文献速递胸部技术与安全CTDR

冠状病毒病(COVID-19)的虚拟影像试验

Virtual Imaging Trials for Coronavirus Disease (COVID-19).
PubMed 文献 · AJR Am J Roentgenol · 2020-08-21

本研究开发了COVID-19患者计算模型,从20例确诊患者的CT图像分割病变形态并整合入XCAT模型,结合扫描仪专用CT和X线模拟器进行虚拟成像,证明虚拟影像试验可用于评估和优化COVID-19的CT与X线采集及分析工具,为COVID-19影像研究提供基础。

要点

  • 基于20例确诊COVID-19患者CT图像分割病变形态,构建了可模拟影像检查的计算模型。
  • 虚拟影像试验可结合扫描仪专用CT和X线模拟器,用于评估和优化COVID-19影像采集与分析工具。
  • 模拟病变在形状和纹理上主观上逼真,异常区域对比噪声比随mAs增加而升高。

关键影像表现/征象

  • 模拟的COVID-19异常在形状和纹理上主观上逼真。
  • 异常区域的对比噪声比在5、25和50 mAs图像上分别为1.6、3.0和3.6。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The virtual imaging trial is a unique framework that can greatly facilitate the assessment and optimization of imaging methods by emulating the imaging experiment using representative computational models of patients and validated imaging simulators. The purpose of this study was to show how virtual imaging trials can be adapted for imaging studies of coronavirus disease (COVID-19), enabling effective assessment and optimization of CT and radiography acquisitions and analysis tools for reliable imaging and management of COVID-19. MATERIALS AND METHODS. We developed the first computational models of patients with COVID-19 and as a proof of principle showed how they can be combined with imaging simulators for COVID-19 imaging studies. For the body habitus of the models, we used the 4D extended cardiac-torso (XCAT) model that was developed at Duke University. The morphologic features of COVID-19 abnormalities were segmented from 20 CT images of patients who had been confirmed to have COVID-19 and incorporated into XCAT models. Within a given disease area, the texture and material of the lung parenchyma in the XCAT were modified to match the properties observed in the clinical images. To show the utility, three developed COVID-19 computational phantoms were virtually imaged using a scanner-specific CT and radiography simulator. RESULTS. Subjectively, the simulated abnormalities were realistic in terms of shape and texture. Results showed that the contrast-to-noise ratios in the abnormal regions were 1.6, 3.0, and 3.6 for 5-, 25-, and 50-mAs images, respectively. CONCLUSION. The developed toolsets in this study provide the foundation for use of virtual imaging trials in effective assessment and optimization of CT and radiography acquisitions and analysis tools to help manage the COVID-19 pandemic.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Abadi E, Paul Segars W, Chalian H, et al. Virtual Imaging Trials for Coronavirus Disease (COVID-19). AJR Am J Roentgenol. 2020. PMID: 32822224. doi:10.2214/AJR.20.23429

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。