文献速递神经MR

在3特斯拉下采用基于减影的磁共振血管造影中的径向采集逐点编码时间缩短技术评估囊状未破裂颅内动脉瘤

Pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography to assess saccular unruptured intracranial aneurysms at 3 Tesla.
PubMed 文献 · Neuroradiology · 2020-08-13

本研究纳入49例经TOF-MRA识别的54个囊状未破裂颅内动脉瘤,比较PETRA-MRA与TOF-MRA的形态学参数、对比噪声比、锐利度、主观评分及噪声。结果显示PETRA-MRA可检出全部动脉瘤,锐利度和主观评分显著高于TOF-MRA,噪声更低,形态学参数与CTA更相关。

要点

  • PETRA-MRA可检出全部54个囊状未破裂颅内动脉瘤,形态学参数与CTA相关性优于TOF-MRA。
  • PETRA-MRA的锐利度和主观图像评分显著高于TOF-MRA(p<0.001),观察者间一致性均优。
  • PETRA-MRA噪声水平显著低于TOF-MRA(59 vs. 73 dB,p<0.01)。

关键影像表现/征象

  • PETRA-MRA检出全部54个囊状未破裂颅内动脉瘤。
  • 15例患者的形态学参数中,PETRA-MRA与CTA的相关性优于TOF-MRA。
  • 54个动脉瘤中,除流入角外(p<0.05),PETRA-MRA与TOF-MRA参数无显著差异(p>0.10)。
  • 4例有流入角的患者中,PETRA-MRA测得的流入角与DSA的相关性优于TOF-MRA。
  • PETRA-MRA的锐利度和主观图像评分显著高于TOF-MRA(p<0.001)。

诊断标准与关键数值

  • 主观图像评分采用4分制:4分为优,3分为良,2分为差,1分为不可评估。
  • PETRA-MRA与TOF-MRA的对比噪声比相当(p=0.068)。
  • 观察者间一致性:PETRA-MRA的组内相关系数为0.90,TOF-MRA为0.97。
  • PETRA-MRA噪声水平显著低于TOF-MRA(59 vs. 73 dB,p<0.01)。

临床应用与阅片要点

  • PETRA-MRA可检出全部囊状未破裂颅内动脉瘤,且主观评分和锐利度优于TOF-MRA,噪声更低。
  • 在评估动脉瘤形态学参数(如流入角)时,PETRA-MRA与CTA和DSA的相关性优于TOF-MRA。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the clinical utility of pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography (PETRA-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA) to evaluate saccular unruptured intracranial aneurysms (UIAs).

METHODS: A total of 49 patients with 54 TOF-MRA-identified saccular UIAs were enrolled. The morphologic parameters, contrast-to-noise-ratios (CNRs), and sharpness of aneurysms were measured using PETRA-MRA and TOF-MRA. Two radiologists independently evaluated subjective image scores, focusing on aneurysm signal homogeneities and sharpness depictions using a 4-point scale: 4, excellent; 3, good; 2, poor; 1, not assessable. PETRA-MRA and TOF-MRA acoustic noises were measured.

RESULTS: All aneurysms were detected with PETRA-MRA. The morphologic parameters of 15 patients evaluated with PETRA-MRA were more closely correlated with those receiving computed tomography angiography over those receiving TOF-MRA. No significant differences between PETRA-MRA and TOF-MRA parameters were seen in the 54 UIAs (p > 0.10), excluding those with inflow angles (p < 0.05). In four patients with inflow angles on PETRA-MRA, the angles were more closely related to those of digital subtraction angiography than those of TOF-MRA. CNRs between TOF-MRA and PETRA-MRA were comparable (p = 0.068), and PETRA-MRA sharpness values and subjective image scores were significantly higher than those of TOF-MRA (p < 0.001). Inter-observer agreements were excellent for both PETRA-MRA and TOF-MRA (intraclass correlation coefficients were 0.90 and 0.97, respectively). The acoustic noise levels of PETRA-MRA were much lower than those of TOF-MRA (59 vs.73 dB, p < 0.01).

CONCLUSIONS: PETRA-MRA, with better visualization of aneurysms and lower acoustic noise levels than TOF-MRA, showed a superior diagnostic performance for depicting saccular UIAs.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Fu Q, Liu DX, Zhang XY, et al. Pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography to assess saccular unruptured intracranial aneurysms at 3 Tesla. Neuroradiology. 2020. PMID: 32794074. doi:10.1007/s00234-020-02512-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。