文献速递头颈神经MR

非平面回波扩散加权成像在甲状腺眼病检出、疾病监测与临床决策中的应用

Non-EPI-DWI for Detection, Disease Monitoring, and Clinical Decision-Making in Thyroid Eye Disease.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-01-01

回顾性纵向研究纳入31例甲状腺眼病患者,分析60次非平面回波扩散加权成像(非EPI-DWI)扫描的368条眼外肌,发现临床活动度评分(CAS)与ADC值呈显著正相关(rs=0.403;95%CI 0.312-0.489;P<.001),CAS≥3组ADC值显著高于CAS<3组(P<.001)。非EPI-DWI与CAS相关性良好,可作为CAS的辅助手段帮助临床决策,尤其在中等活动度和严重度的患者中。

要点

  • CAS与眼外肌非EPI-DWI的ADC值呈显著正相关(rs=0.403;95%CI 0.312-0.489;P<.001)。
  • CAS≥3组ADC值显著高于CAS<3组(P<.001),支持ADC用于活动度评估。
  • 非EPI-DWI对中等活动度和严重度甲状腺眼病患者的临床决策尤其有辅助价值。

核心结论

  • 非EPI-DWI与CAS相关性良好,是CAS之外辅助临床决策的有用工具,尤其在中等活动度和严重度的甲状腺眼病患者中。

研究设计与样本

  • 回顾性纵向研究,纳入5年间在多学科甲状腺眼病门诊就诊的31例患者,均有至少1次包含CAS的眼科和内分泌评估及非EPI-DWI ADC计算。
  • 共分析60次非EPI-DWI扫描的368条眼外肌,采用Spearman秩相关系数评估CAS与非EPI-DWI的关系,并构建患者流程图评估临床决策、生成受试者工作特征曲线。

关键影像表现/征象

  • 眼外肌ADC值在CAS≥3组显著高于CAS<3组(P<.001)。

诊断标准与关键数值

  • CAS与ADC呈显著正相关(rs=0.403;95%CI 0.312-0.489;P<.001)。
  • CAS≥3组与CAS<3组比较,ADC值差异有统计学意义(P<.001)。

临床应用与阅片要点

  • 非EPI-DWI可作为CAS的辅助手段用于甲状腺眼病的临床决策,尤其适用于中等活动度和严重度的患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The Clinical Activity Score is widely used to grade activity of thyroid eye disease and guide treatment decisions, but as a subjective measurement and being confined to the anterior orbit, it has limitations. Non-EPI-DWI of the extraocular muscles may offer advantages as a functional imaging technique with reduced skull base artifacts, but the correlation with the Clinical Activity Score and patient outcome is unknown. Our aim was to establish the correlation between the Clinical Activity Score and non-EPI-DWI and to describe the additional value provided by adjunctive non-EPI-DWI in making clinical decisions.

MATERIALS AND METHODS: This was a retrospective longitudinal study of 31 patients seen in a multidisciplinary thyroid eye disease clinic during 5 years who had at least 1 ophthalmic and endocrine assessment including the Clinical Activity Score and a non-EPI-DWI ADC calculation. The Spearman rank correlation coefficient was used to determine the relationship between the Clinical Activity Score and non-EPI-DWI. A patient flow chart was constructed to evaluate clinical decision-making, and receiver operating characteristics were generated.

RESULTS: From 60 non-EPI-DWI scans, 368 extraocular muscles were selected for analysis. There was a significant positive correlation between the Clinical Activity Score and ADC (r s = 0.403; 95% CI, 0.312-0.489; P < .001). ADC values were significantly higher in the Clinical Activity Score ≥ 3 group compared with the Clinical Activity Score < 3 group (P < .001). Our patient flow chart identified a third intermediate-severity cohort in which the non-EPI-DWI was particularly useful in guiding clinical decisions.

CONCLUSIONS: The non-EPI-DWI correlated well with the Clinical Activity Score in our patients and was a useful adjunct to the Clinical Activity Score in making clinical decisions, especially in patients with intermediate activity and severity of thyroid eye disease.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Feeney C, Lingam RK, Lee V, et al. Non-EPI-DWI for Detection, Disease Monitoring, and Clinical Decision-Making in Thyroid Eye Disease. AJNR Am J Neuroradiol. 2020. PMID: 32796099. doi:10.3174/ajnr.A6664

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。