文献速递神经外周血管MR

采用策略性采集梯度回波(STAGE)与血管壁MR评估的大脑中动脉斑块特征与颅内动脉粥样硬化患者下游低灌注相关

Plaque characteristics of middle cerebral artery assessed using strategically acquired gradient echo (STAGE) and vessel wall MR contribute to misery downstream perfusion in patients with intracranial atherosclerosis.
PubMed 文献 · Eur Radiol · 2020-08-01

本研究纳入91例单侧大脑中动脉粥样硬化斑块患者,行STAGE与高分辨率血管壁MRI(hr-vwMRI),以MTT-ASPECTS阈值6分为界分为低灌注组与无低灌注组,比较斑块特征。结果显示STAGE检测易损斑块效率良好;斑块高磁敏感性与高狭窄度是下游低灌注的独立预测因子,两者联合AUC为0.900。

要点

  • STAGE检测大脑中动脉易损斑块与hr-vwMRI参考标准相比效率良好。
  • 斑块磁敏感性增高与管腔狭窄度增高是下游低灌注的独立预测因子。
  • STAGE所测斑块磁敏感性联合hr-vwMRI斑块特征对预测低灌注有增量价值。

关键影像表现/征象

  • 低灌注组内腔面积(IWA)更小、狭窄程度更高、表面更不规则、斑块内高信号(HIP)更多、强化等级更高、磁敏感性更高(均p < 0.01)。
  • 斑块磁敏感性更高与狭窄程度更高是下游低灌注发生的独立预测因子(p = 0.025,p = 0.048)。
  • 两变量联合的AUC为0.900。

诊断标准与关键数值

  • 以hr-vwMRI为参考标准,STAGE检测易损斑块效率良好。
  • 斑块磁敏感性与狭窄程度联合预测下游低灌注的AUC为0.900。
  • 低灌注分组采用MTT-ASPECTS阈值6分。

临床应用与阅片要点

  • 阅片时可结合STAGE所测斑块磁敏感性与hr-vwMRI所测狭窄程度评估下游低灌注风险。
  • STAGE可在常规hr-vwMRI基础上提供斑块易损性增量信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess plaque vulnerability of the middle cerebral artery (MCA) using strategically acquired gradient echo (STAGE) versus high-resolution vessel wall MRI (hr-vwMRI), and explore the relationship between plaque characteristics and misery downstream perfusion.

METHODS: Ninety-one patients with single MCA atherosclerotic plaques underwent STAGE and hr-vwMRI were categorized into a group with misery perfusion and a group without based on the Alberta Stroke Program Early CT score (MTT-ASPECTS) with a threshold of 6. Plaque characteristics including inner lumen area (IWA), susceptibility, presence of hyperintensity within plaque (HIP), surface irregularity, stenosis degree, remodeling index, lipid ratio, and enhancement grade were compared between the two groups. The vulnerability of each plaque was retrospectively assessed on both STAGE and hr-vwMRI according to the combination of plaque features. Logistic regression analysis and ROC curve were performed to evaluate the effect of plaque characteristics on the presence of misery perfusion.

RESULTS: Taking hr-vwMRI as the reference, STAGE showed good efficiency in detecting vulnerable plaques. Patients with misery perfusion had less IWA, higher stenosis degree, more irregular surface and HIP, higher enhancement grade, and susceptibility (p < 0.01 for all). Higher susceptibility and stenosis degree were independent predictors for the occurrence of misery perfusion (p = 0.025, p = 0.048). The AUC was 0.900 for the combination of the two variables.

CONCLUSION: STAGE shows good efficiency to assess MCA plaque vulnerability versus hr-vwMRI. Plaque susceptibility evaluated using STAGE provides incremental value to predict misery perfusion combined with hr-vwMRI plaque features.

KEY POINTS: • STAGE has good efficiency in evaluating MCA plaque vulnerability versus hr-vwMRI. • Higher plaque susceptibility assessed using STAGE and higher grade luminal stenosis based on hr-vwMRI attribute to misery downstream perfusion. • STAGE provides incremental value on the understanding of plaque vulnerability in addition to conventional hr-vwMRI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang T, Tang R, Liu S, et al. Plaque characteristics of middle cerebral artery assessed using strategically acquired gradient echo (STAGE) and vessel wall MR contribute to misery downstream perfusion in patients with intracranial atherosclerosis. Eur Radiol. 2020. PMID: 32740814. doi:10.1007/s00330-020-07055-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。