文献速递神经头颈外周血管MRDSA

薄层MR成像诊断颈动脉海绵窦瘘

Thin-Section MR Imaging for Carotid Cavernous Fistula.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-08-20

本回顾性研究纳入98例临床疑似颈动脉海绵窦瘘患者,以DSA为参考标准评估薄层MR成像的诊断效能。薄层MR成像总体准确率88.8%、敏感度97.4%、特异度83.3%,并识别出海绵窦轮廓异常、海绵窦内信号流空、静脉引流显著及眶周软组织肿胀等影像预测因素。

要点

  • 薄层MR成像诊断颈动脉海绵窦瘘敏感度97.4%、特异度83.3%、准确率88.8%。
  • 海绵窦轮廓异常(OR 21.7)、海绵窦内信号流空(OR 15.3)为可能的影像预测因素。
  • 静脉引流显著(OR 54.0)、眶周软组织肿胀(OR 40.4)亦为可能的影像预测因素。

核心结论

  • 薄层MR成像在临床疑似颈动脉海绵窦瘘患者中具有高诊断效能,并可提供可能的影像预测因素,其扫描方案可能有助于决定适当的管理计划。

研究设计与样本

  • 回顾性研究,纳入2006年1月至2018年9月间临床疑似颈动脉海绵窦瘘的98例患者,均行治疗前薄层MR成像和DSA,以DSA为参考标准。

关键影像表现/征象

  • 薄层MR成像包括2D冠状位T1WI和T2WI(层厚3 mm)及3D增强T1WI(层厚0.6 mm);可能的影像预测因素包括海绵窦轮廓异常、海绵窦内信号流空、静脉引流显著、眶周软组织肿胀。

诊断标准与关键数值

  • 薄层MR成像诊断颈动脉海绵窦瘘的总体准确率88.8%、敏感度97.4%、特异度83.3%,以DSA为参考标准。

临床应用与阅片要点

  • 作者认为薄层MR成像方案可能有助于决定临床疑似颈动脉海绵窦瘘患者的适当管理计划。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Carotid-cavernous fistulas are abnormal vascular shunts that can cause various neurologic or orbital symptoms. The purpose of this retrospective study was to evaluate the diagnostic performance of thin-section MR imaging for carotid cavernous fistula in patients with clinically suspected carotid cavernous fistula, and to identify possible imaging predictors of carotid cavernous fistula.

MATERIALS AND METHODS: A total of 98 patients who were clinically suspected of having carotid cavernous fistula (according to their symptoms and physical examinations) between January 2006 and September 2018 were included in this study. The patients underwent pretreatment thin-section MR imaging and DSA. Thin-section MR imaging consisted of 2D coronal T1- and T2WI with 3-mm thickness and 3D contrast-enhanced T1WI with 0.6 mm thickness. The diagnostic performance of thin-section MR imaging for carotid cavernous fistula was evaluated with the reference standard of DSA. Univariate logistic regression analysis was performed to determine possible imaging predictors of carotid cavernous fistula.

RESULTS: Among the 98 patients, DSA confirmed 38 as having carotid cavernous fistula. The overall accuracy, sensitivity, and specificity of thin-section MR imaging were 88.8%, 97.4%, and 83.3%, respectively. Possible imaging predictors on thin-section MR imaging included abnormal contour of the cavernous sinus (OR: 21.7), internal signal void of the cavernous sinus (OR: 15.3), prominent venous drainage flow (OR: 54.0), and orbital/periorbital soft tissue swelling (OR: 40.4).

CONCLUSIONS: Thin-section MR imaging provides high diagnostic performance and possible imaging predictors of carotid cavernous fistula in patients with clinically suspected carotid cavernous fistula. Thin-section MR imaging protocols could help decide appropriate management plans for patients with clinically suspected carotid cavernous fistula.