文献速递头颈神经MR

利用体素内不相干运动扩散加权MRI提高鉴别眼眶附件淋巴瘤与特发性眼眶炎症的诊断效能

Improving diagnostic performance of differentiating ocular adnexal lymphoma and idiopathic orbital inflammation using intravoxel incoherent motion diffusion-weighted MRI.
PubMed 文献 · Eur J Radiol · 2020-07-25

研究纳入21例眼眶附件淋巴瘤(OAL)和24例特发性眼眶炎症(IOI)患者,行体素内不相干运动扩散加权MRI(IVIM-DWI)测量ADC、D、D*和f。OAL的ADC、D和f低于IOI,D*无显著差异;D联合f的AUC(0.984)显著高于ADC(0.838),敏感度95.24%、特异度95.83%、准确率95.56%。结论认为IVIM-DWI有助于鉴别OAL与IOI,D联合f可提高鉴别诊断效能。

要点

  • OAL的ADC、D和f均低于IOI,D*在两组间无显著差异。
  • 鉴别OAL与IOI的最佳截断值:ADC 0.83×10-3 mm2/s、D 0.56×10-3 mm2/s、f 0.36×100%。
  • D联合f的AUC(0.984)显著高于ADC(0.838),敏感度95.24%、特异度95.83%、准确率95.56%。

关键影像表现/征象

  • OAL的ADC低于IOI(0.78±0.12 vs. 0.99±0.16×10-3 mm2/s,P<0.001)。
  • OAL的D低于IOI(0.34±0.15 vs. 0.76±0.25×10-3 mm2/s,P<0.001)。
  • OAL的f低于IOI(0.31±0.06 vs. 0.41±0.08×100%,P<0.001)。
  • D*在OAL与IOI间无显著差异(P=0.235)。

诊断标准与关键数值

  • 鉴别OAL与IOI的最佳截断值:ADC为0.83×10-3 mm2/s,D为0.56×10-3 mm2/s,f为0.36×100%。
  • ADC、D和f的AUC两两间无显著差异(均P>0.05)。
  • D联合f的AUC为0.984,显著高于ADC的0.838(Z=2.128,P=0.033)。
  • D联合f的敏感度为95.24%,特异度为95.83%,准确率为95.56%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the utility of intravoxel incoherent motion diffusion-weighted MRI (IVIM-DWI) derived diffusion and perfusion parameters in differentiating ocular adnexal lymphoma (OAL) from idiopathic orbital inflammation (IOI), and to assess whether IVIM-DWI provides improved diagnostic performance for the distinction.

METHOD: Twenty-one patients with OAL and 24 patients with IOI underwent IVIM-DWI. Apparent diffusion coefficient (ADC) and IVIM-DWI parameters including true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) were measured in lesions by two independent radiologists. The MRI parameter differences between OAL and IOI were tested using two-sample t-test. The receiver operating characteristic (ROC) analysis curves were used to determine the diagnostic performance of significant parameters for differentiation between OAL and IOI.

RESULTS: The ADC, D, and f were lower in OAL than those in IOI (ADC = 0.78 ± 0.12 vs. 0.99 ± 0.16 × 10-3 mm2/s, P < 0.001; D = 0.34 ± 0.15 vs. 0.76 ± 0.25 × 10-3 mm2/s, P < 0.001; f = 0.31 ± 0.06 vs. 0.41 ± 0.08 × 100 %, P < 0.001). There was no significant difference in D* between OAL and IOI (P = 0.235). The optimal cut-off values of ADC, D, and f in differentiating OAL from IOI were 0.83 × 10-3 mm2/s, 0.56 × 10-3 mm2/s, and 0.36 × 100 %, respectively. No significant differences were found in areas under the curve (AUCs) among ADC, D and f (all P > 0.05). The combination of D and f provided significantly higher AUC than ADC (AUC = 0.984 vs. 0.838, Z = 2.128, P = 0.033), and had higher sensitivity of 95.24 %, specificity of 95.83 %, and accuracy of 95.56 %.

CONCLUSIONS: IVIM-DWI is valuable in differentiating OAL from IOI, and D combined f can improve the performance of differential diagnosis.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Jiang H, Wang S, Li Z, et al. Improving diagnostic performance of differentiating ocular adnexal lymphoma and idiopathic orbital inflammation using intravoxel incoherent motion diffusion-weighted MRI. Eur J Radiol. 2020. PMID: 32745898. doi:10.1016/j.ejrad.2020.109191

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。