三维心肌机械波测量:迈向在体三维心肌弹性成像
本研究在高端临床超声扫描仪上实现三维高帧率成像序列,门控4个连续心动周期时达820容积/秒,纳入5名健康志愿者和10例不同严重程度主动脉瓣狭窄患者,用杂波滤波波成像检测机械波并绘制左室三维弹性图。心房收缩期机械波可覆盖整个左室,其传播速度健康组1.6±0.2 m/s,患者组2.8±0.8 m/s(p=0.0016),速度与年龄、室间隔厚度及主动脉瓣峰值流速相关。
要点
- 心房收缩期机械波可提供左室全三维覆盖,是测量左室三维弹性图的关键时相。
- 主动脉瓣狭窄患者心房收缩期机械波传播速度高于健康志愿者(2.8±0.8 m/s vs 1.6±0.2 m/s,p=0.0016)。
- 机械波速度与年龄(健康组R²=0.88)、室间隔厚度(全组R²=0.73)及主动脉瓣峰值流速(R²=0.70)相关。
核心结论
- 本研究首次在健康志愿者和主动脉瓣狭窄患者中可视化并测量左室三维机械波速度,所提成像序列和测量技术实现了超声全时空三维左室弹性图测量。
研究设计与样本
- 在高端临床超声扫描仪上实现三维高帧率成像序列,门控4个连续心动周期时达820容积/秒。
- 纳入5名健康志愿者和10例不同严重程度主动脉瓣狭窄患者,评估可行性和可重复性。
- 采用杂波滤波波成像(Clutter Filter Wave Imaging)检测机械波,该法对自然机械波引起的微弱组织位移高度敏感。
- 试验注册号NCT03422770,参考标准包括心脏磁共振晚期钆增强。
关键影像表现/征象
- 所有受试者均获得三维机械波速度时空图。
- 仅心房收缩期特定机械波提供左室全三维覆盖。
- 10例患者中3例机械波速度较高者同时存在心脏磁共振晚期钆增强。
诊断标准与关键数值
- 心房收缩期机械波传播速度:健康志愿者1.6±0.2 m/s,主动脉瓣狭窄患者2.8±0.8 m/s(p=0.0016)。
- 机械波速度与年龄相关(R²=0.88,健康组)。
- 机械波速度与室间隔厚度相关(R²=0.73,全组)。
- 机械波速度与主动脉瓣峰值流速相关(R²=0.70)。
临床应用与阅片要点
- 日常超声检查中可尝试采集门控4个连续心动周期的三维高帧率数据,以心房收缩期机械波为测量时相。
- 采用杂波滤波波成像检测微弱组织位移,获取左室三维机械波速度时空图。
- 主动脉瓣狭窄患者机械波速度可能升高,3例患者高速度与心脏磁共振晚期钆增强共存,提示其可能与心肌纤维化相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to investigate the potential of a novel 3-dimensional (3D) mechanical wave velocity mapping technique, based on the natural mechanical waves produced by the heart itself, to approach a noninvasive 3D stiffness mapping of the left ventricle.
BACKGROUND: Myocardial fibrosis is recognized as a pathophysiological substrate of major cardiovascular disorders such as cardiomyopathies and valvular heart disease. As fibrosis leads to increased myocardial stiffness, ultrasound elastography measurements could provide important clinical information.
METHODS: A 3D high frame rate imaging sequence was implemented on a high-end clinical ultrasound scanner to achieve 820 volumes/s when gating over 4 consecutive cardiac cycles. Five healthy volunteers and 10 patients with various degrees of aortic stenosis were included to evaluate feasibility and reproducibility. Mechanical waves were detected using the novel Clutter Filter Wave Imaging approach, shown to be highly sensitive to the weak tissue displacements caused by natural mechanical waves.
RESULTS: 3D spatiotemporal maps of mechanical wave velocities were produced for all subjects. Only the specific mechanical wave at atrial contraction provided a full 3D coverage of the left ventricle (LV). The average atrial kick propagation velocity was 1.6 ± 0.2 m/s in healthy volunteers and 2.8 ± 0.8 m/s in patients (p = 0.0016). A high correlation was found between mechanical wave velocity and age (R2 = 0.88, healthy group), septal wall thickness (R2 = 0.73, entire group), and peak jet velocity across the aortic valve (R2 = 0.70). For 3 of the patients, the higher mechanical wave velocity coexisted with the presence of late gadolinium enhancement on cardiac magnetic resonance.
CONCLUSIONS: In this study, 3D LV mechanical wave velocities were visualized and measured in healthy volunteers and patients with aortic stenosis. The proposed imaging sequence and measurement technique allowed, for the first time, the measurement of full spatiotemporal 3D elasticity maps of the LV using ultrasound. (Ultrasonic markers for myocardial fibrosis and prognosis in aortic stenosis; NCT03422770).
引用
- Salles S, Espeland T, Molares A, et al. 3D Myocardial Mechanical Wave Measurements: Toward In Vivo 3D Myocardial Elasticity Mapping. JACC Cardiovasc Imaging. 2020. PMID: 32861651. doi:10.1016/j.jcmg.2020.05.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。