压缩感知对比增强高分辨率颅内血管壁MRI与常规T1各向同性涡轮自旋回波采集序列的比较
回顾性纳入72例同时行VISTA-CS与VISTA-nonCS颅内血管壁MRI的患者,比较图像质量与定量指标。VISTA-CS扫描覆盖前后循环且扫描时间略短(约7分钟 vs 8分钟),SNR更高或呈更高趋势,正常部位CNR无显著差异,但病灶部位CNR较低,主观管壁勾画VISTA-nonCS更优,总体图像质量及可接受图像比例无显著差异。作者认为CS可能有用。
要点
- VISTA-CS扫描覆盖前后循环,扫描时间约7分钟,略短于VISTA-nonCS的约8分钟。
- 正常部位CNR两种序列无显著差异(p=0.907),病灶部位VISTA-CS的CNR低于VISTA-nonCS(p=0.003)。
- 主观管壁勾画VISTA-nonCS优于VISTA-CS(p=0.019),总体图像质量无显著差异(p=0.297)。
核心结论
- 压缩感知可能对颅内血管壁MRI有用,因其可在不损害图像质量的情况下实现更大扫描覆盖并略缩短扫描时间。
研究设计与样本
- 回顾性纳入2017年4月至2018年7月72例同时行VISTA-CS与VISTA-nonCS颅内血管壁MRI的患者。
- 比较两种序列的管壁体积、管腔体积、SNR、CNR,并由两名神经放射科医师独立以四点量表评估总体图像质量及正常与病灶管壁勾画程度(评分≥3定义为可接受)。
关键影像表现/征象
- VISTA-CS扫描覆盖增加至覆盖前循环和后循环,扫描时间约7分钟,VISTA-nonCS约8分钟。
- VISTA-CS与VISTA-nonCS的管壁体积和管腔体积无显著差异(组内相关系数=0.964-0.997)。
- VISTA-CS的SNR高于或呈高于VISTA-nonCS的趋势。
- 正常部位CNR两种序列无显著差异(p=0.907),病灶部位VISTA-CS的CNR低于VISTA-nonCS(p=0.003)。
- 主观管壁勾画VISTA-nonCS优于VISTA-CS(p=0.019),总体图像质量无显著差异(p=0.297)。
诊断标准与关键数值
- 主观评估采用四点量表,评分≥3定义为可接受。
- 可接受图像比例VISTA-CS为83.3-97.8%,VISTA-nonCS为75-100%,两者无显著差异。
临床应用与阅片要点
- VISTA-CS可覆盖前后循环且扫描时间略短,但病灶部位CNR较低、主观管壁勾画不如VISTA-nonCS。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Compressed sensing (CS) has gained wide interest since it accelerates MRI acquisition. We aimed to compare the 3D post-contrast T1-weighted volumetric isotropic turbo spin echo acquisition (VISTA) with CS (VISTA-CS) and without CS (VISTA-nonCS) in intracranial vessel wall MRIs (VW-MRI).
MATERIALS AND METHODS: From April 2017 to July 2018, 72 patients who underwent VW-MRI, including both VISTA-CS and VISTA-nonCS, were retrospectively enrolled. Wall and lumen volumes, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured from normal and lesion sites. Two neuroradiologists independently evaluated overall image quality and degree of normal and lesion wall delineation with a four-point scale (scores ≥ 3 defined as acceptable).
RESULTS: Scan coverage was increased in VISTA-CS to cover both anterior and posterior circulations with a slightly shorter scan time compared to VISTA-nonCS (approximately 7 minutes vs. 8 minutes). Wall and lumen volumes were not significantly different with VISTA-CS or VISTA-nonCS (interclass correlation coefficient = 0.964-0.997). SNR was or trended towards significantly higher values in VISTA-CS than in VISTA-nonCS. At normal sites, CNR was not significantly different between two sequences (p = 0.907), whereas VISTA-CS provided lower CNR in lesion sites compared with VISTA-nonCS (p = 0.003). Subjective wall delineation was superior with VISTA-nonCS than with VISTA-CS (p = 0.019), although overall image quality did not differ (p = 0.297). The proportions of images with acceptable quality were not significantly different between VISTA-CS (83.3-97.8%) and VISTA-nonCS (75-100%).
CONCLUSION: CS may be useful for intracranial VW-MRI as it allows for larger scan coverage with slightly shorter scan time without compromising image quality.
引用
- Park CJ, Cha J, Ahn SS, et al. Contrast-Enhanced High-Resolution Intracranial Vessel Wall MRI with Compressed Sensing: Comparison with Conventional T1 Volumetric Isotropic Turbo Spin Echo Acquisition Sequence. Korean J Radiol. 2020. PMID: 32767865. doi:10.3348/kjr.2020.0128
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。