基于超声的容积计算机辅助诊断在正常胎儿心脏中的可靠性
研究纳入56例正常单胎胎儿,采集276个三维容积数据,用SonoVCAD自动显示8个胎儿超声心动图诊断切面。各切面成功率90.6%~99.6%,81.5%容积成功生成全部8个切面;观察者间kappa 0.439~0.933,观察者内kappa 0.602~0.903;专家用时少于两名低年资检查者(P<0.001),SonoVCAD用时显著少于二维超声(P<0.001)。
要点
- 8个诊断切面自动显示成功率均超90%,范围90.6%~99.6%。
- 81.5%(225/276)的容积可成功生成全部8个诊断切面。
- 观察者间与观察者内一致性为中等至近乎完美(kappa 0.439~0.933)。
诊断标准与关键数值
- 各诊断切面成功率均超过90%,范围90.6%~99.6%。
- 276个容积中81.5%(225/276)成功生成全部8个诊断切面。
- 两名低年资操作者间一致性中等至较佳(kappa 0.509~0.794)。
- 专家与两名低年资超声医生间一致性中等至近乎完美(kappa 0.439~0.933)。
- 观察者内可靠性较佳至近乎完美(kappa 0.602~0.903)。
临床应用与阅片要点
- 专家用时少于两名低年资检查者(P<0.001),两名低年资检查者间无显著差异(P=0.176)。
- SonoVCAD用时显著少于二维超声(P<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To explore the inter- and intra-observer reliability of Sonography-based Volume Computer Aided Diagnosis (SonoVCAD) in the display of 8 diagnostic planes of fetal echocardiography and to evaluate its efficiency.
METHODS: Three-dimensional volume data sets of the 56 normal singleton fetuses were acquired from a 4-chamber view by using a volume probe. After processing the data sets by using SonoVCAD, 8 cardiac diagnostic planes were displayed automatically. Three doctors with different experiences of performing fetal echocardiography evaluated each diagnostic plane and the success rates of 8 diagnostic planes were calculated. Inter-observer and intra-observer reliabilities were estimated by Cohen's kappa statistics.
RESULTS: A total of 276 volume data sets acquired from the 56 normal fetuses were used for SonoVCAD analysis and display. The success rate of each diagnostic section was more than 90%, ranging from 90.6% to 99.6%. Among 276 volumes, 81.5% (225/276) of volumes were able to generate all 8 diagnostic views successfully. Moderate to substantial agreement (kappa, 0.509-0.794) was found between 2 less experienced operators. Moderate to near-perfect agreement (kappa, 0.439-0.933) was found between an expert and 2 less experienced sonographers. Intra-observer reliability was substantial to near-perfect (kappa, 0.602-0.903). The efficiency of SonoVCAD was assessed. The expert spent less time than 2 less experienced examiners (P < 0.001) but no significant difference was found between 2 less experienced examiners (P = 0.176). Besides, SonoVCAD consumed significantly less time than 2-dimensional ultrasound (P < 0.001).
CONCLUSIONS: SonoVCAD can significantly improve the success rates of 8 diagnostic planes in fetal echocardiography with low operator dependency, good reproducibility and high efficiency.
引用
- Hu WY, Yu YC, Dai LY, et al. Reliability of Sonography-based Volume Computer Aided Diagnosis in the Normal Fetal Heart. J Ultrasound Med. 2020. PMID: 32856729. doi:10.1002/jum.15469
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。