文献速递骨肌胸部CT

利用常规计算机断层扫描检测胸腰椎椎体骨质疏松

Use of routine computed tomography scans for detecting osteoporosis in thoracolumbar vertebral bodies.
PubMed 文献 · Skeletal Radiol · 2020-08-07

本研究以定量计算机断层扫描(QCT)为参考,观察T10-L3椎体CT衰减值分布并推导预测骨质疏松和骨密度正常的Hounsfield单位(HU)阈值。共纳入482名受试者,最终测量457名参与者的2716个椎体,结果显示各层面椎体CT衰减值与体积骨密度(vBMD)强相关;识别骨密度正常的 optimal 阈值为>141 HU(敏感度93.5%,特异度86.1%),区分骨质疏松与骨量减少及骨密度正常的 optimal 阈值为<102.4 HU(特异度96.9%,敏感度82.1%)。

要点

  • 常规胸部CT矢状位重建结合椎体CT衰减值测量有助于预测高危人群的骨密度。
  • 识别骨密度正常的阈值为>141 HU,敏感度93.5%,特异度86.1%。
  • 区分骨质疏松与骨量减少及骨密度正常的阈值为<102.4 HU,特异度96.9%,敏感度82.1%。

核心结论

  • 常规胸部CT图像矢状位重建胸椎并结合脊柱CT衰减值测量,对预测高危人群的骨密度有价值。
  • 椎体压缩形态者的平均CT衰减值低于正常椎体形态者(108.9 ± 20.6 HU vs 136.8 ± 32.2 HU)。

研究设计与样本

  • 研究纳入2015年5月至2019年2月计划接受CT肺癌筛查和肺结节随访的482名受试者,扫描时背部下方放置校准体模进行胸部CT扫描。
  • 测量T10-L3椎体的体积骨密度(vBMD)和CT衰减值,分析两者相关性,并生成受试者工作特征(ROC)曲线确定诊断 optimal 阈值。
  • 排除筛选后最终测量457名参与者的2716个椎体。

关键影像表现/征象

  • 各层面椎体的CT衰减值与vBMD均显示强相关。
  • 压缩形态椎体的平均CT衰减值为108.9 ± 20.6 HU,正常形态椎体为136.8 ± 32.2 HU。

诊断标准与关键数值

  • 识别骨密度正常的 optimal 阈值为>141 HU,敏感度93.5%,特异度86.1%。
  • 区分骨质疏松与骨量减少及骨密度正常的 optimal 阈值为<102.4 HU,特异度96.9%,敏感度82.1%。

临床应用与阅片要点

  • 利用常规胸部CT矢状位重建胸椎并测量椎体CT衰减值,可辅助预测高危人群的骨密度。
  • 椎体压缩形态者的平均CT衰减值低于正常椎体形态者,阅片时可结合形态与衰减值综合评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study observed the distribution of CT attenuation values for T10-L3 vertebral bodies and derived the Hounsfield unit (HU) thresholds using the quantitative computed tomography (QCT) as a reference to predict osteoporosis and normal bone density.

METHODS: We included 482 subjects who were scheduled to undergo CT lung cancer screening and pulmonary nodule follow-up from May 2015 to February 2019. The subjects were scanned with the calibration phantom beneath the back while performing a chest CT scan. The volumetric bone mineral density (vBMD) and CT attenuation values of T10-L3 vertebral bodies were measured, and the correlation between the two measurements was analyzed. Receiver operator characteristic (ROC) curves were generated to determine diagnostic optimal thresholds.

RESULTS: A total of 2716 vertebral bodies of 457 participants were measured after exclusion screening. CT attenuation value of each plane's vertebral body showed a strong correlation with vBMD. The optimal threshold of > 141 HU was 93.5% sensitive and 86.1% specific for the recognition of normal BMD. The optimal threshold of < 102.4 HU was 96.9% specific and 82.1% sensitive for distinguishing osteoporosis from osteopenia and normal BMD. The average CT attenuation values of vertebral bodies with compressed and normal morphology were 108.9 ± 20.6 and 136.8 ± 32.2 HU, respectively.

CONCLUSION: Sagittal reconstruction of the thoracic vertebrae using routine thoracic CT image combined with CT attenuation value measurements of the spine is valuable for predicting bone mineral density in high-risk populations. The mean CT attenuation values of the vertebral bodies with vertebral compression appearance were lower than that of normal vertebral shape.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Wang P, She W, Mao Z, et al. Use of routine computed tomography scans for detecting osteoporosis in thoracolumbar vertebral bodies. Skeletal Radiol. 2020. PMID: 32767060. doi:10.1007/s00256-020-03573-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。