数为156.4 mL/100 mL/min,心率增量10–19 bpm者低于20–29 bpm者(153.3 vs. 171.3 mL/100 mL/min,p=0.027),增量≥30 bpm时差异不显著。
要点
- 动态CT-MPI加CCTA的中位辐射剂量为5.5(4.5–6.8)mSv。
- 全部受试者整体心肌血流量中位数为156.4(139.8–180.4)mL/100 mL/min。
- 心率增量10–19 bpm者整体心肌血流量低于20–29 bpm者(153.3 vs. 171.3 mL/100 mL/min,p=0.027)。
关键影像表现/征象
- 采用混合去卷积与最大斜率模型测量应激时整体心肌血流量。
- 记录应激后心率增量,并按增量10–19 bpm、20–29 bpm及≥30 bpm分组比较整体心肌血流量。
诊断标准与关键数值
- 全部受试者整体心肌血流量中位数为156.4(139.8–180.4)mL/100 mL/min。
- 心率增量10–19 bpm者整体心肌血流量为153.3 mL/100 mL/min,低于20–29 bpm者的171.3 mL/100 mL/min(p=0.027)。
- 心率增量进一步增至≥30 bpm时,上述差异不再显著。
临床应用与阅片要点
- 动态CT-MPI加CCTA的中位辐射剂量为5.5(4.5–6.8)mSv。
- 解读整体心肌血流量时需结合应激后心率增量,心率增量≥20 bpm者整体心肌血流量更高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The present study aimed to investigate the association between myocardial blood flow (MBF) quantified by dynamic CT myocardial perfusion imaging (CT-MPI) and the increments in heart rate (HR) after stress in patients without obstructive coronary artery disease.
MATERIALS AND METHODS: We retrospectively included 204 subjects who underwent both dynamic CT-MPI and coronary CT angiography (CCTA). Patients with more than minimal coronary stenosis (diameter ≥ 25%), history of myocardial infarction/revascularization, cardiomyopathy, and microvascular dysfunction were excluded. Global MBF at stress was measured using hybrid deconvolution and maximum slope model. Furthermore, the HR increments after stress were recorded.
RESULTS: The median radiation dose of dynamic CT-MPI plus CCTA was 5.5 (4.5-6.8) mSv. The median global MBF of all subjects was 156.4 (139.8-180.4) mL/100 mL/min. In subjects with HR increment between 10 to 19 beats per minute (bpm), the global MBF was significantly lower than that of subjects with increment between 20 to 29 bpm (153.3 mL/100 mL/min vs. 171.3 mL/100 mL/min, p = 0.027). This difference became insignificant when the HR increment further increased to ≥ 30 bpm.
CONCLUSION: The global MBF value was associated with the extent of increase in HR after stress. Significantly higher global MBF was seen in subjects with HR increment of ≥ 20 bpm.
引用
- Yu L, Tao X, Dai X, et al. Dynamic CT Myocardial Perfusion Imaging in Patients without Obstructive Coronary Artery Disease: Quantification of Myocardial Blood Flow according to Varied Heart Rate Increments after Stress. Korean J Radiol. 2020. PMID: 32783416. doi:10.3348/kjr.2020.0249
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。