文献速递神经外周血管介入CTMRDSA

神经介入中主动脉弓上血管置管的融合影像引导:可行性研究

Fusion Image Guidance for Supra-Aortic Vessel Catheterization in Neurointerventions: A Feasibility Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-08-20

本研究评估了实时透视与MR血管成像或CT血管成像融合引导主动脉弓上血管置管的可行性,共25例患者行MRA、8例患者行CTA,在35次置管操作中对151条弓上血管进行靶向引导。分割与图像配准平均耗时7±2分钟,融合虚拟路径图在84.8%(128/151)的评估标志点上被认为准确,靠近主动脉弓的血管组准确率更高(92.4%;OR 4.88;95%CI 1.83-11.66;P=0.003)。作者认为该技术可行,但需进一步改进以提高颈部水平的准确性,并需进一步研究评估手术时间节省和减少X线辐射暴露。

要点

  • 实时透视与MRA/CTA融合引导主动脉弓上血管置管在84.8%(128/151)的标志点上准确。
  • 靠近主动脉弓的血管融合路径图准确率更高(92.4%;OR 4.88;95%CI 1.83-11.66;P=0.003)。
  • 分割与图像配准平均耗时7±2分钟。

诊断标准与关键数值

  • 融合引导可行性通过记录介入神经放射科医生在透视和常规路径图(独立于融合引导)下按标准技术执行的置管来评估。
  • 融合路径图精度通过半定量3点量表测量导丝/导管位置与虚拟CTA/MRA图像上血管之间的最大偏移来评估。
  • 融合虚拟路径图在84.8%(128/151)的评估标志点上被认为准确。
  • 靠近主动脉弓的血管组准确率为92.4%(OR 4.88;95%CI 1.83-11.66;P=0.003)。

临床应用与阅片要点

  • 作者认为透视与MRA/CTA融合引导主动脉弓上血管介入是可行的。
  • 作者指出需进一步改进该技术以提高颈部水平的准确性。
  • 作者指出需进一步研究评估手术时间节省和减少X线辐射暴露。

局限性

  • 作者指出需进一步改进技术以提高颈部水平的准确性。
  • 作者指出需进一步研究评估手术时间节省和减少X线辐射暴露。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Endovascular navigation through tortuous vessels can be complex. Tools that can optimise this access phase need to be developed. Our aim was to evaluate the feasibility of supra-aortic vessel catheterization guidance by means of live fluoroscopy fusion with MR angiography or CT angiography.

MATERIALS AND METHODS: Twenty-five patients underwent preinterventional diagnostic MRA, and 8 patients underwent CTA. Fusion guidance was evaluated in 35 sessions of catheterization, targeting a total of 151 supra-aortic vessels. The time for MRA/CTA segmentation and fluoroscopy with MRA/CTA coregistration was recorded. The feasibility of fusion guidance was evaluated by recording the catheterizations executed by interventional neuroradiologists according to a standard technique under fluoroscopy and conventional road-mapping independent of the fusion guidance. Precision of the fusion roadmap was evaluated by measuring (on a semiquantitative 3-point scale) the maximum offset between the position of the guidewires/catheters and the vasculature on the virtual CTA/MRA images. The targeted vessels were divided in 2 groups according to their position from the level of the aortic arch.

RESULTS: The average time needed for segmentation and image coregistration was 7 ± 2 minutes. The MRA/CTA virtual roadmap overlaid on live fluoroscopy was considered accurate in 84.8% (128/151) of the assessed landmarks, with a higher accuracy for the group of vessels closer to the aortic arch (92.4%; OR, 4.88; 95% CI, 1.83-11.66; P = .003).

CONCLUSIONS: Fluoroscopy with MRA/CTA fusion guidance for supra-aortic vessel interventions is feasible. Further improvements of the technique to increase accuracy at the cervical level and further studies are needed for assessing the procedural time savings and decreasing the x-ray radiation exposure.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Feddal A, Escalard S, Delvoye F, et al. Fusion Image Guidance for Supra-Aortic Vessel Catheterization in Neurointerventions: A Feasibility Study. AJNR Am J Neuroradiol. 2020. PMID: 32819903. doi:10.3174/ajnr.A6707

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。